See other catalogues for TM Robotics
You may also be interested in

Software, Vision system, Robot, SCARA robot, Cartesian robot


Text version of the page
High-performance master unit: (designed for CC-Link) CA10-M01B-CC
[Connection method of CC-Link cables and example connection of emergency stop input and output]
* For the table of I/O pin numbers, see Page 205.
[Connection method of CC-Link exclusive cables]
[1 ] Be sure to connect terminating resistors with units on both ends of the CC-Link system.
Connect each terminating resistor between DA and DB. [2] In the CC-Link system, terminating resistors to be connected differ with cables to be used.
Type of cable
Terminating resistor
CC-Link exclusive cable
110 Q, 1/2 W (brown, brown, brown)
CC-Link exclusive cable designed for Ver1.10
High-performance CC-Link exclusive cable
130 Q, 1/2 W (brown, orange, brown)
No terminating resistors are attached to this controller. [3] The connection method is shown below.
User's sequencer (i.e., PLC) DA
CA10-M01-CC
□A
Terminator
Terminati
DR —3T
CC-Link exclusive cables
SLD
SLD
FG
FG
Ï1
[Emergency stop output]
[Emergency stop input]
Connector pin number
Remote-controlled emergency stop switch Use a normal close (NC) switch.
+24V-
Output type: Relay contact output (OMRON-make, G6E-134P or equivalent)
4.7KQ
N.O
N.C
At emergency stop
Closed
Open
At normal operation (NORMAL)
Open
Closed
-a
Emergency stop output
Emergency stop input
Connector pin number
Controller side (master unit)
Controller side (master unit)
CC-Link connector (accessory)
Used to connect a CC-Link exclusive cable for data linkage.
Perform wiring to this connector, which should be inserted then to the CA10-M01B controller.
Emergency stop connector (accessory)
Used for input and output of emergency stop signal.
Perform wiring to this connector, which should be inserted then to the CA10-M01B controller.
CD CD
c/T o
3"
"O CD
O
CD
m
CD
3 ~o
CD
O
o
CD
o
Pin No.
Signal name
Cable color
Description
1
EMONC
Output
Emergency stop output (N.C)
2
EMOCOM
Output
Emergency stop output (COM)
3
EMONO
Output
Emergency stop output (N.O)
4
EMIN
Input
Emergency stop input
5
EMIN
Input
Emergency stop input
Connector pin array
Pin No.
Signal name
Cable color
Connector pin array
1
2
3
4
5
Communication cable (DA)
Blue
1
2
Communication cable (DB)
White
3
Digital GND (DG)
Yellow
5
Connector made by Wago Japan Type: 734-105
4
Shield (SLD)
Shield
Connector made
by Phoenix Contact
Type: MSTB2.5/S-ST-5.08AU
5
Frame ground (FG)
SLD and FG are connected in the unit.
238