Sarasota SG901 (formerly SG900) Specific Gravity Anayzer - Thermo Scientific - Process Systems - #4

/ 4


catalogue search
P. 01
P. 02
P. 03
P. 04
Pages:


See other catalogues for Thermo Scientific - Process Systems

Text version of the page
Specifications Thermo Scientific Sarasota SG901 Functional Specifications Range 0-2 SG; for any other range, consult Thermo Fisher Accuracy ±0.2% reading above 0.5 SG at reference conditions Repeatability ±0.02% span Flow Range Ideally 4 l/min to 20 l/min (0.14 ft3/min to 0.7 ft3/min) Temperature Coefficient (Corrected) 0.01%/°C (0.006%/°F) Operating Temperature Standard: -20°C to +55°C (-4°F to +131°F) or as limited by gas dew point; for other temperature ranges, consult Thermo Fisher Sample Inlet Pressure Basic system: standard 4 bar A (58 psia); for others to a maximum 20 bar (290 psi) consult Thermo Fisher Dry or wet gas system: 200 bar (2900 psi) maximum Exhaust Pressure Must be less than 4 bar A (58 psia), and less than the regulated inlet pressure by 0.4 bar A (5.8 psia) Environmental Rating IP65 (NEMA 4X) Physical Specifications Spool Materials Ni-Span C or FV520B Tubes and Fittings Materials Stainless steel (316L /1.4404) System Enclosure Materials Stainless steel Electronics Enclosure Materials Copper free aluminum grey epoxy finish; Plate glass window for headmounted electronics local display option Temperature Measurement High accuracy 1/3 DIN 4 wire PT100 (RTD) Dimensions See dimensional diagrams Net Weight Up to 60 kg (132 lb) depending on system Shipping Weight Up to 94 kg (207 lb) depending on system Shipping Dimensions 940 mm x 940 mm x 270 mm (approx 37 in x 37 in x 27 in) Installation Configuration 6.35 mm (0.25 in) tubing compression fitting Electrical Connections Instruments, IS screw terminals in FD900 terminal box (F & H versions); Heater, screw terminals in ExD enclosure Power Supply F option: frequency output Density transmitter: 16-28 VDC 10 mA average (peak 18 mA); Pressure transmitter: 9-30 VDC 20 mA H option: headmounted electronics 3 x 13-28 VDC 25 mA Outputs F option: frequency output Frequency related to density on 2 wire current modulated loop 6 mA to 18 mA; 4 wire PT100; 4-20 mA pressure H option: headmounted electronics Analog 4-20 mA related to SG, density, or density derived variable; HART protocol Compliance/Certification (pending) Quality Assurance ISO 9001:2000 CE Mark Compliant Electromagnetic Compatibility Compliant (EN 61326:1997) Pressure Equipment Directive SEP (sound engineering practice) (97/23/EC) Safe Area Use As standard BS EN ISO 15156 / Available as option NACE MR0175 Conformance ATEX Conformance: Sarasota FD900/F option (frequency output): EEx ia IIC T6 Intrinsically Safe (94/9/EC) Sarasota FD900/H option (headmounted electronics): EEx ia IIC T4 Pressure transmitter: EEx ia IIC T4 Heater: EExdp IIC T3 Canadian Standards Association (CSA) Class I, Div 1, Groups B, C & D Calibration Certification Calibration traceable to national standards. Calibration certificates supplied as standard. Optional traceable calibration equipment listing available. Materials Traceability Wetted parts traceable to BS EN 10204.3.1.b; Certification available Process Instruments www.thermo.com Unit 702-715, 7/F Tower West Yonghe Plaza No. 28, Andingmen East Street Beijing 100007 CHINA A-101, ICC Trade Tower, Senapati Bapat Road Pune 411016 Maharashtra INDIA Ion Path, Road Three, Winsford, Cheshire CW7 3GA UK 1410 Gillingham Lane Sugar Land, TX 77478 USA +86 (10) 8419-3588 +86 (10) 8419-3580 fax +91 (20) 6626 7000 +91 (20) 6626 7001 fax +44 (0) 1606 548700 +44 (0) 1606 548711 fax +1 (800) 437-7979 +1 (713) 272-0404 +1 (713) 272-4573 fax © 2009 Thermo Fisher Scientific Inc. All rights reserved. Ni-Span C is a registered trademark of the Special Metals Corporation. HART is the registered trademark of the HART Communication Foundation. Results may vary under different operating conditions. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details. Literature Code PI.2065.0109

pageCatalog pdf di En 2012-06-22-01