You may also be interested in
Digital light meter, Luminance meter, Measuring device, Detector, Dosimeter
Text version of the page
Unfors Xi Platinum Plus Spécifications Unfors Xi General EMC tested Exposure needed Reset Temp. range Detector cable length Software According to EN 61000-6-1:2001 and EN 61000-6-3:2001 One Automatic 15 - 35 °C (59 - 95 °F) 2 and 10 m (6.5 and 33 ft) Unfors Xi View for recording measured data and waveforms. Unfors Xi View also exports data to Microsoft Excel. RS-232 or Bluetooth XML Germany DE69430268.6-08 U K 0758522 Japan 3449721 Sweden 9302909-8 France 075822 USA 5761270 M5I Range Min. peak trig level Uncertainty 10 nGy/s -1 mGy/s (70 jR/min - 7 R/min) 100 nGy/s (0.7 mR/min) 5 % (40 - 150 kVp, HVL: 1.5 - 14 mm Al(l), Active Compensation) or ± 10 nGy/s (70 jR/min) 20 jGy/s - 1000 mGy/s(2) (140 mR/min - 7000 R/min) 100 jGy/s (0.7 R/min) 5 % (40 - 150 kVp, HVL: 1.5 - 14 mm Al(l), Active Compensation) or ± 10 jGy/s (70 mR/min) 35 - 160 kV/kVp 2 % (for total filtrations from 2.5 mm Al up to 1 mm Cu or equivalent, Active Compensation) 0.4 mA, 40 kV, 40 cm (15.7 in), no added filtration 0.8 mA, 70 kV, 50 cm (19.7 in), no added filtration 1 ms - 999 s 0.5 % or 0.2 ms Dose rate (R/F high) Range Min. peak trig level Uncertainty Data transfer Data format Patent kV/kVp Range Uncertainty PTB Approval Sensitivity (R/F low) Sensitivity (R/F high) Exposure time Range Uncertainty ; Xi Base Unit 28 x 74 x 142 mm (1.1 x 2.9 x 5.6 in) 250 g (9 oz) Automatic after 5, 20 or 60 min of inactivity Rechargeable 7.2 V Li-ion battery 20 - 40 hours (depending on detector and if Bluetooth is used) Three row alphanumerical backlit display with four digits numerical resolution Size Weight Power off Power source Battery time Read out Range Peak trig level (R/F 1 - 9999 pulses > 3 jGy/s Size Weight Range Trig level Uncertainty Range Trig level Uncertainty 12 x 22 x 117 mm (0.5 x 0.9 x 4.6 in) 50 g (2 oz) 10 nGy - 9999 Gy (1 |jR - 9999 R) 100 nGy/s (0.7 mR/min) 5 % (40 - 150 kVp, HVL: 1.5 - 14 mm Al(l), Active Compensation) or ± 10 nGy (1 jR) 10 jGy - 9999 Gy (1 mR - 9999 R) 100 jGy/s (0.7 R/min) 5 % (40 - 150 kVp, HVL: 1.5 - 14 mm Al(l), Active Compensation) or ± 10 jGy (1 mR) low) Peak trig level (R/F > 1 mGy/s high) Frame rate Range 1/6 - 120 frames/s Dose per frame Range l .0 nGy - 9999 Gy (0.l0 jR - 9999 R) per frame l.0 - l4.0 mm Al l0 % or ± 0.2 mm Al (at signal levels above l /1000 of max dose rate for selected sensor) 0.l kHz 2.5 kHz l 200 ms Range Uncertainty Bandwidth (R/F low) Bandwidth (R/F high) Memory depth (1) 45 mm Al added filtration at 145 kVp gives a HVL of ~l3 mm Al. (2) l000 mGy/s up to 70 kVp, 400 mGy/s at l00 kVp, 250 mGy/s at l40 kVp.
|
|