|
|
See other catalogues for ThermoProbe
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | ThermoProbe mc | | | | | | | | | | SPECIFICATIONS | | | | | | | | | | | | | | | | | Maximum Dimensions: | 9.05x 7.20x 1.76 in. 23 x 18.3 x 4.5 cm. | | | | Total Weight- | 3 lbs with 75 ft of cable 1.4 kg with 23m of cable | | | | Approved Battery Type: | 9 volt Alkaline, Duracell MN1604 Rayovac A1604 Eveready 522 | | | | Battery Life: | Approximately 40 hours | | | | Case Materials: | Anodized Aluminum | | | | Limited Warranty: | 90 days on Probe Assembly 1 year on other components | | | | Probe: | Stainless Steel probe with static dissipating non-stick cable jacket, 0.020" thick Standard lengths 50715m 75723m 110734m | | | | Temperature Range: | -60 to 200 °F -55 to 150 °C | | | | Accuracy: | ±0.3 °F 32 to 200 °F ±0.2 °C, 0 to 100 °C | | | | Options: | Extra Weight Probe Asphalt Weight Probe Extra Length Sensor Railcar Sensor Custom | | | | | | | | | | | | | TP5 | | | | | | | | | | The TP-5 is a basic petrochemical gauging thermometer designed to be rugged, simple and compact yet remain lightweight. The case is constructed of extruded aluminum with an integrated probe holder. An aluminum plate attached below the case retains the probe cable. To ensure reliability in severe conditions, cover plates are gasketed and an unbreakable waterproof switch is pressure sealed at the opening. The unit is powered by a common 9V transistor battery easily accessible and removable, yet securely fixed. A single rubber encapsulated rocker switch provides on/off operation and a photocell controls the backlight for night use. Calibration can be performed without opening the case by removing two access screws. Probe Assembly termination at the circuit board is performed with a lever type terminal for quick replacement. Fahrenheit or Celsius scale is jumper selectable for versatility. LCD segments can be self tested from the circuit board to insure readout integrity. All electronic components except the probe assembly are mounted to a single circuit board eliminating wires and connectors. The instrument has been tested to be Intrinsically Safe to UL 913. | | | | | | | | | | | | | | TYPICAL APPLICATIONS Custody Transfers, Inventory, Tank, Pipeline, Barge, Ship, Railcar Tank Truck. (Recommended Operation: API 7, Intl. Safety Guide For Oil Tankers and Terminals.) | | | | | | Certifications | | | | | | | | | | | | | | Warning: This device must be ^^"^^ bonded (grounded) before and during introduction into the tank and remain bonded until complete withdrawal from the tank. | | | | | | Intrinsically Safe Thermometer Class I, Div. 1, Groups CD | | | | | | | | | | Other Applications: | | Proving Systems (API 4) Metering Systems (API 5) Metering Systems (API 6) | | | | | | Listed 29GO | | | | | | | | | | | | | | | | | | | | | | Materials: | | All petrochemicals, caustic, acid, alkalies, powders. Molasses, syrups, distilled spirits. | | | | | | | | | | | | | | ThermoProbe, Inc. 613 E. Court St. Jackson, MS 39201 USA www.thermoprobe.net | | Tel: +1 601.939.1831 Fax: +1 601.355.1831 | | | | | | | | | | | | | | © 2004 ThermoProbe, Inc. - Jackson, MS USA. All Rights Reserved. | | | | | | 05/2004 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|