ÍJLA insulated conductors u 30
horizontal curve
Type
U 30/120 CE
U 30/75 C
U 30/100 C
Weight kg/m | 1.440
Standard shrouding, color green
1.100
130 28 • 130 29 •
130 30 • 130 31 •
1.360
130 32 • 130 33 •
130 34 • 130 35 •
130 24 ■ 130 25 ■
Cat.-No. phase * Cat.-No. ground :
High temperature shrouding, color grey
Cat.-No. phase * Cat.-No. ground
130 26 ■ 130 27 ■
Type
U 30/130 CH
U 30/150 C
U 30/200 C
U 30/200 CH
Weight kg/m | 1.540
Standard shrouding, color green
1.780
130 40 130 41
130 42 130 43
2.180
130 44 • 130 45 •
130 46 • 130 47 •
2.180
130 48 • 130 49 •
130 50 • 130 51 •
130 36 130 37
Cat.-No. phase * Cat.-No. ground
High temperature shrouding, color grey
Cat.-No. phase * Cat.-No. ground
130 38 130 39
Engineering data
Type
Conductor c m
;ross section m2
Leakage distance of shroud mm
max. voltage
max. continuous ampere capacity Aat 35° C
Resistance (R) Ohm/1000 m
Impedance Ohm/ 1000 m based on 50 Hz &80 mm cond. spacing
Copper
Steel
U 30/120 CE
100
18
100
1000
330
0.178
0.222
U 30/ 75 C
75
100
1000
280
0.238
0.280
U 30/100 C
100
105
1000
330
0.178
0.264
U 30/130 CH
130
95
1000
400
0.137
0.221
U 30/150 C
150
95
1000
440
0.126
0.219
U 30/200 C
200
90
1000
530
0.090
0.195
U 30/200 CH
200
90
1000
530
0.090
0.195
Conductor Code:
U = Insulated Conductors
30 = Shroud Size
75-225 = Conductor Cross Sectional
Area (mm2) CE = Copper/stainless steel conductor C = Copper conductor
CH = Copper conductor with extra
deep groove for high speed
applications
Application:
for indoor and outdoor Supply length:
6 m standard
Shorter lenghts are available.
Bending:
factory fabricated on request
Support spacing:
- for straight runs and lateral curves: 1500 mm
- for horizontal curves RH < 10 m: 750 mm
- for horizontal curves RH > 10 m: 1500 mm
Heating system:
The conductor Type U 30/75 C can be equipped
with heating cable for icing conditions.
See page 4 for chemical and electrical properties.
24
Add last number (1, 2, 3, 4, 5 or 6 m length suffix) in accordance to bars required.

pageCatalog pdf di En 2012-02-07-16