catalogue search
|
You may also be interested in
Busbar, Gantry, Rubber tired gantry, Crane, Cable trolley
Text version of the page
1912
Insulated conductor system U20, U30, U40 - 19699 ACCESSORIES FOR U 40Transfer guideTransfer guides are used for transfer or power-interrupting applications.Max. vertical and horizontal offset: ±6 mm, max. air gap: 12 mm UTI 40 are transfer buttons (bellmouth shaped conductor ends) withintegrated isolating piece. They are factory assembled to layout plans.For separate ordering indicate conductor length and size.max 13030 center ofhanger w/o cond. UTI0.014 134 910 Isolating sectionsType M:Factory assembled per system layoutType L:Loose, including two locking pins 4 x 8Position of isolating sections per system layout. Use one extrahanger each side, max. 400 mm away for stability.Rails & hangers to be ordered separately. TypeWeight kgCat.-No.250w/o cond. 250A250 max. 400max. 400 min. 250 Feed terminal max. 400max. 400 To avoid voltage by-pass by carbon brushes and to separate maintenance bays, control and main feed sections, double isolating sectionsare recommended.Dim. Adepends on type and number of current collectors and stopping distance of the crane. TypeWeight kgCat.-No. TypeWeight kgCat.-No. IT/U 40/200 C-M 0.104135 176 IT/U 40/200 C-L 0.104134 210 IT/U 40/300 C-M 0.104134 790 IT/U 40/300 C-L 0.104134 220 IT/U 40/300 CH-M 0.104135 187 IT/U 40/300 CH-L 0.104134 230 IT/U 40/400 C-M 0.104134 800 IT/U 40/400 C-L 0.104134 250 IT/U 40 400 CH-M 0.104135 188 IT/U 40 400 CH-L 0.104134 260 IT/U 40/500 C-M 0.104134 810 IT/U 40/500 C-L 0.104134 270 IT/U 40/500 CH-M 0.104134 820 IT/U 40/500 CH-L 0.104134 370 IT/U 40/500 CHH-M 0.104135 378 IT/U 40/500 CHH-L 0.104134 38038 |