Functional Specifications
Accuracy Liquids: ±2.0% of reading achievable (10 to 1 turndown)
Gases: ±2.0% of reading achievable (5 to 1 turndown)
Repeatability 0.2%
Pressure Drop Liquids: Typically 300 mbar (1 psi) at normal maximum flow rate in water
Gases: Negligible at 100% flow rate dependent on gas density
Maximum Pressure 270 psig (18 bar)
Maximum Process Temperature 150°C (300°F)
Physical Specifications
Materials Seal housing: Carbon steel (standard) or stainless steel
Flanges: Forged carbon steel or stainless steel
Shaft and sleeve bearings: Tungsten carbide and durable alloy
Ball bearings: Stainless steel ANSI 440C
Installation Install in pipeline with at least 10 pipe diameters of straight length upstream and 5 diameters downstream of flowmeter.
Outputs
Standard Pickup 100 m V pulse peak-to-peak at 1 m/s (3 ft/s)
Process Instruments www.thermo.com
Room 1010 - 1019
Ping’an Mansion No. 23 Jinrong Street
Xicheng Dist, Beijing 100032 CHINA
A-101, ICC Trade Tower, Senapati Bapat Road
Pune 411016 Maharashtra, INDIA
Ion Path, Road Three, Winsford
Cheshire CW7 3GA UNITED KINGDOM
1410 Gillingham Lane
Sugar Land, TX 77478 USA
+86 (10) 5850-3588
+86 (10) 6621-0847 fax
+91 (20) 6626 7000
+91 (20) 6626 7001 fax
+44 (0) 1606 548700
+44 (0) 1606 548711 fax
+1 (800) 437-7979
+1 (713) 272-0404
+1 (713) 272-4573 fax
©2007 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Results may vary under different operating conditions.
Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details. Literature Code PI.2036.0207
Model 5400 — Insertion Turbine Flowmeter for Low Flow Liquids
Functional Specifications
Accuracy Liquids: ±2.0% of reading achievable (5 to 1 turndown)
Repeatability 0.2%
Pressure Drop Liquids: Typically 300 mbar (1 psi) at normal maximum flow rate in water
Gases: Not available
Maximum Pressure 225 psig (15 bar)
Maximum Process Temperature 150°C (300°F)
Physical Specifications
Materials Seal housing: 316 stainless steel
Shaft and sleeve bearings: Tungsten carbide and durable alloy
Installation Install in pipeline with at least 10 pipe diameters of straight length upstream and 5 diameters downstream of flowmeter.
Outputs
Standard Pickup 100 mV pulse peak-to-peak at 1 m/s (3 ft/s)
|
|