NORMA CEIEN 50086

( in force since January 1st 1996) classificazione classificazione secondole vecchie norme CEI EN50086 The general standard EN50086.1 is divided in four subnorms which prescri-be specifical tests to be effected on each product: EN 50086-2-1for rigid conduitEN 50086-2-2for pliable conduit (corrugated) EN50086-2-3for flexible conduit (sheaths) EN 50086-2-4for underground pipes
prodotto TF1
(PVC corrugated - black and coloured 3 - 3 - 2 -1 P=heavy
(750 Newton) RF15
(PVC rigid - gray) 3 - 3 - 2 -1 P=heavy
(750 Newton) RF20
(PVC rigid - gray) 4 - 3 - 2 -1 not appliable ICTA
(PP corrugated - gray) 3 - 4 - 2 -2 ICT 390 TCT
(PP corrugated - orange) 2 - 2 - 2 - 2 TCT 90L TFG
(spiral sheaths) 2 - 3 - 1 -1 not appliable CAF
(underground pipes) 3 - 3 - 2 -2 not appliable

UNDERGROUND AND PLASTIC FITTINGSSYSTEMS FLEXIBLE PLIABLE AND PLAIN SELF-RECOVERING CONDUITS AND FITTING SYSTEMS

FIELD OF APPLICATION FIELD OF APPLICATION
Underground conduit systems and metallic and non-metallic conduit fittings, assem-bled, threaded and non. Conduit systems and fittingsConduit systems and pliable metallic fittings and non, assembled, threaded and non MARKINGS CLASSIFICATIONS
Heavy-duty conduit: Trade mark; Product identification mark; L (light); N (normal) Markings: between 1 and 3m Fittings: Trade mark; Product identification mark; L; N Composed of 12 figures MARKINGS AND DOCUMENTATION
Conduit: Trade mark; Product identification Conduit may be also marked with classification code of at least 4 figures. Conduit markings: Spacing pref. at intervals of 1m but not greater than 3m; each spacing marked at least once Fittings: Code of at least 4 figs; or labelling on product or packaging Manufacturer must specify min. inner diameter of system DIMENSIONS
Table 101 only conduits (lowest min. ø) Sizes: 25; 32; 40; 50; 63; 75; 90; 110; 125; 140; 160; 180; 200; 225; 250mm MECHANICAL PROPERTIES
Bending test: 3 tests: room temp. -3 tests: -5°C Pulley radius: 15 x outer ø Conduit should not flatten; Verify by gauge 95% min inner ø Impact resistance: Speed 15mm/min.; value force which causes flattening 5% inner diameter prev. calculated. When flattening reaches 5%, applied force should be at least 450N L: 200mm Low temp. resistance test: Not applicable Light heavy-duty conduit: 3kg; Height H depends on diameter (100÷500mm) Normal heavy-duty conduit: 5kg; Height H depends on diameter (300÷800mm) DIMENSIONS
Outer diameters: EN 60423 (as per standards) Inner diameter: min. diameter of system as specified by manufacturer SIZES
(in mm)6; 8; 10; 12; 16; 20; 25; 32; 40; 50; 63; 75mm. MECHANICAL PROPERTIES
Non-metallic bending test: all diameters Plain conduits: 30 x outer ø Corrugated conduits: 12 x outer ø bending test fig. 101 Verify using gauges 80% inner ø (Supplied by manufacturer) fig. 102 Compression test: Light 320N; Medium 750N; Heavy 1250N; Ex heavy 4000N Flattening: 25÷50% self-recovering Low temp. resistance test: Not applicable Light: 1kg H=100mm Medium: 2kg H=100mm Heavy: 2kg H=300mm Ex heavy: 6,8kg H=300mm Tensile test: Conduit + fittings Suspended load test: Fittings FLAME PROPAGATION RESISTANCE
Conduits: Lenght 675mm Bunsen burner as IEC 695-2-4 1KWSteel conduit in test Time of exposure to flame: depends on conduit thickness Fittings: Glow wire 750°C DIELECTRIC STRENGTH
Water temp.: 23 ±2°C Salt water (lg/l) Insulation: water temp.: 23 ±2°C Fittings: According to manufacturer’s instructions With the receipt of New Approach Directives, the products which apply within their fieldof application must be manufactured in conformity with the relevant and essential requi- rements that must be met to be put in the market and in service across the European Community.A presumption of conformity to European New Approach Directives is the affixing of theCE Marking on the product and/or on its instruction manual and/or on the packaging.The Directives that can be applied to TUBIFOR products are the following: Dir. 72/23/CEEreceipt with the Rule Nr. 791 dtd. 18/10/1977 and amended by the Dir. 93/68/CEE related to the relevant safety standards of electrical material included in the Low Voltage Directive.The CE Marking must be applied since01/01/1996 according to Dir. EMC (89/399/CEE and 93/68/CEE);01/01/1997 according to Dir. LVD (73/23/CEE and 93/68/CEE);TUBIFOR products which apply to Directives bear the CE Marking since the above indica-ted dates. FLAME PROPAGATION RESISTANCE
Conduits: length 675mm Bunsen burner as IEC 695-2-4 1 KW Time of exposure to flame: depends on conduit thickness Verification: tissue paper burning test plus other verifications Fittings: Glow wire 750°C HEAT RESISTANCE
Heat compression test: Temp. as per classification plus weight External influences: Verify protection grade IP

6

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
pdf-page pdf di En 2008-10-42-14