You may also be interested in
Flow-meter, Sight glass, Vortex flow-meter, Air operated valve, Sensor
Text version of the page
1 bar = 0.1 MPa
Meter Body / Sensor
Transmitter Terminals
Pressure/Temperature Operating Range
Temperature (°C)
Pressure (barg)
Display
Transmitter
Re=———
Reynolds Number (Re) Calculation:
í
d = pipe diameter V = velocity
í = viscosity
d x V
1) Subject to the limitations of fluid freezing point 2) For superheated steam, air and other gasses, an
external pressure sensor and flow computer may be required if inlet pressure fluctuates
3) Do not use for toxic, flammable or otherwise hazardous fluids 4) + 0.3% for remote version
1 2 3 4
+ - + -
Esc
- + E
48.25 kg/h
I 3702.6 t
Connection
Size
Connection Compatibilities
Operating Pressure Range (barg)
Temperature Range (°C)
Applicable Fluid
Accuracy
Repeatability
Vibration Resistance
Volume Flow
Mass Flow
0 – 49.6 (See the table to the right for details)
-2001) – +400 (See the table to the right for details)
Steam2), Air 2), Water and others2) 3)
Gas/Steam:± 1% of reading (Re > 20 000),
± 1% of full scale (Re: 4 000 – 20 000)
Liquid: ± 0.75% of reading (Re > 20 000)
± 0.75% of full scale (Re: 4 000 – 20 000)
Saturated ± 2% of reading4) (Re > 20 000)
Steam: ± 2% of full scale4) (Re: 4 000 – 20 000)
Within 0.25% of reading
At least 1G in all directions (10 – 500 Hz)
Flangeless Flanged
DN 15, 25, 40, 50,
80, 100, 150
DN 15, 25, 40, 50, 80,
100, 150, 200, 250, 300
See details in the Dimensions section
Model EF73
Mounting Position No restriction with regards to meter accuracy
Explosion Class
Ambient Temperature
Ingress Resistance
Output
Power Source
Power Consumption
Power Line Connection
Field Wiring
Load Line Resistance
Non-explosion proof
Compact Type: -40 – +70 °C
Remote Type: -40 – +80 °C
IP 67 (NEMA 4X)
Frequency (pulse) output: Open collector pulse (passive)
Analog output: 4 – 20 mA DC
12 – 36 V DC (24 V DC recommended)
1.2 W DC (including sensor)
G(PF)a/B
2-wire System (2-conductor, shielded, at least 1.25 mm2)
Maximum 550Ů at 24 V
A B
C
To avoid abnormal operation, accidents or serious injury, DO NOT use
this product outside of the specification range. Local regulations may
restrict the use of this product to below the conditions quoted.
CAUTION
Sample
display
A: Power supply/
current output
B: Optional frequency
output
C: Ground terminal
(for remote version)
Specifications
-200 -100
0
5
10
15
20
16
25
30
0 100 200 300 400
35
40
45
50
49.6
55
DIN PN 10, JIS 10K
JIS 20K
ASME 150
DIN PN 16
DIN PN 25
DIN PN 40
ASME 300
Maximum Operating Pressure
High-performance vortex flowmeter with robust
sensor for highly accurate volume or mass flow
measurements of gasses, liquids, saturated and
superheated steam.
1. DSC (Differential Switched Capacitance) sensor
offers a wide measuring range, with a high
resistance to thermal shock, vibration and water
hammer.
2. Integrated flow computer calculates mass flow from
measured volume flow and temperature variables.
3. Capable of simultaneous pulse (interval) and
analog (instantaneous) output.
4. Requires no maintenance, has no moving parts,
and experiences no zero point drift.
5. Low pressure drop through body.
Features
SDS U1200-08
VORTEX
FLOWMETER
MODEL EF73 STAINLESS STEEL
RELIABLE FLOW MEASURING SYSTEM FOR GAS, STEAM AND LIQUIDS
|
|