Text version of the page
FILTERS
TANK CARE
Return Filters
RG
MATERIALS
Diffusor:
Zinc plated steel
Element support: Polyammide
(aluminium alloy for FRG3+ & 4+) Magnetic core:
Syntherized magnetic material
Seals: NBR Nitrile
(FKM - on request fl uoroelastomer)
MAGNETIC CORE The magnetic core (standard feature) ensures a magnetic pre-fi Itration of ferrous particles, even during bypass conditions.
DIFFUSOR
The diffusor (available as an option) smooths the oil fi ow thus reducing turbolen-ce inside the tank even in case of large f ow rates.
BYPASS
The bypass function is obtained by the f lter element moving axially, in such a way that the contaminant is retained in the f lter element during bypass conditions.
CUSTOMIZED MOUNTING The RG series f lter inserts have been designed to be mounted in custom-made housings inside the reservoir, providing low cost f ltration solutions and solving specif c assembly requirements.
INSIDE TO OUTSIDE
FILTRATION
"Inside-to-outside" f ltration ensures the contaminant is retained inside the element during replacement; also f l-ling or top-up of the reservoir can be done through the f lter thus avoiding the ingression of new contaminant.
PRESSURE (ISO 10771-1:2002)
Collapse, differential
for the fi Iter element (ISO 2941): 1 MPa (10 bar)
BYPASS VALVE
Setting:
option "E" 80 kPa (0,8 bar)+/- 10% option "F" 150 kPa (1,5 bar)+/- 10%
WORKING TEMPERATURE
From -25° to +110° C
COMPATIBILITY (ISO 2943:1999)
Full with fl uids: HH-HL-HM-HR-HV-HG (according to ISO 6743/4) For fl uids different than the above mentioned, please contact our Sales Department.