Unfors Xi Platinum Edition
Specifications
Unfors Xi General
EMC tested
Exposure needed
Reset
Temp. range
According to EN 61000-EN 61000-6-3:2001 One
Automatic
15 - 35 °C (59 - 95 °F)
Dose (R/F high)
Range
Uncertainty
10 uGy - 9999 Gy (1 mR - 9999 R) 100 uGy/s (0.7 R/min) 5 %
(40 - 150 kVp, HVL: 1.5 - 14 mm Al(l), Active Compensation) or ± 10 uGy (1 mR)
10 nGy/s -1 mGy/s (70 uR/min - 7 R/min)
l00 nGy/s (0.7 mR/min)
5 %
(40 - 150 kVp, HVL: 1.5 - 14 mm Al(l), Active Compensation) or ± l0 nGy/s (70 uR/min)
20 uGy/s - 1000 mGy/s(2) (140 mR/min - 7000 R/min) 100 uGy/s (0.7 R/min)
5 %
(40 - 150 kVp, HVL: 1.5 - 14 mm Al(l), Active Compensation) or ± l0 uGy/s (70 mR/min)
35 - 160 kV/kVp
2 %
(for total filtrations from 2.5 mm Al up to
1 mm Cu or equivalent, Active Compensation)
0.4 mA, 40 kV, 40 cm (15.7 in),
no added filtration
0.8 mA, 70 kV, 50 cm (19.7 in),
no added filtration
Dose rate (R/F low)
Min. peak trig level Uncertainty
Detector cable length 2 and 10 m (6.5 and 33 ft)
Software
Unfors Xi View for recording measured data and waveforms. Unfors Xi View also exports data to Microsoft Excel. RS-232 or Bluetooth XML
Germany DE69430268.6-08 UK 0758522 Japan 3449721 Sweden 9302909-8
France 075822 USA 5761270
Data transfer Data format Patent
Dose rate (R/F high) Range
Min. peak trig level Uncertainty
PTB Approva
Unfors Xi Base Unit
Size 28 x 74 x 142 mm (1.1 x 2.9 x 5.6 in)
Weight 250 g (9 oz)
Power off Automatic after 5, 20 or 60 min of inactivity
Power source Rechargeable NiMH standard 9 V
Battery time 10 - 20 hours (depending on detector and if
Bluetooth is used) Read out Three row alphanumerical backlit display
with four digits numerical resolution
kV/kVp Range
Uncertainty
Sensitivity (R/F low) Sensitivity (R/F high)
Unfors Xi R/F Detector
Exposure time Range
Uncertainty
1 ms - 999 s
0.5 % or 0.2 ms
1 - 9999 pulses > 3 uGy/s
Size Weight Jose (R/F low) Range Trig level Uncertainty
12 x 22 x 117 mm (0.5 x 0.9 x 4.6 in) 50 g (2 oz)
10 nGy - 9999 Gy (1 uR - 9999 R) 100 nGy/s (0.7 mR/min) 5 %
(40 - 150 kVp, HVL: 1.5 - 14 mm Al(l), Active Compensation) or ± 10 nGy (1 uR)
ulse
Peak trig level (R/F low) Peak trig level
(R/F high)
Unfors uncertainty definition
The expanded uncertainty is stated as the combined uncertainty of (l) 45 mm Al added filtration at 145 kVp gives a HVL of ~I3 mm Al.
measurement multiplied by the coverage factor k=2, which assuming a (2) 1000 mGy/s up to 70 kVp, 400 mGy/s at 100 kVp, 250 mGy/s at 140 kVp.
normal distribution has a coverage probability of 95 % (complies with GUM by ISO (1995, ISBN 92-67-10188-9)).