Accessories- cell disrupter 1000L - ULTRASONIC POWER Corporation - #1

/ 2


catalogue search
Accessories- cell disrupter 1000L - ULTRASONIC POWER Corporation
P. 01
Accessories- cell disrupter 1000L - ULTRASONIC POWER Corporation
P. 02
Pages:
Accessories- cell disrupter 1000L - ULTRASONIC POWER Corporation


See other catalogues for ULTRASONIC POWER Corporation

Text version of the page
Ultrasonic Power Corp. 239 E. Stephenson St. Freeport,Illinois, 61032, US Phone: 815-235-6020 Fax: 815-232-2150 Toll-free: 800-575-0168 Email: sonic@upcorp.com Website: http://www.upcorp.com Accessories- cell disrupter 1000L Accessories for all of your specific needs: Probes 5T Standard Probe 19mm the unit is supplied with the standard titanium probe. 108 mm long (4 19/64”), 19 mm (3/4"). 40TL Needle Probe 4mm resembles the standard probe, 127 mm long, 4 mm, (5/32"), titanium. With this probe very small volumes can be treated at extremely high energy levels. 50T Cantenoidal Probe 19mm due to its shape, this probe produces a wider area of cavitation than the standard probe. This is useful for dispersing and emulsifying. 30T Cup Probe 50 ML this probe consists of a solid titanium cylinder with a 50 ml cylindrical cavity machined into the end. The specimen is placed directly into this cavity or 1˝ ml micro centrifuge tubes are put in the water with the wetting agent in the cup tip for cell disruption. The cup tip can also be used for aerosol production and studying low level ultrasound effects on microorganisms. Cooling Jackets The use of a cooling jacket is recommended whenever the unit is operated either continuously or intermittingly for prolonged periods of time or when heat build up in the fluid must be avoided. The cooling jacket is slipped over the probe and a coolant flowing through the jacket cools the probe and the transducer. Cooling Jackets work by moving cool liquid past the transducer to remove unwanted heat from the probe and thus not transferring the heat into the sample. 7T Small Cooling Jacket for use with 5T standard probe when temperature control of the sample is a priority. 10T Large Cooling Jacket for use with the 50 ml cup probe when temperature control of the sample is a priority. Spanner wrench set for changing various horns. All Cell Disrupter packages carry a full 2 year warranty. Proudly made in the USA. Results 1 - 8 of 8 Item # Item Name Probe Length Probe Diameter List Price 51-03-016 5T Standard Probe 19 mm 108 mm 3/4 in. 19 mm $365.00 51-04-021 40T Needle Probe 4 mm 127 mm 5/32 in. 4 mm $325.00 51-04-020 12T Intermediate Probe 9.5 mm 123 mm 3/8 in. 9.5 mm $325.00 51-03-020 50T Cantenoidal Probe 19 mm N/A 3/4 in. 19 mm $610.00 12/2/2009 | Page 1 of 2

pageCatalog pdf di En 2012-02-06-10