| | | ÍJLA insulated conductors u 30 | | |
| | | |
| | | horizontal curve | | |
| | | |
| | | Type | | |
| | | U 30/120 CE | | U 30/75 C | | U 30/100 C | | |
| | | |
| | | |
| | | Weight kg/m | 1.440 Standard shrouding, color green | | |
| | | 1.100 130 28 • 130 29 • 130 30 • 130 31 • | | 1.360 130 32 • 130 33 • 130 34 • 130 35 • | | |
| | | |
| | | 130 24 ■ 130 25 ■ | | |
| | | Cat.-No. phase * Cat.-No. ground : | | |
| | | |
| | | |
| | | High temperature shrouding, color grey | | |
| | | |
| | | Cat.-No. phase * Cat.-No. ground | | 130 26 ■ 130 27 ■ | | |
| | | |
| | | |
| | | Type | | |
| | | U 30/130 CH | | U 30/150 C | | U 30/200 C | | U 30/200 CH | | |
| | | |
| | | |
| | | Weight kg/m | 1.540 Standard shrouding, color green | | |
| | | 1.780 130 40 130 41 130 42 130 43 | | 2.180 130 44 • 130 45 • 130 46 • 130 47 • | | 2.180 130 48 • 130 49 • 130 50 • 130 51 • | | |
| | | |
| | | 130 36 130 37 | | |
| | | Cat.-No. phase * Cat.-No. ground | | |
| | | |
| | | |
| | | High temperature shrouding, color grey | | |
| | | |
| | | Cat.-No. phase * Cat.-No. ground | | |
| | | 130 38 130 39 | | |
| | | |
| | | |
| | | Engineering data | | |
| | | |
| | | | | | | | | | | | | | | | Type | Conductor c m | ;ross section m2 | Leakage distance of shroud mm | max. voltage | max. continuous ampere capacity Aat 35° C | Resistance (R) Ohm/1000 m | Impedance Ohm/ 1000 m based on 50 Hz &80 mm cond. spacing | | | | Copper | Steel | | | | U 30/120 CE | 100 | 18 | 100 | 1000 | 330 | 0.178 | 0.222 | | | | U 30/ 75 C | 75 | | 100 | 1000 | 280 | 0.238 | 0.280 | | | | U 30/100 C | 100 | | 105 | 1000 | 330 | 0.178 | 0.264 | | | | U 30/130 CH | 130 | | 95 | 1000 | 400 | 0.137 | 0.221 | | | | U 30/150 C | 150 | | 95 | 1000 | 440 | 0.126 | 0.219 | | | | U 30/200 C | 200 | | 90 | 1000 | 530 | 0.090 | 0.195 | | | | U 30/200 CH | 200 | | 90 | 1000 | 530 | 0.090 | 0.195 | | | | | | | | | | | | | | | |
| | | |
| | | Conductor Code: U = Insulated Conductors 30 = Shroud Size 75-225 = Conductor Cross Sectional Area (mm2) CE = Copper/stainless steel conductor C = Copper conductor CH = Copper conductor with extra deep groove for high speed applications | | Application: for indoor and outdoor Supply length: 6 m standard Shorter lenghts are available. Bending: factory fabricated on request | | Support spacing: - for straight runs and lateral curves: 1500 mm - for horizontal curves RH < 10 m: 750 mm - for horizontal curves RH > 10 m: 1500 mm Heating system: The conductor Type U 30/75 C can be equipped with heating cable for icing conditions. See page 4 for chemical and electrical properties. | | |
| | | |
| | | |
| | | |
| | | 24 | | |
| | | Add last number (1, 2, 3, 4, 5 or 6 m length suffix) in accordance to bars required. | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |