GENERAL INSTALLATION INSTRUCTIONS
1912 â– â– Install AGV-collectors on vehicle with bristle
industrial cleaning brushes in direction of travel. â– â– Install AGV-Base Plate on top of the floor â– â– The >
*
marked height 68 (65, 45) of AGV-Collectors type BLS is the dimensionat contact position. Allowable tolerance: + 2 mm.In order to guarantee sufficient contact pressure the max. wear reduction of the contactbrushes is limited to 5 mm whereby the unevenness of the floor must be considered. â– â– Between base plate and cutout at concrete floor a dust- and waterproof sealing has to
be installed. >
Example of installation BLS 200-2-01 with BLK 200-2-01 * >
consider unevenness of Floor when setting clearance for contact industrial brushes–·–install sealing at concrete cutout.In accordance with our company’s policy of continued improvement, we reserve the right to amend specifications and details at any time. 7