You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | |
| | | |
| | | Turcon® Roto Glyd Ring® | | |
| | | |
| | | ■ Installation recommendation - internal sealing | | |
| | | |
| | | Figure 91 Installation drawing | | |
| | | |
| | | Table LXII Installation dimensions | | |
| | | |
| | | | | | | | | | | | | | | | | | Series no. | Rod diameter dN f8/h9 | Groove diameter | Groove width | Radial clearance S max. * | Radius | O-Ring cross sec. | Number of grooves in the sealing surface | | | | Standard range | Available1' range | D, H9 | L, +0.2 | 10 MPa | 20 MPa | ri | d2 | | | | TG30 | 6- 18.9 | 6 - 130.0 | dN+ 4.9 | 2.20 | 0.15 | 0.10 | 0.40 | 1.78 | 0 | | | | TG31 | 19- 37.9 | 10 - 245.0 | dN+ 7.5 | 3.20 | 0.20 | 0.15 | 0.60 | 2.62 | 1 | | | | TG32 | 38 - 199.9 | 19 -455.0 | dN+ 11.0 | 4.20 | 0.25 | 0.20 | 1.00 | 3.53 | 1 | | | | TG33 | 200 - 255.9 | 38 - 655.0 | dN+ 15.5 | 6.30 | 0.30 | 0.25 | 1.30 | 5.33 | 2 | | | | TG34 | 256 - 649.9 | 120 - 655.0 | dN+ 21.0 | 8.10 | 0.30 | 0.25 | 1.80 | 7.00 | 2 | | | | TG35 | 650 - 999.9 | 650 - 999.9 | dN+ 28.0 | 9.50 | 0.45 | 0.30 | 2.50 | 8.40 | 2 | | | | | | | | | | | | | | | | | |
| | | |
| | | Provide split housing grooves according to diameter, see Table LVIII. At pressures > 10 MPa it is recommendable that for the cross section you choose the next larger profile according to the column "Available range" i.e. for shaft 080 mm: TG 33 00 800-. * At pressures > 30 MPa: Use diameter tolerance H8/f8 (bore / rod) in area of seal. | | |
| | | |
| | | MM | | |
| | | |
| | | Latest information available atwww.tss.trelleborg.com Edition April 2007 | | |
| | | TRELLEBORG SEALING SOLUTIONS | | |
| | | |
| | | 199 | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | |