Specifications Functional Specifications Transducer Calibration Accuracy 2 kg/m3 (0.125 lb/ft3) and above: ±0.1% reading; below 2 kg/m3 (0.125 lb/ft3): ±0.002 kg/m3 (±0.000125 lb/ft3) Repeatability ±0.01% span Flow Range Sarasota FD900/Sarasota PD900: Ideally 4 l/min to 20 l/min (0.14 ft3/min to 0.71 ft3/min) Sarasota ID900: Normal pipeline velocities. Accuracy unaffected by velocity Operating Density Range Sarasota FD900/Sarasota ID900: 0 kg/m3 to 1000 kg/m3 (0 lb/ft3 to 62.4 lb/ft3) Sarasota PD900: 0 kg/m3 to 250 kg/m3 (0 lb/ft3 to 15.6 lb/ft3) Temperature Effect (corrected) 0.001 kg/m3/°C (0.000035 lb/ft3/°F) note: correction coefficients applied (brackets with NiSpan C sensor) Installation Ideally within 15° of vertical, for other orientations consult Thermo Fisher Density Meter Dimensions See dimensional diagrams Shipping Dimensions Sarasota FD900: 610 mm x 360 mm x 360 mm (approx 24 in x 14 in x 14 in); Sarasota ID900/fixed flange: 610 mm x 360 mm x 360 mm (approx 24 in x 14 in x 14 in); Sarasota ID900/1 m stem: 1320 mm x 230 mm x 230 mm (approx 52 in x 9 in x 9 in); Sarasota PD900: 740 mm x 320 mm x 390 mm (approx 29 in x 13 in x 15 in) Net Weight Sarasota FD900/flanged: typically 6 kg (14 lb); Sarasota ID900/fixed flange: typically 13 kg (29 lb); Sarasota ID900/1 m stem: typically 7 kg (16 lb); Sarasota PD900: typically 5 kg (11 lb) Shipping Weight Sarasota FD900/flanged: typically 7 kg (15 lb); Sarasota ID900/fixed flange: typically 15 kg (33 lb); Sarasota ID900/1 m stem: typically 8 kg (18 lb); Sarasota PD900: typically 8.5 kg (19 lb) Environmental Rating IP65 (NEMA 4X) Electrical Connections Screw terminals; Cable entry: 2 x 34-in NPT Temperature Measurement High accuracy 13 DIN integral 4-wire PT100 Local Display (H option) 412-digit 7.6 mm (0.3 in) 7-segment LCD display. Resolution 0.1% or 0.01% depending on display variable. Factory Calibration Range Depends on range selected Operating Temperature Range -20°C to +60°C (-4°F to +140°F) ambient Process Temperature Range -200°C to +200°C (-328°F to +392°F) Maximum Operating Pressure Sarasota FD900: 170 bar (2465 psi) or flange rating; Sarasota ID900: 150 bar (2175 psi) or flange rating; Sarasota PD900: standard stainless steel pocket: 100 bar (1450 psi); standard carbon steel pocket: 150 bar (2175 psi) quick response stainless steel pocket: 50 bar (725 psi); quick response carbon steel pocket: 50 bar (725 psi) Output F option (frequency output): Frequency related to density on 2-wire current modulated loop 6 mA to 18 mA; 4-wire PT100 H option (headmounted electronics): Analog 4-20 mA related to density or density derived variable; HART protocol Power Supply F option (frequency output): 13-28 VDC 10 mA average (peak 18 mA) H option (headmounted electronics): 2 x 13-28 VDC 25 mA Materials Spool Ni-Span C or FV520B Other Wetted Parts Stainless steel (316L/1.4404) Non-Wetted Parts Stainless steel (316L/1.4404) Electronics Housing Copper free aluminum grey epoxy finish; Plate glass window for local display option Pocket (Sarasota PD900 only) Standard pocket: carbon steel ASTM A350 LF2 or stainless steel 316L/1.4404 Quick response pocket: carbon steel ASTM A350 LF2 or stainless steel 316L/1.4404 Compliance/Certification Quality Assurance ISO 9001:2000 CE mark Compliant Electromagnetic Compatibility Compliant (EN 61326:1997) Pressure Equipment Directive (97/23/EC) SEP (sound engineering practice) Low Voltage Directive Compliant Safe Area Use As standard BS EN ISO 15156 / NACE MR0175 Conformance Available as option ATEX Conformance: Intrinsically Safe F option (frequency output): Ex II 1 G EEx ia IIC T6 (-20°C <_Ta <_ +60°C) (94/9/EC) H option (headmounted electronics): Ex II 1 G EEx ia IIC T4 (-20°C <_Ta <_ +60°C) Canadian Standards Association (CSA) Explosion-proof, Class I, Div 1, Groups B, C & D Calibration Certification Calibration traceable to national standards. Calibration certificates supplied as standard. Optional traceable calibration equipment listing available Material Traceability Wetted parts traceability to BS EN 10204.3.1.b; Certification available Process Instruments www.thermo.com Unit 702-715, 7/F Tower West, Yonghe Plaza No. 28, Andingmen East Street, Beijing 100007 CHINA A-101, ICC Trade Tower, Senapati Bapat Road Pune 411016 Maharashtra, INDIA Ion Path, Road Three, Winsford Cheshire CW7 3GA UNITED KINGDOM 1410 Gillingham Lane Sugar Land, TX 77478 USA +86 (10) 8419 3588 +86 (10) 8419 3580 fax +91 (20) 6626 7000 +91 (20) 6626 7001 fax +44 (0) 1606 548700 +44 (0) 1606 548711 fax +1 (800) 437-7979 +1 (713) 272-0404 +1 (713) 272-4573 fax © 2008 Thermo Fisher Scientific Inc. All rights reserved. HART is a registered trademark of the HART Communication Foundation. Ni-Span C is a registered trademark of the Special Metals Corporation. Results may vary under different operating conditions. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details. Literature Code PI.2025.1208

pageCatalog pdf di En 2012-06-22-01