Temperature measuring testo 925 - For fast and reliable measurements in the HVAC field Ideally suited to applications in the HVAC field 1-channel temperature measuring instrument with optional wireless probes TopSafe, the indestructible protective case, protects from Continuous display of min/max values Audible alarm (adjustable limit values) Hold-button for freezing measurement values Large, backlit display The testo 925 is a 1-channel temperature measuring instrument which is particularly suitable for applications in the HVAC field. The instrument is optimum for the connection of fast and reliable thermocouple probes. Using measurement data transfer by radio, the measurement value of a further temperature probe can be additionally displayed wirelessly. The protective cover TopSafe ensures water- and dirt-proofness when a probe is connected. The instrument reliably and continuously displays the minimum and maximum measurement values. The measurement values shown in the display (current measurement value, frozen measurement value, or the minimum/maximum values) can be printed out via the Testo report printer (optional). The user can store limit values in the instrument himself; as soon as these upper and lower values are violated, an audible signal sounds.
Open the catalog to page 1Technical data testo 925, 1 channel temperature measuring instrument T/C Type K, audible alarm, connection of an optional radio probe, with battery and calibration protocol Sensor type Type K (NiCr-Ni) General technical data Battery life 200 h (connected probe, backlight off) 45 h (radio mode, backlight off) 68 h (connected probe, backlight always on) 33 h (radio mode, backlight always on) The testo 925 is a 1-channel temperature measuring instrument which is particularly suitable for applications in the HVAC field. The instrument is optimum for the connection of fast and reliable...
Open the catalog to page 2Accessories for measuring instrument Part no. Radio module for upgrading measuring instrument with radio option Other features Calibration Certificates
Open the catalog to page 3Radio probes Radio probes for immersion/penetration measurements Radio immersion/penetration probe, NTC, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, Radio immersion/penetration probe, NTC, approval for USA, CA, CL; Radio freq. 915.00 MHz FSK Radio handles with probe head for air-/ immersion-penetration-meas. Radio handle for plug-in probe heads, ind. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, T/C probe head for air/immersion/penetration measurement, attachable to radio handle, T/C Type K Radio handle for plug-in probe heads,...
Open the catalog to page 4Probe type Probe shaft/probe shaft tip * Robust air probe, T/C Type K, Immers./penetr. probes Surface probes 6 The measuring instrument inside TopSafe is waterproof with this probe. 1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K). A probe always corresponds to only one accuracy class.
Open the catalog to page 5Probe type Probe shaft/probe shaft tip Surface probes è The measuring instrument inside TopSafe is waterproof with this probe. 1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K). A probe always corresponds to only one accuracy class.
Open the catalog to page 6Probe type Probe shaft/probe shaft tip Food probes è The measuring instrument inside TopSafe is waterproof with this probe. 1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K). A probe always corresponds to only one accuracy class. Information on surface measurement: • The response times tgg stated are measured on ground steel or aluminium plates at +60 °C. • The stated accuracies are sensor accuracies. • The accuracy in your application is dependent on the surface structure...
Open the catalog to page 7testo 925 12:33 Seite 8 We measure it. 0981 9314/msp/A/05.2012 17.08.2012 Subject to change without notice. testo-925-P08 www.testo.com
Open the catalog to page 8All TESTO catalogs and technical brochures
-
First choice for every job
8 Pages
-
Thermal imager testo 883
4 Pages
-
testo 317-3
4 Pages
-
testo 316-1
8 Pages
-
testo-315-3
4 Pages
-
Digital manifold
4 Pages
-
Gas leak detectors
8 Pages
-
Flue gas analyzer
4 Pages
-
testo 440
12 Pages
-
testo 400
12 Pages
-
Digital multimeter
2 Pages
-
Testo Smart Probes
8 Pages
-
Product brochure testo Saveris
24 Pages
-
testo-570-Datasheet EN
4 Pages
-
Brochure_Refrigeration_EN
16 Pages
-
Datasheet-testo-557-NEW-EN
4 Pages
-
Datasheet-testo-550-NEW-EN
4 Pages
-
Datasheet-testo-549-NEW-EN
4 Pages
-
Brochure-testo-Saveris-2_EN
12 Pages
-
testo-Saveris-2-Datasheet_EN
8 Pages
-
Huminator
2 Pages
-
Digital manifold - testo 570
4 Pages
-
Digital manifold - testo 557
4 Pages
-
Digital manifold - testo 550
4 Pages
-
Hand stroboscope - testo 476
2 Pages
-
Vane anemometer - testo 417
2 Pages
-
Vane anemometer - testo 416
2 Pages
-
Vane anemometer - testo 410
2 Pages
-
SO2 analyzer - testo 325-I
2 Pages
-
Fiberscope - testo 319
2 Pages
-
Smoke tester- testo 308
4 Pages
-
Mini alarm thermometer
2 Pages
-
Software for data loggers
4 Pages
-
Humidity generator
2 Pages
-
stationary temperature probe
10 Pages