Absolute Electro-optical Encoders KBE 10828 FE01 / 2005 KBE 58-S and KBE 58-K SINGLE TURN Interfaces serial SSI or parallel

LOW-COST, compact and robust formechanical engineering and instrumentation Output codes:Gray or Natural Binary Resolution:8192 positions/360°<) - 13 BitsOptional: Serial SSI : 14, 15, 16 Bits Parallel: 14 Bits Model KBE 58-SModelKBE 58-K Model "S" withsynchro flangeModel "K" withclamping flange Protection grades:IP 64 (KBE 58-S)IP 66 (KBE 58-K) Option with SSI :Zero reset via push buttonand via functional input

Construction

Supply current Flange and housing in aluminium - shaft in stainless steel ,ball-bearings with sealing - code disc in plastic or glass -GaAlAs-diodes - photo-transistor array with comparator andtrigger circuits - gate array - SMD technology. serial SSI :40 mA typ. / 50 mA max. parallel:40 mA typ. / 60 mA max. EMC:EN 50081-2, EN 50082-2

Mechanical dat a Electrical data

Operating speed:10.000 min
-1 max. Sensor system:GaAlAs-diodes,photo-transistor array Angular acceleration:10
5 rad/s² max. Inertial mass of rotor:15 gcm² Resolution (standard):8192 positions / 360°<) -13 Bit Operating torque: ≤ 3 Ncm (KBE 58-S) Resolutions (optional): SSI : 14, 15, 16 BitParallel: 14 Bit ≤ 8 Ncm (KBE 58-K) Wind-up torque: ≤ 1 Ncm (KBE 58-S) Disc-coding:Gray ≤ 4 Ncm (KBE 58-K) Output code:Gray or natural binary Permissible shaft load
3) :100 N axial100 N radial Code sense:CW or CCW (Input E6/E7 ≤ ± 1' 59" at 13 Bits (± 1 digit)
4) ) Measuring position deviation: Bearing life expactancy
3) :10
9 turns Mass:0,25 kg approx. Output serial SSI :Differential (RS 422/485) Clock input SSI :Differential-via optocoupler(RS 422/485)

Environmental data

Operating temperaturerange:- 20° C to + 60° C Zero resetting (optional SSI ):Input E6
2) at option:- 40° C to + 85° C Storage temperature range:- 40° C to + 85° C Output parallel:F = HCMOS Permissible rel. humidity:85 % without condensation
(at option)(Supply voltage: 5 VDC, length ofoutput lead 300 mm, not tobe increased) Resistance to shock:200 m/s² ; 11 ms(DIN EN 60068-2-27) Resistance to vibration:5 Hz ... 1000 Hz ; 100 m/s²(DIN EN 60068-2-6) D = push-pull
(Supply voltage: 30 VDC) Protection grade (DIN EN 60529)KBE 58-S:IP 64KBE 58-K:IP 66 (with sealing ring) Latch
1) :Input E6 (Latch) Enable - circuit
1) :Activ or inactiv,Input E6 (for bus mode) Output frequency
1) : ≤ 10 kHz
1) Supply voltage range "
For parallel interfaces only. 2) SSI " and "D":+ 11 VDC bis + 30 VDC
Instead of zero reset any preset value can be implementedbefore delivery (to be specified). Supply voltage range "F":+ 5 VDC ± 0,25 VDC
3) At reduced shaft load the other values can become increased. 4) F-Output: E7