Specifications
Thermo Scientific Sarasota 2000
Performance Specifications
Accuracy Overall accuracy typically 2%-5% of flow reading, depending on site conditions; Transducer frequency 2%, matched pairs to 0.5%
Velocity Range Bi-directional; Maximum depends on path length e.g., 10 m/s for 100 m path (33 ft/s for 330 ft path)
Channel Widths Suitable from 500 mm (20 in) to 200 m (650 ft)
Water Depths From 100 mm (4 in) to 20 m (65 ft), subject to channel or conduit width
Channel Shape Programmable cross section
Fluids Tolerates suspended solids up to 2,000 ppm;
Best performance achieved with minimal weed, aeration, and saline and temperature gradients
Approach Length Recommended 5 x channel width
Flowmeter Physical Specifications
Material Front opening, painted, pressed steel casing, graphics front display
Dimensions 482 mm (19.0 in) x 250 mm (9.84 in) x 408 mm (16.0 in)
Mounting Benchtop or rack mounted
Environmental Rating IP55; Requires installation within weatherproof enclosure or building
Weight Typically 18 kg (40 lb) including battery (depends on cards)
Front Display Graphics LCD; LED fault indicator
Transducer Physical Specifications
Material Encapsulated piezo-electric transducers; 250 kHz, 500 kHz: Integral drive circuits and signal amplifiers
1 MHz: drive circuit and signal amplifier inline (T Box)
Dimensions 250 kHz: 100 mm D x 75 mm L (approx 4 in x 3 in); 500 kHz: 50 mm D x 75 mm L (approx 2 in x 3 in);
1 MHz: 37 mm D x 37 mm L (approx 1.5 in x 1.5 in)
Mounting Suitable for direct pipe mounting using 'hot' or 'cold' tapping methods
Connections Cable used: URM76 with additional outer polypropylene sheath for continuous immersion with overall diameter 8 mm (0.3 in)
Star junction box (1 star box required per group of up to four connected transducers)
1 x URM76 cable per transducer connected to star box. Maximum length 5 m (approx 16 ft)
1 x URM76 cable per star box connected to flowmeter. Maximum length 300 m (approx 1000 ft)
Environmental Rating 250 kHz, 500 kHz open channel: IP68 continuous immersion to 2 bar (29 psi)
1 MHz open channel or closed conduit: IP68 continuous immersion to 15 bar (217.6 psi)
Functional Specifications
Velocity Paths/Inputs Up to 32 paths (64 transducers)
Depth Inputs Up to 16 ultrasonic depth transducers; Up to 4 analog depth inputs (programmable) via optional I/O cards
Up to 2 encoder pulsed depth inputs via optional I/O cards; Up to 2 x 16 bit digital BCD via optional I/O cards
(subject to a limit of 4 depths per channel)
Serial Communications RS232 for PC communications (1200 to 38400 baud); RS232 for modem (1200 to 19200 baud); RS485 half or full duplex
Ultrasonic Transducer Interface Cards Up to 8 velocity paths per card via multidrop facility (requires 2 transducers per velocity path)
(Minimum 1, maximum 4 per unit) Up to 4 ultrasonic depth measurements per card via multidrop facility (requires 1 transducer per depth)
Optional Input/Output Cards 2 x 12 bit analog input channels (programmable, 4-20 mA or 1-5 V);
(Maximum 2 per unit) 2 x 12 bit analog output channels (programmable, 4-20 mA or 1-5 V);
16 bit digital BCD as input or output via onboard link; Encoder pulsed input as level input
Optional Relay Card (Max. 1 per unit) 4x volt free contacts (programmable); 1x diagnostic relay output
Transducer Frequency Options 1 MHz for 1-10 m (3-30 ft) paths; 500 kHz for 5-80 m (15-260 ft) paths;
250 kHz for 50-200 m (165-655 ft) paths
Where there is overlap, the choice is governed by water conditions. Refer to ISO6416.
Operating Temperature Range Transducers: -20°C to +50°C (+4°F to +122°F); Flowmeter: -10°C to +50°C (+14°F to +122°F)
Note: LCD backlight will not turn on below 0°C (32°F); Flowmeter range subject to power supply’s operating range
Power Supply 12 VDC powered 11-16 V or 24 VDC powered 18-36 V or 85-264 VAC, 47-64 Hz with internal battery
for standby operation; Other power sources on application; Intermittent mode for low power consumption
Data Logging 1 MB capacity; Programmable for function selectable from any or all measured and calculated parameters;
Programmable sampling period 30 seconds to 30 minutes
PC Software Thermo Scientific GAFA Microsoft Windows-based PC software for local PC operation or remote PC operation via modem;
Software allows setup, diagnostics, data download, new operating software upload
Compliance
Quality Assurance ISO 9001:2000
CE mark Compliant
Flowmeter Standards Complies with ISO 6416 (equivalent to BS3680 pt 3E); complies with CEI IEC 41 Third Edition 1991-11
Safe Area Use As standard
Hazardous Area Use Applicable to 1 MHz transducers only via 1 x barrier per transducer; Subject to cable restrictions
Transducer: (Epsilon 06 ATEX 2041) II 2 G EEx ib IIB T4; Interface: (Epsilon 06 ATEX 2041) II (2) G [EEx ib] IIB
Communications Protocols RTU; ASCII Modbus
Process Instruments www.thermo.com
Unit 702-715, 7/F Tower West
Yonghe Plaza No. 28, Andingmen East Street
Beijing 100007 CHINA
A-101, ICC Trade Tower, Senapati Bapat Road
Pune 411016 Maharashtra INDIA
Ion Path, Road Three,
Winsford, Cheshire CW7 3GA UK
1410 Gillingham Lane
Sugar Land, TX 77478 USA
+86 (10) 8419-3588
+86 (10) 8419-3580 fax
+91 (20) 6626 7000
+91 (20) 6626 7001 fax
+44 (0) 1606 548700
+44 (0) 1606 548711 fax
+1 (800) 437-7979
+1 (713) 272-0404
+1 (713) 272-4573 fax
© 2008 Thermo Fisher Scientific Inc. All rights reserved. Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries. Results may vary
under different operating conditions. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details.
Literature Code PI.2020.0408
|
|