Specifications Thermo Scientific Ramsey Granucor DK13 General Specifications Sensor Size DN10 to DN200 (0.5 in to 8.0 in) Tube Material Steel, painted (stainless steel optional) Fittings Flanges, DIN or ANSI 150 lb, small tongue and groove Permissible Temperature Range In Measuring Tube: <149°C (<300°F) Ambient Temperature: -20°C to +60°C (-4° to +140°F) Storage Temperature: -40°C to +74°C (-40°F to +165°F) Power Supply Must be specified when ordering system Alternate Current: 110V, 115V, 220V, 230V; +15 to -10%, 50/60 Hz Direct Current: 24 VDC Power Consumption: Maximum 4.5 VA Empty Pipe Capacitance Approximately 40 pF Capacitance in Full Pipe Depends on solids Bandwidth of Output Signal Up to 5 kHZ Solids Loading ì: Minimum 5 to 1 (mass ratio solids/gas) Signal Transmission Cable 3-wire unshielded, 25 W per wire maximum resistance, 1000 foot maximum Installation Position Vertical, with material flow downward, if possible Upstream Length 20 diameters of straight pipe is required Downstream Length 10 diameters of straight pipe is required Approvals CSA Approved for Class I Groups B,C,D; Class II Groups E,F,G; Class III on AC versions Thermo Scientific Ramsey Granucor DC13 General Specifications Sensor Size DN10 to DN200 (0.5 in to 8.0 in) Tube Material Steel, painted (stainless steel optional) Fittings Flanges, DIN or ANSI 150 lb, small tongue and groove Permissible Temperature Range In Measuring Tube: <149°C (<300°F) Ambient Temperature: -20°C to +60°C (-4°F to +140°F) Storage Temperature: -40°C to +74°C (-40°F to +165°F) Power Supply Must be specified when ordering system Alternate Current: 110V, 115V, 220V, 230V; +15 to -10%, 50/60 Hz Direct Current: 24 VDC Power Consumption: Maximum 4.5 VA Frequency 56 to 2600 Hz Solids Loading ì Minimum 5 to 1 (mass ratio solids/gas) Empty Pipe Capacitance Approximately 0.75 pF Response Time <1 second Signal Transmission Cable 2-wire unshielded, 25 W per wire maximum resistance, 1000 foot maximum Installation Position Vertical, with material flow downward, if possible Upstream Length 20 diameters of straight pipe is required Downstream Length 10 diameters of straight pipe is required Approvals CSA Approved for Class I Groups B,C,D; Class II Groups E,F,G; Class III on AC versions Australia +61 (0) 8 8208 8200 +61 (0) 8 8234 3772 fax Canada +1 (905) 888-8808 +1 (905) 888-8828 fax Chile +56 (0) 2 378 8050 +56 (0) 2 370 1082 fax China +86 (0) 21 6865 4588 +86 (0) 21 6445 7830 fax Germany +49 (0) 208-824930 +49 (0) 208-852310 fax India +91 (20) 6626 7000 +91 (20) 6626 7001 fax Italy +39 02-959514-1 +39 02-953200-15 fax Netherlands +31 (0) 76-579-5555 +31 (0) 76-571-4958 fax South Africa +27 (0) 11-609-3101 +27 (0) 11-609-3110 fax Spain +34 (0) 91-484-5965 +34 (0) 91-484-3597 fax United Kingdom +44 (0) 1788-820300 +44 (0) 1788-820301 fax United States +1 (800) 445-3503 +1 (763) 783-2525 fax +1 (763) 783-2500 direct © 2008 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Results may vary under different operating conditions. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Literature Code PI.8033.1108 Process Instruments www.thermo.com/bulk-handling DC13 and DK13 Application 10 to 20 x Dia. (Internal) Inlet Run 5 to 10 x Dia. (Internal) Outlet Run 521 mm (20.5 in) DC13 DK13 Solids Velocity Solids Concentration MicroTech 2109 / 3109 Correlator / Integrator System Alarm / Analog (Flow Rate Velocity or Concentration) Pulsed Bus

pageCatalog pdf di En 2012-06-22-01