Hygienic Valves VARIVENT and ECOVENT Catalog 2014
290Pages

{{requestButtons}}

Catalog excerpts

Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 1

GEA Tuchenhagen Hygienic Valves VARIVENT ® and ECOVENT ® Business Line Hygienic Valve Technology Catalog 2014 engineering for a better world

Open the catalog to page 1
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 3

Legal notice Publication date: November 1, 2014 The publication of specifications, technical data and information in written or electronic form does not release the user from the responsibility of checking for themselves all products delivered by us for suitability for the application(s) intended. These may be subject to change without prior notification. Errors and printing errors excepted – we assume no liability for the correctness of ­ specifications given. The general terms and conditions of delivery apply. All rights reserved – copyright on all contents GEA Tuchenhagen GmbH Am...

Open the catalog to page 3
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 6

GEA Tuchenhagen Business Unit GEA Flow Components Whether it's dairy, beer, viscous food ingredients or fine-chemical products – product quality and profitability are what matter in the end. This is precisely what the business unit GEA Flow Components stands for – it's a specialist with many years of experience for everything that flows. The GEA Group The GEA Group, with operations worldwide, is divided into business areas. One of these is GEA Mechanical Equipment, which consists of the four business units: GEA Flow Components, GEA Homogenizers, GEA Food and GEA Mechanical Separation. The...

Open the catalog to page 6
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 7

GEA Tuchenhagen Business Unit GEA Flow Components Four business lines – for everything that flows The product range of the business unit GEA Flow Components includes hygienic and aseptic valve technology, hygienic pumps and cleaning technology. These products are used particularly for the brewing, beverages, dairy and food industries, as well as for the pharmaceutical, health care, biotechnology and fine-chemicals industries. Hygienic valves and components from GEA Tuchenhagen form the core component of matrix-piped process plants. For aseptic processes, which require components with the...

Open the catalog to page 7
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 8

Hygienic Valves Introduction to Hygienic Valves GEA Tuchenhagen products are based on future-oriented company and product design principles that include an obligation to economic viability, sustainability and service. Your investment pays off GEA Tuchenhagen VARIVENT® and ECOVENT® hygienic valves help you to achieve considerable cost savings. The valve concepts with a variable structure and the efficient control technology provide both low purchase costs and low energy consumption. The design of the valves and individual components without dead space satisfies the most exacting hygienic...

Open the catalog to page 8
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 9

Hygienic Valves Introduction to Hygienic Valves You score points with environmental protection Our support is your gain Lower consumption of energy, water and chemicals means less pollution for the climate and environment. GEA Tuchenhagen meets these requirements by complying with binding international standards. In addition to our product range, you can also make use of the individualized engineering support from GEA Tuchenhagen. Even before you have started using our products, this support provides you with extensive digital tools – from technical drawings through to 3-D models. As a user...

Open the catalog to page 9
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 10

Hygienic Valves Overview Hygienic valves Sealing according to the VARIVENT® principle VARIVENT® and ECOVENT® hygienic valves offer reliable function, are suitable for CIP / SIP, easy to maintain and represent a significant factor in consistent product quality. Low operating, maintenance and servicing costs ensure economical system productivity. The hygienic valves are characterized by special seal technology. A metallic stop results in defined seal deformation, ensuring long seal life. This allows for more time to pass between required maintenance services with the process system, thereby...

Open the catalog to page 10
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 11

Hygienic Valves Overview The VARIVENT® modular system 1 Control and feedback system The high flexibility in the VARIVENT® system offers many advantages. With the ability to combine all basic elements with one another, the system offers a broad range of possible applications. Existing valve systems in process installations can be modified or adapted without changing the current system concept. Both variants of the T.VIS® generation offer the opportunity of selecting between two feedback systems variably depending on the customer requirements. Whether the proven sensor technology in the...

Open the catalog to page 11
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 12

Hygienic Valves Technical Data Available nominal widths for valve series Section Shut-off valve type N Shut-off valve type N small Divert valve type W Divert valve type W small Bottom valve type N Shut-off valve type N Long-stroke shut-off valve type N_V Shut-off valve type U Long-stroke shut-off valve type U_V Divert valve type W Divert valve radial sealing type W_R Long-stroke divert valve type W_V Divert valve type X Long-stroke divert valve type X_V* Double-seat valve type D Double-seat valve type B Double-seat valve type R Double-seat long-stroke valve type D_/ V* Double-seat valve...

Open the catalog to page 12
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 13

Hygienic Valves Technical Data Materials Housing connections Components in contact with the product are produced from 1.4404 / AISI 316 L, while those not in contact with the product use 1.4301 / AISI 304. Other materials, e.g. for use when handling aggressive fluids, are available on request. Two alternative housing connections are available: the clamped connection (standard) and the fixed housing connection. The clamped housing selection permits a flexible choice of port orientation. For detailed information about the properties of the materials, refer to the material properties table...

Open the catalog to page 13
Hygienic Valves VARIVENT and ECOVENT  Catalog 2014 - 14

Hygienic Valves Technical Data Ambient conditions Operating pressure Ambient temperatures VARIVENT® / ECOVENT® (with T.VIS® control module) Proximity switches The valves can also be used outdoors. However, in these application areas they must be protected against icing, or else deiced before switching or lifting. In addition, the particular requirements on the control and feedback system must be taken into account in this case. The product or operating temperature depends on the seal material and can be seen in the seal material properties table (see page 15). Installation VARIVENT® and...

Open the catalog to page 14

All GEA Tuchenhagen catalogs and technical brochures

  1. VARIVENT®

    32 Pages

  2. STERICOM®

    12 Pages

  3. ECOVENT®

    6 Pages

  4. VARIVENT®

    28 Pages

  5. Catalog 2013

    74 Pages

Archived catalogs