Temperature controllers - 39566 TEMPERATURE CONTROLS/ TEMPERATUR-REGELGERÄTEA system of autodiagnostics assures compatibility within the programmable parameters and configuration of the instrument in order to avoid operator errors. Consequently what emerged was the fundamental data for the type of contol with " " and " " of the control's parameters. The " " is partSOFT STARTSMARTSMART of the automatic calculation of the control parameters which are obtained, as a result of the behaviour of the load (resistive) observing the fluctuation of the controlled variable, following a disturbance that happens during the process. The controls use algorithmic data of calculation stored in non volatile memory. The contol's task is to optimize the contol parameters, by using a continuous process monitoring. Eine Art von Eigendiagnose verhindert weitgehend Bedienungsfehler. Die Selbstoptimierung besteht in der automatischen Berechnung der Reglerwerte bezugnehmend auf das Verhältnis zwischen Heizelement und Werkzeugvolumen. Die Regler sind ausgestattet mit Kalkulationsalogarithmen, welche fest gespeichert sind. Deren Aufgabe ist es, die Parameter zu kontrollieren und zu regulieren. Following is an explanation of SMART.Erläuterung der beiden Parameter SMART.The action of is shown by led on display. Calculates, automatically, the parameters of regulationSMART the start of heating, in response to the demand of the process. It is essential to eliminate the overshoot of the controlled variable. Errechnet automatisch die Regler-Parameter während der Aufheizphase des Systems, die für den Prozess erforderlich sind. Dies ist wichtig, um ein Überschreiten der kontrollierten Werte zu verhindern. Die Aktion von wird durch led auf Display angezeigt ist. Rechnet automatisch die Regel-Parameter nach und paßt SMART die jeweiligen Werte an die veränderten Situationswerte oder Änderungen der Soll-Temperatur an. Controlled variable Kontrollierte Variable SOFT STARTSET POINT Is shown on the display with the initials OLH and is in %SOLLWERT of the maximum power output, for a set time to be programmed, shown on the display with the initials tOL. The " " is extremely important for the SOFT START preheating of the heaters in such a way as to not provoke a possible short cicuit due to moisture which may be present in the heaters. The value tOL shows the time during which the output is limited to the value OLH %. TIME / ZEIT This time starts if the variable measured during start up, DEPARTURE is below a threshold value calculated as a percentage of AUSGANG the "span" of the instrument. This percentage is programmed by parameter OLH. POWER OF EXIT Erscheint mit dem Kürzel PMX und in Prozent der AUSGANGSLEISTUNG Anschlußleistung für eine einstellbare Zeitspanne. Der (max power)100 % PROCESS VALUE ARBEITSTEMPERATUR " " ist besonders wichtig, um eventuell SOFT START aufgenommene Feuchtigkeit aus Hochleistungs- (max. Leistung)100 % Ausgabe 07/2007 Heizelementen verdunsten zu lassen. Wird der " SOFTSTART " nicht benutzt, wird der Isolationswiderstand verringert und das Heizelement unter Umständen Edition 07/2007 - zerstört. Der Wert PMXT zeigt die Zeit an, in welcher (power limit)15 % eine minimale Anschlußleistung PMX die Heizung des Heißkanalsystems aufheizt. (min. Leistung) 15 % TIME / ZEIT 0OHL tOL 0 25.06 |
|