Linear Transducers - Thermosystems - #1

/ 2


catalogue search
Linear Transducers - Thermosystems
P. 01
Linear Transducers - Thermosystems
P. 02
Pages:
Linear Transducers - Thermosystems


See other catalogues for Thermosystems

Text version of the page

TRASDUTTORE LINEARE DI POSIZIONE POSITION LINEAR TRANSDUCER

Linear Transducers - 24888 PL

C

AMPO DI MISURA DA

50 mm

FINO A

1.000 mm. E

LEVATA PRECISIONE

. E

LEVATA RISOLUZIONE

(0,01mm).

PL serie position linear transducers are potentiometers for industrial applications. Their characteristics like precision, linearity, compactness and stoutness are well suited for plastic, wood, marble, metal sheet machinery and every applications with absolute measurements of position or displacement. Mounting is very easy and they are interchangeable with other manufacturers’ models.

E

CCELLENTE RIPETIBILITA

’. V

ITA ESTREMAMENTE LUNGA

. B

ASSO COSTO

. M

EASUREMENT RANGE

50 mm

TO

1.000 mm. H

IGH ACCURACY

. H

IGH RESOLUTION

(0,01 mm). E

XCELLENT REPEATABILITY

. V

ERY LONG LIFE

. L

OW COST

.

CARATTERISTICHE PRINCIPALI GENERAL SPECIFICATIONS

I trasduttori lineari di posizione serie PL sono potenziometri per applicazioni industriali. Le loro caratteristiche di precisione, linearità, compattezza e robustezza li rendono particolarmente adatti ad impieghi in macchine per termoplastici, legno, marmo , lamiera ed in tutte le applicazioni di misure assolute di posizione o di spostamento. Il montaggio è estremamente semplice ed è possibile l’intercambiabilità con modelli di altri produttori.

CARATTERISTICHE TECNICHE TECHNICAL SPECIFICATIONS

Type designations PL 50 PL 100 PL 150 PL 200 PL 250 PL 300 PL 350 PL 400 PL 500 PL 600 PL 750 PL 900 PL 1000 Electrical Data Nominal electrical range ( NER ) 50 100150200250300350400500 600 7509001000mm Real electrical stroke ( RES ) 51 101151201251301351401501 601 7519011001mm Nominal resistance 5 55555555 5 101010K Resistance tolerance (20°C) 20 % Independent linearity 0,1 % Repeatability 0,01 % Maximum power rating (70°C) 0,2 0,40,60,81,01,21,41,62,0 2,4 3,03,64,0W Wiper current Recommended : 1 A - Maximum continuous : 1 mA Insulation resistance 10 M - 500 V
DC Dielectric strength 1000 V
RMS - 50 H
Z Mechanical Data Body length ( BL ) 125 175225275325375425475575 675 8259751075mm Mechanical stroke ( MS ) 56 106156206256306356406506 606 7569061006mm Body Anodized aluminium Shaft (free rotation) Stainless steel Operating force 7,5 N typical Electrical connections 4 pole socket DIN 43650 (hydraulic type ) Fixings By sliding brackets Total weight 220 280350400460520580650780 900 105011501300g Environmental Data Life 100 millions cycles typical Temperature range -50 +120 C Operating speed (max) 10 m/s Operating acceleration (max) 200 (20 g) m/s
2 Sine vibration (3 axes) 1,5mm peak to peak 0 10Hz / 15g 10 2.000Hz Mechanical shocks (3 axes) 50 g – 11 ms – half sine Protection class IP 50 NOTA: ogni potenziometro viene fornito completo di due staffe di fissaggio e di connettore quattro poli DIN 43650. NOTE: every linear transducer is supplied with two sliding brackets and one four-poles socket DIN 43650.

pageCatalog pdf di En 2012-06-22-01