PFA lined Ball Valves - Type NTB- and NTC
ISO 5211 - flange and stem adapter dimensions
With bare shaft (Code B) Notes
Size mm Double "D" Diag. Sq. Stem Dia. K G H h/h^ Lt B 1) All mounting flanges for a valve size
15 - 20 7 - 11 M5 22 2 15 8 18 DN 150 have a recess (hi).
25 - 40 10 - 12.8 M6 22 3 15 9 19 2) The mounting flange is an integral part of
50 10 - 14 M6 22 3 15 9 19 the valve.
65 - 80 - 14 18 - 33.5 3 25 - 19
100 - 16 20 - 33.5 3 25 - 19
150 - 22 28 M8 32 131) 35 20 30
stem adapter
stem adapter
mounting ring
mounting flange
mounting flange
applies to flange sizes marked 4) only
to C of valve
applies to all other (oversize) flanges only
to (J. of valve
With mounting flange for actuators built to ISO 5211/DIN 3337 (Code 1 - 7)
Size mm
ISO Flange
A
B
C
d1
d2
d3
d4
s3)
15 - 20
F044)
95
30
11.5
54
30
42
5.4
11 x 11
15 - 20
F05
93
27.5
12.5
65
35
50
7
14 x 14
15 - 20
F07
93
27.5
15.5
90
55
70
9
17 x 17
25
F054)
115
27.5
15.5
65
35
50
7
14 x 14
25
F07
115
27.5
18.5
90
55
70
9
17 x 17
25
F10
115
27.5
22.5
125
70
102
11
22 x 22
40
F054)
128
27.5
15.5
65
35
50
7
14 x 14
40
F07
128
27.5
18.5
90
55
70
9
17 x 17
40
F10
128
27.5
22.5
125
70
102
11
22 x 22
50
F074)
133
27.5
18.5
90
55
70
9
17 x 17
50
F10
133
27.5
22.5
125
70
102
11
22 x 22
50
F12
132
26.5
27.5
150
85
125
13
27 x 27
65 - 80
F074)
171
31
18.5
90
55
70
9
17 x 17
65 - 80
F10
168
27.5
22
125
70
102
11
22 x 22
65 - 80
F12
165
24.5
25
150
85
125
13
27 x 27
65 - 80
F14
165
24.5
30
175
100
140
17
36 x 36
100
F074)
187
31
18.5
90
55
70
9
17 x 17
100
F10
184
27.5
22
125
70
102
11
22 x 22
100
F12
181
24.5
25
150
85
125
13
27 x 27
100
F14
181
24.5
30
175
100
140
17
36 x 36
150
F10
246.5
30.5
23.5
125
70
102
11
22 x 22
150
F12
243
27
27
150
85
125
13
27 x 27
150
F14
238
22
32
175
100
140
17
36 x 36
150
F16
238
22
40
210
130
165
22
46 x 46
Notes
• Flange and stem dimensions are In millimeters.
3) Diagonal square to ISO 5211.
4) Flange dimensions for standard ball valves.
• Removal, alteration or modification will disturb "live-loaded" stem seal design and void warranty. Consult your Neotecha technical representative.
Tyco reserves the right to change the contents without notice page 8

pageCatalog pdf di En 2012-06-22-01