Catalogue United Electric Controls Short Form Catalog
www.ueonline.com
print switch display
Page / 20
United Electric Controls - 145239, 80587, 16296, 2626
/ 20
See all the products United Electric Controls
Text version of the page
U.S. SALES OFFICES
United Electric Controls 31 Old Stage Road Hampton Falls, NH 03844 Phone: 617-899-1132
email: northeastsales@ueonline.com
United Electric Controls 28 N. Wise Ave. Freeport, IL 61032 Phone: 815-341-2588
email: midwestsales@ueonline.com
United Electric Controls 1022 Vineyard Drive Conyers, GA 30013
Phone: 770-335-9802
email: southeastsales@ueonline.com
United Electric Controls 5829 Grazing Court
Mason, OH 45040
Phone: 513-535-5486
email: midatlanticsales@ueonline.com
United Electric Controls 102 Salazar Court Clayton, CA 94517
Phone: 925-408-5997
email: westcoastsales@ueonline.com
United Electric Controls 27 Summit Terrace Sparta, NJ 07871
Phone: 973-271-2550
email: easternsales@ueonline.com United Electric Controls
4306 Whickham Drive
Fulshear, TX 77441 Phone: 832-457-6138
email: southwestsales@ueonline.com
United Electric Controls 5201 Arbor Court Odessa, TX 79762 Phone: 432-770-4164
email: westtexassales@ueonline.com
DIVISIONS
Applied Sensor Technologies 180 Dexter Avenue, P.O. Box 9143 Watertown, MA 02471-9143 Telephone: 617-923-6966 Fax: 617-926-8411 www.appliedsensortech.com
Precision Sensors 50 Seemans Lane Milford, CT 06460 Phone: 203-877-2795 Fax: 203-877-8752 www.precisionsensors.com
INTERNATIONAL OFFICES
CHINA
United Electric Controls
Room 1011, 10th Flr,
Huai Hai Zhonghua Building
No. 885, Renmin Road, Luwan District
Shanghai 200010, P.R. China
Phone: +8621-6255 8059
email: chinasales@ueonline.com
EASTERN EUROPE & SCANDINAVIA
United Electric Controls 05-806 Komorow Kujawska 5, Poland
Phone: +48 22 499 4804
email: easterneuropesales@ueonline.com
GERMANY
United Electric Controls An Der Zentlinde 21 D-64711 Erbach, Germany
Phone: 496-062-7400
email: europeansales@ueonline.com
INDIA
United Electric Controls House no. 7, Kamalkunj Society Nizampura,
Baraoda (Gujarat), India
Phone: +91-265-2788654
email: indiasales@ueonline.com
ASIA-PACIFIC
United Electric Controls, Far East No. 1-2-2, 2nd Floor
Jalan 4/101C
Cheras Business Centre
Batu 5, Jalan Cheras
56100 Kuala Lumpur, Malaysia
Phone: 603-9133-4122
email: fareastsales@ueonline.com
MEXICO
United Electric Controls Andador Austria 102 Fracc. Petroquimica CP 89365 Tampico, Tamaulipas Mexico
Phone: 833-132-3726
email: latinamericasales@ueonline.com
RUSSIA
United Electric Controls, Moscow Kuusinena str., 19A, Office 310 Moscow, 125252, Russia Phone: +7 (095) 792-88-06 email: russiansales@ueonline.com
CANADA
EASTERN
68 Mosley Crescent Brampton, Ontario
Canada L6Y 5C8
Phone: 905-455-5131 FAX: 905-455-5131
WESTERN
148 Silver Ridge Close N.W.
Calgary, Alberta
Canada T3B 3T4 Phone: 403-247-3724 FAX: 403-247-3724
RECOMMENDED PRACTICES AND WARNINGS
United Electric Controls Company recommends careful consideration of the following factors when specifying and installing UE pressure and temperature units. Before installing a unit, the Installation and Maintenance instructions provided with unit must be read and understood.
• To avoid damaging unit, proof pressure and maximum temperature limits stated in literature and on nameplates must never be exceeded, even by surges in the system. Operation of the unit up to maximum pressure or temperature is acceptable on a limited basis (e.g., start-up, testing) but continuous operation must be restricted to the designated adjustable range. Excessive cycling at maximum pressure or temperature limits could reduce sensor life.
• A back-up unit is necessary for applications where damage to a primary unit could endanger life, limb or property. A high or low industrial limit switch is necessary for applications where a dangerous runaway condition could result.
• The adjustable range must be selected so that incorrect, inadvertent or malicious setting at any range point cannot result in an unsafe system condition.
• Install unit where shock, vibration and ambient temperature fluctuations will not damage unit or affect operation. Orient unit so that moisture does not enter the enclosure via the electrical connection. When appropriate, this entry point should be sealed to prevent moisture entry.
• Unit must not be altered or modified after shipment. Consult UE if modification is necessary.
• Monitor operation to observe warning signs of possible damage to unit, such as drift in set point or faulty display. Check unit immediately.
• Preventative maintenance and periodic testing is necessary for critical applications where damage could endanger property or personnel.
• For all applications, a factory set unit should be tested before use.
• Electrical ratings stated in literature and on nameplate must not be exceeded. Overload on a switch can cause damage, even on the first cycle. Wire unit according to local and national electrical codes, using wire size recommended in installation sheet.
• Do not mount unit in ambient temp. exceeding published limits.
LIMITED WARRANTY
Seller warrants that the product hereby purchased is, upon delivery, free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or material will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); provided, however, that this warranty applies only to equipment found to be so defective within a period of 24 months from the date of manufacture by the Seller (36 months for the Spectra 12, TX200 and One Series products; 18 months for Industrial temperature sensors and 12 months for Transducers). Seller shall not be obligated under this warranty for alleged defects which examination discloses are due to tampering, misuse, neglect, improper storage, and in any case where products are disassembled by anyone other than authorized Seller's representatives. EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
LIMITATION OF SELLER'S LIABILITY
Seller's liability to Buyer for any loss or claim, including liability incurred in connection with (i) breach of any warranty whatsoever, expressed or implied, (ii) a breach of contract, (iii) a negligent act or acts (or negligent failure to act) committed by Seller, or (iv) an act for which strict liability will be inputted to seller, is limited to the "limited warranty" of repair and/or replacement as so stated in our warranty of product. In no event shall the Seller be liable for any special, indirect, consequential or other damages of a like general nature, including, without limitation, loss of profits or production, or loss or expenses of any nature incurred by the buyer or any third party.
UE specifications subject to change without notice.
UN IT ED ELECTRIC CONTROLS
180 Dexter Ave, P.O. Box 9143 Watertown, MA 02471-9143 USA Phone: 617 926-1000
Fax: 617 926-2568 http://www.ueonline.com
SP070510M
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20