| | | 42 | | |
| | | |
| | | îygrotesl | | |
| | | |
| | | W - Wall mounting | | D - Duct mounting ë | | P - Probe with cable | | |
| | | | | |
| | | |
| | | |
| | | testo humidity sensor + Pt1000 | | |
| | | |
| | | |
| | | |
| | | i i | | |
| | | Stainless stee probes up to 120°C | | |
| | | Stainless steel probes up to 180°C | | |
| | | |
| | | |
| | | |
| | | Channel 1+2 (WHT) -65 mm stainless steel probe I testo humidity sensor + Pt1000 | | |
| | | Channel 1+2 (DHT) HP heated probe | | |
| | | |
| | | |
| | | Cable (250 to 10,000 mm) to probe | | |
| | | |
| | | Broad selection of displays (optional, also for W/D versions) Control menu via 3 external buttons All hygrotest units are configured to customer specification. From the options below, please select the solution that meets your requirements, for example, a hygrotest 650 with probe on cable, output signal 0 to 20 mA, 150 mm long probe, 8 m long cable, measurement uncertainty 1% RH, open metal protection cage, H6 display, Channel 1: 0 to 45 g/m3, Channel 2: 20 to 160 °C This results in the following order code: hygrotest 650 PHT -20/180 / B4 / C2 / 150 / D2 / 8000 / F2 / G4 / H6 / K2 / 0 / 45 / L5 / M2 / 20 / 160 / N1 I_I I_I * * | | |
| | | |
| | | hygrotest 650 | | |
| | | |
| | | Versions Wall-mounted, output %RH + T*** WHT -20/70 Duct-mounted, outputs %RH + T DHT -20/120 Probe version, output %RH + T PHT -40/80 Probe version, output %RH + T PHT -40/120 Probe version, output %RH + T PHT -20/180 Heated version, output %RH + T HP -20/120 | | |
| | | Scaling, channel 2 M1 Standard scale, Channel 2 (min ..max = -20 to 70/120/180 °C) M2 Special scale, Channel 2 ( min ..max) * + N1°C |N2°F (e.g. "M2 30 to 60 N2" for 30 to 60 °F) ||N3°Ctd N4°Ftd * Give scaling limits ! N5g/kg N6g/m3 N7WB°C N8WB°F | | |
| | | |
| | | |
| | | WB = wet bulb temperature | | |
| | | |
| | | Analog outputs 4 to 20 mA (2-wire). (not with HP) 0 to 1 V (4_wire) 0 to 10 V (4-wire) 0 to 20 mA (4-wire) 4 to 20 mA (4-wire, only with HP) | | |
| | | Scaling, channel 1 K1 Standard scale, channel 1 (min to max = 0 to 100 % RH)
| | |
| | | B1 B2 B3 B4 B5 | | |
| | | |
| | | K2 Special scale, channel 1 (min to max) * (e.g. "K2 20 to 80 L1" for 20 to 80%RH) * Give scaling limits ! | | L1 %RH L2 °Ctd L3 °Ftd |L4 g/kg L5 g/m3 L6 WB°C L7 WB°F | | |
| | | |
| | | |
| | | |
| | | |
| | | WB = wet bulb temperature H2 H3 H4 H5 H6 H8 2) H9 2) | | |
| | | Probes and cable length Standard probe length (W: 65 mm, D/P/HP: 210 mm) C1 Special probe length (80 to 800 mm, W/D/P versions) C2 Standard cable length (only P and HP versions, 2 m) D1 Special cable length (0.8 to 10 m, P versions)** D2 Humidity adjustment 2% RH (not for HP or H2O2)|F1 Humidity adjustment 1% RH (not for HP) F2 Humidity adjustment 2.5% RH (only in HP, not for H2O2)F4 | | |
| | | Display versions | | H- | | |
| | | |
| | | | | | | | | | | | | | | | Display supplied via transmitter x | | x | | | | | | | | | External display supply | x | | x | x | x | x | x | | | | 2x2 switch outputs | | | | x | x | | | | | | Analog outputs 2 | 2 | | 2 | 2 | 2 | 3 | 3 | | | | RS485 | | x | x | x | | x | 2 | | | | Analog input channels | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | |
| | | Sensor filters 1) Sintered stainless steel filter G1 Wire mesh protective filter G2 Teflon sintered filter G3 Metal protective filter, open G4 Teflon sintered filter with drip hole G6 Condensation protection and Teflon sintered filter with drip hole G7 Filter for H2O2 atmospheres 2) G8 1) for selection cf. page 35 below 2) for H2O2 applications cf. page 46. Not with adjustment code F1 or F4, not with HP version, only with H8 display. | | |
| | | WHT | | DHT/PHT | | HP | | |
| | | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |