Catalogue Stationary Solutions for Air Conditioning and Process
www.testo.com
print switch display
Page / 120
TESTO - 2090, 40301, 157537
/ 120
See other catalogues for TESTO
Text version of the page

40

hygrotest 600: Standard humidity measurement transmitter for air conditioning and process

W - wallD - duct P - probe with cable

testo humiditysensor + NTC Channel 2 (WHT) testo humidity sensor + NTC Channel 1 (WH+WHT) 65 mm plastic probe Channel 1 (DH+DHT)Channel 2 (DHT) Channel 1+2 (PHT)Plastic probes(PHT -20/70) orstainless steelprobes (PHT -20/120) testo humidity sensor + NTC 200 mm probe made ofplastic (DH/DHT -20/70) stainless steel (DHT -20/120) Cable (250...2000 mm) Wide selection of displays (optional, also for W/D versions) User menu via 3 interior buttons

All h hygrotest h humidity m measurement t transmitters a are c customer -s specifically c configured. Please choose the solution suited to you from the options below, for example a hygrotest 600 with a probe on a cable, standard cable length 2 metres,standard probe length 210 mm, teflon filter, display H5, -30 to +50 °Ctd (dewpoint) as output channel 1, -20 to +120 °C as output channel 2.This results in the following order code:hygrotest 600 PHT -20/120 / C1 / D1 / G3 / H5 / K2 / -30 / 50 / L2 / M1

*

0555 0600 hygrotest 600

Versions Probe and cable length Sensor filtersWDH/DHT/PHT Scaling channel 2Scaling channel 1 Wall-mounted, output %RHWHWall-mounted, outputs %RH + TWHT -20/70 Duct-mounted, output %RHDH Duct-mounted, outputs %RH + TDHT -20/70 Duct-mounted, outputs %RH + TDHT -20/120Probe version, outputs %RH + TPHT -20/70Probe version, outputs %RH + TPHT -20/120 Stainless steel sintered filterG1Metal wire protective filterG2 Teflon sinter filterG3 Metal protective cap, openG4 Plastic cap (ABS), openG5
M1Stand. scale chann. 2 (4 to 20 mA = -20 to 70/120 °C)M2Spec. scale chann. 2 (4 to 20 mA = min to max*) +N1°C(e.g. “M2 30...60 N2” for 30 to 60 °FN2°F K1Stand. scale chann. 1 (4...20 mA = 0 to 100 %RH)K2Spec. scale chann. 1 (4 to 20 mA 0 min to max* +L1 %RH(e.g.”K2 20 to 80 L1” for “20 to 80 %RH)L2 dewp. °C * Please name scaling limits!L3 dewp. °F Standard probe length (W: 65 mm, D: 200 mm, P: 210 mm)C1(DHT -20/70: 100 mm)(PHT -20/120: 210 mm)Special length stainless steel probe C2 (DHT -20/120: 100 to 800 mm) (PHT -20/120: 150 to 800 mm) Standard cable length (P-versions only, 2 m)D1 Special cable length /0.25 to 2 m P-versions)D2 Special cable length 5 m (PHT)D2 Display v versions ( (cf. p p.20) H1H2H3H4H5H6 Display supplied by transmitter External display supply 2 x 2 switch outputs Analog outputs RS485xxxxxxxxxxxxxxxx
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-120