Catalogue Stationary Solutions for Air Conditioning and Process
www.testo.com
print switch display
Page / 120
Make a request   
TESTO - 2090
/ 120
See other catalogues for TESTO
Text version of the page
42
îygrotesl
W - Wall mounting
D - Duct mounting ë
P - Probe with cable
testo humidity sensor + Pt1000
testo humidity sensor + Pt1000
i i
Stainless stee probes up to 120°C
Stainless steel
probes
up to 180°C
Channel 1+2 (WHT) -65 mm stainless steel probe
I testo humidity sensor + Pt1000
Channel 1+2 (DHT)
HP heated probe
Cable (250 to 10,000 mm) to probe
Broad selection of displays (optional, also for W/D versions) Control menu via 3 external buttons
All hygrotest units are configured to customer specification.
From the options below, please select the solution that meets your requirements, for example, a hygrotest 650 with probe on cable, output signal 0 to 20 mA, 150 mm long probe, 8 m long cable, measurement uncertainty 1% RH, open metal protection cage, H6 display, Channel 1: 0 to 45 g/m3, Channel 2: 20 to 160 °C
This results in the following order code:
hygrotest 650 PHT -20/180 / B4 / C2 / 150 / D2 / 8000 / F2 / G4 / H6 / K2 / 0 / 45 / L5 / M2 / 20 / 160 / N1
I_I I_I
* *
hygrotest 650
Versions
Wall-mounted, output %RH + T*** WHT -20/70
Duct-mounted, outputs %RH + T DHT -20/120
Probe version, output %RH + T PHT -40/80
Probe version, output %RH + T PHT -40/120
Probe version, output %RH + T PHT -20/180
Heated version, output %RH + T HP -20/120
Scaling, channel 2
M1 Standard scale, Channel 2 (min ..max = -20 to 70/120/180 °C) M2 Special scale, Channel 2 ( min ..max) * + N1°C |N2°F (e.g. "M2 30 to 60 N2" for 30 to 60 °F) ||N3°Ctd N4°Ftd * Give scaling limits ! N5g/kg N6g/m3
N7WB°C N8WB°F
WB = wet bulb temperature
Analog outputs
4 to 20 mA (2-wire). (not with HP)
0 to 1 V (4_wire)
0 to 10 V (4-wire)
0 to 20 mA (4-wire)
4 to 20 mA (4-wire, only with HP)
Scaling, channel 1
K1 Standard scale, channel 1 (min to max = 0 to 100 % RH)
B1
B2 B3 B4 B5
K2 Special scale, channel 1 (min to max) *
(e.g. "K2 20 to 80 L1" for 20 to 80%RH)
* Give scaling limits !
L1 %RH L2 °Ctd L3 °Ftd |L4 g/kg L5 g/m3 L6 WB°C L7 WB°F
WB = wet bulb temperature
H2 H3 H4 H5 H6 H8 2) H9 2)
Probes and cable length
Standard probe length (W: 65 mm, D/P/HP: 210 mm) C1 Special probe length (80 to 800 mm, W/D/P versions) C2 Standard cable length (only P and HP versions, 2 m) D1 Special cable length (0.8 to 10 m, P versions)** D2
Humidity adjustment 2% RH (not for HP or H2O2)|F1 Humidity adjustment 1% RH (not for HP) F2
Humidity adjustment 2.5% RH (only in HP, not for H2O2)F4
Display versions
H-
Display supplied via transmitter x
x
External display supply
x
x
x
x
x
x
2x2 switch outputs
x
x
Analog outputs 2
2
2
2
2
3
3
RS485
x
x
x
x
2
Analog input channels
Sensor filters 1)
Sintered stainless steel filter G1
Wire mesh protective filter G2
Teflon sintered filter G3
Metal protective filter, open G4
Teflon sintered filter with drip hole G6
Condensation protection and Teflon sintered filter with drip hole G7
Filter for H2O2 atmospheres 2) G8
1) for selection cf. page 35 below
2) for H2O2 applications cf. page 46. Not with adjustment code F1 or F4, not with HP version, only with H8 display.
WHT
DHT/PHT
HP
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-120
pdf-page pdf di En 2008-10-42-13