Improved Performance - Less Maintenance
Easy Maintenance
All internal parts can be accessed by removing the trap cover.
Overexpansion Protection
The thermo-element is protected from overexpansion by the overexpansion spring, providing stable performance and long life.
Labor-Saving Design
Durable Construction
A unique nipple is incorporated into the trap inlet to facilitate installation and removal of the trap with wrenches and channel-locks.
No leakage through the trap orifice, due to the durability and smooth sealing of the ball valve.
Improved Valve Seat
A larger valve orifice permits more rapid purging of rust, scale and initial air, allowing faster warm-ups.
Radiator Trap
RI3A
Cold 185
water
F Hot water
5000
Body Material
Brass
Connection
Screwed
Size
V2", 3/4M
Max. Operating Pressure
PMO
45 psig
Min. Operating Pressure
1.5 psig
Max. Operating Temperature
TMO
292 °F
Max. Allowable Pressure
PMA
45 psig
Max. Allowable Temperature
TMA
292 F
Open-Close Temperature
approx. 203 °F - 212 °F
3000 2000
1000 700
500 300
it
'5 a
Ol
im
u
vi
ˇ5
200
0.1 0.3 0.5 1 2 3 5 10 2030 45
Differential Pressure (psi)
To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside the specification range. Local regulations may restrict this product below the conditions quoted.
CAUTION
Operation
0
At low temperatures during start-up, the thermo-element (A) is fully retracted, keeping the valve fully open and allowing air and condensate to be discharged.
After discharging the initial condensate from start-up, as the condensate temperature raises past approx. 212 °F the thermo-element (A) expands and pushes the valve shut.
When the temperature of the condensate in the trap drops below approx. 203 °F, the thermo-element (A) retracts, discharging condensate. If the temperature raises above approx. 212 °F, the valve shuts again as in step 2.
DO NOT DISASSEMBLE OR REMOVE THIS PRODUCT WHILE IT IS UNDER PRESSURE. Allow Internal pressure of this product to equal atmospheric pressure and Its surface to cool to room temperature before disassembling or removing. Failure to do so could cause burns or other injury. READ INSTRUCTION MANUAL CAREFULLY.
CAUTION
TLV CORPORATION
13901 South Lakes Drive, Charlotte, NC 28273-6790 Phone: 704-597-9070 Fax: 704-583-1610 Member of E-mail: tlv@tlvengineering.com M^cs
ISO 9001/ISO 14001
Manufacturer
T
f® co., ltd.
Kakogawa, Japan
is approved by LRQA Ltd. to ISO 9001/14001
FLUID CONTROLS INSTrTUTE
For Technical Service 1-800 '' TLV TRAP"
Internet World Wide Web URL http://www.tlv.com Pamphlet A2008-2 Rev. 1/2008
Specifications subject to change without notice.
(M)

pageCatalog pdf di En 2012-06-22-01