OPERATING PRINCIPLE
To measure the flow of fr e e - s u r face, open
channels, rivers… a combination of velocity and
level measurements are re q u i red. The UF 322
range uses transit-time ultrasonic principle to
m e a s u re velocity.
The UF 322 co-s and UF 322 co m e a s u re the
flowrate by integrating the hydraulic profile fro m
2 to 6 velocity chords :
PERFORMANCE
m Accuracy on velocity measurement < +/- 0.5 %
m Accuracy on level acquisition < 0.1 %
(excluding errors of level device)
m Accuracy of section description < 0.25 %
m Typical accuracy of flow calculation :
1 to 5 % according to application and number of
chords
m Maximum length of channel : according to the
f requency of probes (0.5 MHz and more )
m Calculation of flowrate by programmable rule :
Flow = f (Level) when all probes are out of flow
FEATURES
m Graphical display of readings and curv e s
m Easy to use keypad steps through set up windows
m Diagnostic screen shows : Echo display, gain …
m Language choice : English, French, German,
Spanish, Italian…
m 8 site set-ups can be stored in memory
m Software for PC / Windows NT, 95, 98
m Date, time data logger
. 8 064 lines of 4 variables (32 400 in option) or
. 4 032 lines of 9 variables (16 200 in option)
m Direct transfer of data to spreadsheet
m Display : flow, velocity, level, volume …
m Isolated programmable current output 4-20 mA
m 3 programmable relays outputs : alarms, faults
totalisation…
m Numerical output RS 232 or 485 - JBus/Modbus
m Odd shaped channels can configured in set-up
(in 20 trapezial sections)
m Hydraulic model describes in 20 sections :
- fixed model : absolute mode
- variable model : relative mode
m Possible acquisition of 2 levels - alarm if different
m Ultrasonic signal processing with DSP (Digital
Signal Processing)
ELECTRICAL CHARACTERISTICS
m Power supply (max. consumption : 10 W) :
. 230/115 V AC 50/60 Hz
. 12 - 32 V DC as standard (option : 50 V)
m Inputs : 2 signals 4-20 mA for level(s)
15 V power supply for piezzo or ultrasonic sensors
2 wires
m Outputs
- 1 output 4-20 mA isolated – resolution 10-4
- 3 static relays outputs 100 V - 100 mA - 10 VA
- 1 output RS 232 or 485, 300 to 9600 Bauds,
JBus/ModBus.
MECHANICAL CHARACTERISTICS
m UF 322 e n c l o s u re is cast aluminium - epoxy coated ;
all cable entries are via plug type connections
m Protection IP 67 ; Relative humidity : 90 %
Temperature : - 25° C / + 50° C
m Dimensions : version CO-S : 340 x 240 x 123 mm
(H x L x D) version CO : 340 x 240 x 225 mm
m Submergeable probes.
NOTES ON SITE SELECTION
m P e rf o rmance and results mainly depend on geometric
readings, positioning and number of probes.
m Use of Ultraflux probe mounting tools is
recommended
m Avoid sites with bubbles or entrained air
Velocity 3 (V3)
Velocity 2 (V2)
Velocity 1 (V1)
Level
Flow
Example of results (3 chords)
t
Supply
Outputs
RS
UF322 co
Level 2 (and/or)
Level 1
Junction cable
Probes
|
|