ALUMINIUM ENCLOSED CONDUCTOR SYSTEMS
INDEX
Page
Page
Powerail versions (Photos)
2
Transfer Guides, oblique cut
15
Technical Data
2
Heating System
16
Basic Description
3
Anti-condensation Sections
17
Powerail Cat.-Nos. and Weights
4
Telescope Sections
18
Engineering Data and Configurations
5
Expansion Joint Sections
19
Standard Sections & Curves
6
Collectors
20
Joint Material
7
Double Collectors
21
Brackets
8
Tow Arms
22
Hangers
9
Flexible Tow Arm Configurations
23
End Caps
10
Sectionalizing
24
End Feeds
10
Spare Parts
24
Line Feeds
11
Examples for ordering
26, 27
Contact sections, Turntables, Switches
12
Basic Dimensions
28
Transfer Funnels
13
Questionnaire
29, 30
Transfer Guides, straight cut
14
Application Photos
25, 37, 31
Type LSV
Type LSV with Plastic shielding "FP"
Type LSVG
Type LSVG with sealing strip "D"
TECHNICAL DATA
Ampacity : 300 A max.
Voltage : 600 V max.
Collector rating : 40 A & multiple
min. Bending Radius : LSV 1000 mm/ LSVG 1500 mm
Temperature Resistance:
Powerail - 40° C/+100° C
Sealing strip "D" up to + 80° C Plastic shielding "FP" up to + 55° C Collector - 40°C/+ 70° C*
16
25
35
50
70
mm2 copper
Impedance:
1.17 0.72 0.53 0.38 0.28 Ohm/1000 m
16
25
35
50
70 mm2 copper
Resistance:
1.16 0.71 0.51 0.36 0.26 Ohm/1000 m
2
* Consult factory for higher temperature applications.

pageCatalog pdf di En 2012-06-22-01