Star Lodge, Montpellier Drive, Cheltenham, Gloucestershire, GL50 1TY, U.K. Tel: [44]-(0)1242-227223 Fax: [44]-(0)1242-223077 Pamphlet U3000 Rev. 11/2007 Specifications subject to change without notice. (O) Ą Specifications Ą Typical Installation 6 barg Type 10 barg Type Screwed, Socket Welded, Flanged 1/2”, 3/4”, 1”, 11/2”, 2” / DN 15, 20, 25, 40, 50 6 10 165 185 0.5, 2, 5 Acid Cleaning (lost-wax cast) To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside the CAUTION specification range. Local regulations may restrict this product below the conditions quoted. Type Connection Size Maximum Operating Pressure (barg) PMO Maximum Operating Temperature (°C) TMO Filter Grade* (ėm) Internal & External Finishing** Ferrule Clamp Washing (hot/cold water, steam or air) Dirt & Scale Blowdown Piping Blowdown SF1 Valve Valve* Valve Valve Valve Steam Trap Union Dirt & Scale Collection Valve Pressure Gauge Pressure Gauge *Consult TLV for other available filter grades 1 bar = 0.1 MPa **Optional electro-polishing (lost-wax cast) available on request PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS): Maximum Allowable Pressure (barg) PMA: 6 (6 barg Type); 10 (10 barg Type) Maximum Allowable Temperature (°C) TMA: 165 (6 barg Type); 185 (10 barg Type) 6 barg Type (1/2” -11/2”/DN15 - 40): three-piece wing nut clamp; 6 barg Type (2”/DN50), 10 barg Type (all sizes): two-piece two-bolt clamp * or trap with sufficient discharge capacity when differential pressure is extremely low