mo Scientific M-PULSe — Multi-Path Ultrasonic Liquid Flow Measurement System
General Specifications
Accuracy
±0.10% over 10:1 flow range of measured value; ±0.15% over 20:1 flow range of measured value
Repeatability
±0.02% of measured value
Flow Range
+0.6 m/second to +12.2 m/second (2 ft/second to 40 ft/second) automatic bi-directional detection
Viscosity Range
Up to 1500 cSt
Operating Temperature
-40°C to +85°C (-40°F to +185°F) - Electronics
Fluid Temperature
-40°C to +120°C (-40°F to +248°F) - Transducers
Number of Ultrasonic Paths
4
History
Data log interval 1 minute to 60 minutes, Audit trail, Alarms
Units
Imperial or metric
Flow Computer
Volumetric Correction
Implements API Ch11.1 2004. Relative density range 0.61120 to 1.16464
Low Density Fluids Calculation
Implements API TP25. Low density range extended to 0.3500 with Pressure Correction to API Ch11.2.1
Batch Options
Manual; Daily; Timed; Fixed Quantity; Multi-product
Self Proving
Works with uni-directional or bi-directional prover, small volume prover
Line Density Input Options
4-20 mA input or interfaces with Solartron, Thermo Scientific Sarasota or UGC density meters
User Interfaces
Keyboard
4x4, metal
LCD
16x4, -20°C to +70°C (-4°F to +158°F)
Software
Thermo Scientific AutoM-PULSe, through RS232 or RS485 port
User Programming Interface
RTU and ASCII Modbus protocol
Input/Output
Serial Ports
1 RS232: local; 2 RS232/RS485 (2-wire/4-wire)
Ethernet Port
1 port, 10/100 Mbps
A/D Converter
-0.5-5.5 V span, 14 bit A/D
Analog Input
3 x 4-20 mA inputs; one 1-5 V input
RTD Input
2 PT100 4-wire RTD inputs can be used via an interface to 2 of the 4-20 mA inputs
Density Input
2 density meter period current pulse inputs
Analog Output
1 electrically isolated 4-20 mA port with separate 24 VDC 20 mA source
Digital Output
3 solid-state relays for 250 VAC/DC, 0.1A; 1 FET, open drain
Pulse Output
1 frequency output: 0-10 KHz, with 2 outputs 90 degrees out of phase
Prover Input
2 sphere detect lines
Prover Output
4 valve control lines
Totalizer Output
2 software configurable pulse outputs
Power Supply
Power Input
10-30 VDC or 100-240 VAC
Current Draw
10-30 VDC: less than 2A; 100-240 VAC: less than 0.5 A
Safety Specifications
NEMA/IP Rating
NEMA 4X/IP65
North American Hazardous
Transducer: Class I Div 1 Groups C & D
Area Certification
Electronic Enclosure: Class I Div 2 Groups C & D
ATEX Hazardous Area Certification
Transducer: II 1 G EEx ia IIB T4 (Zone 0); Electronics Enclosure: II 3 (1) G EEx nL (ia) IIB T4 (Zone 2)
European Compliance
CE
Pressure Vessel
Meter body designed and manufactured in accordance with ASME B31.3 Process Piping Code
and the Pressure Equipment Directive (PED) 97/23/EC
Typical Accuracy/Linearity (8-inch Example)
M-PULSe Junction Box
0.E 0.4 0.3 0.2
^ 0.'
Ë 0
LlJ-0.1
-0.2 -0.3 -0.4 -0.E
Heavy Crude
0
10
15
20 25 30 Flow Velocity (ft/s)
35
40
45
Custody Transfer Approval OIML R 117 class 0.3 (1995)
© 2009 Thermo Fisher Scientific Inc. Ai! rights reserved. Ai! trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Resuits may vary under différent operating conditions. Specifications, terms andpricing are subject to change. Not ai! products are avaiiabie in ai! countries. Piease consuit your local saies representative for detaiis. Literature Code PI.2040.0309
Process Instruments
Unit 702-715, 7/F Tower West
Yonghe Plaza No. 28, Andingmen East Street
Beijing 100007 CHINA
A-101, ICC Trade Tower, Senapati Bapat Road Pune 411016 Maharashtra INDIA
Ion Path, Road Three, Winsford, Cheshire CW7 3GA UK
1410 Gillingham Lane Sugar Land, TX 77478 USA
+86 (10) 8419-3588
+86 (10) 8419-3580 fax
+91 (20) 6626 7000 +91 (20) 6626 7001 fax
+44 (0) 1606 548700 +44 (0) 1606 548711 fax
+1 (800) 437-7979 +1 (713) 272-0404 +1 (713) 272-4573 fax
Thermo
SCIENTIFIC

pageCatalog pdf di En 2012-06-22-01