You may also be interested in
Level sensor, In-line density meter, On-line analyzer, Flow-meter, Calculator
Text version of the page
Specifications
Thermo Scientific Ramsey Granucor DK13
General Specifications
Sensor Size DN10 to DN200 (0.5 in to 8.0 in)
Tube Material Steel, painted (stainless steel optional)
Fittings Flanges, DIN or ANSI 150 lb, small tongue and groove
Permissible Temperature Range In Measuring Tube: <149°C (<300°F)
Ambient Temperature: -20°C to +60°C (-4° to +140°F)
Storage Temperature: -40°C to +74°C (-40°F to +165°F)
Power Supply Must be specified when ordering system
Alternate Current: 110V, 115V, 220V, 230V; +15 to -10%, 50/60 Hz
Direct Current: 24 VDC
Power Consumption: Maximum 4.5 VA
Empty Pipe Capacitance Approximately 40 pF
Capacitance in Full Pipe Depends on solids
Bandwidth of Output Signal Up to 5 kHZ
Solids Loading ì: Minimum 5 to 1 (mass ratio solids/gas)
Signal Transmission Cable 3-wire unshielded, 25 W per wire maximum resistance,
1000 foot maximum
Installation Position Vertical, with material flow downward, if possible
Upstream Length 20 diameters of straight pipe is required
Downstream Length 10 diameters of straight pipe is required
Approvals CSA Approved for Class I Groups B,C,D;
Class II Groups E,F,G; Class III on AC versions
Thermo Scientific Ramsey Granucor DC13
General Specifications
Sensor Size DN10 to DN200 (0.5 in to 8.0 in)
Tube Material Steel, painted (stainless steel optional)
Fittings Flanges, DIN or ANSI 150 lb, small tongue and groove
Permissible Temperature Range In Measuring Tube: <149°C (<300°F)
Ambient Temperature: -20°C to +60°C (-4°F to +140°F)
Storage Temperature: -40°C to +74°C (-40°F to +165°F)
Power Supply Must be specified when ordering system
Alternate Current: 110V, 115V, 220V, 230V; +15 to -10%, 50/60 Hz
Direct Current: 24 VDC
Power Consumption: Maximum 4.5 VA
Frequency 56 to 2600 Hz
Solids Loading ì Minimum 5 to 1 (mass ratio solids/gas)
Empty Pipe Capacitance Approximately 0.75 pF
Response Time <1 second
Signal Transmission Cable 2-wire unshielded, 25 W per wire maximum resistance,
1000 foot maximum
Installation Position Vertical, with material flow downward, if possible
Upstream Length 20 diameters of straight pipe is required
Downstream Length 10 diameters of straight pipe is required
Approvals CSA Approved for Class I Groups B,C,D;
Class II Groups E,F,G; Class III on AC versions
Australia
+61 (0) 8 8208 8200
+61 (0) 8 8234 3772 fax
Canada
+1 (905) 888-8808
+1 (905) 888-8828 fax
Chile
+56 (0) 2 378 8050
+56 (0) 2 370 1082 fax
China
+86 (0) 21 6865 4588
+86 (0) 21 6445 7830 fax
Germany
+49 (0) 208-824930
+49 (0) 208-852310 fax
India
+91 (20) 6626 7000
+91 (20) 6626 7001 fax
Italy
+39 02-959514-1
+39 02-953200-15 fax
Netherlands
+31 (0) 76-579-5555
+31 (0) 76-571-4958 fax
South Africa
+27 (0) 11-609-3101
+27 (0) 11-609-3110 fax
Spain
+34 (0) 91-484-5965
+34 (0) 91-484-3597 fax
United Kingdom
+44 (0) 1788-820300
+44 (0) 1788-820301 fax
United States
+1 (800) 445-3503
+1 (763) 783-2525 fax
+1 (763) 783-2500 direct
© 2008 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Results may vary under different operating conditions.
Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Literature Code PI.8033.1108
Process Instruments www.thermo.com/bulk-handling
DC13 and DK13 Application
10 to 20 x Dia.
(Internal) Inlet Run
5 to 10 x Dia.
(Internal) Outlet Run
521 mm (20.5 in)
DC13
DK13
Solids
Velocity
Solids
Concentration
MicroTech 2109 / 3109
Correlator / Integrator
System
Alarm / Analog
(Flow Rate Velocity
or Concentration)
Pulsed
Bus
|
|