| | | 20 | | |
| | | |
| | | The humidity measurement transmitter for critical climate (testo 6651) is generally customer-specifically configured, adjusted and delivered. Please select the measurement transmitter you require step by step. | | |
| | | |
| | | 0555 6651 A01 Bxx Cxx Dxx Exx Fxx Gxx Hxx Ixx Jxx Kxx | | |
| | | |
| | | 4 to 20 mA (2-wire, 24 VDC), not possible with relays 0 to 1 V (4-wire, 24 VAC/DC) 0 to 5 V (4-wire, 24 VAC/DC) 0 to 10 V (4-wire, 24 VAC/DC) 0 to 20 mA (4-wire, 24 VAC/DC) 4 to 20 mA (4-wire, 24 VAC/DC) | | |
| | | B01 B02 B03 B04 B05 B06 | | |
| | | Order example measurement transmitter testo 6651 Housing with display with menu in English 4 to 20 mA (2-wire) Cable input M16/M20 Factory setting channel 1: %RH with scaling min 0 %, max 100 %* Factory setting channel 2: °C with scaling min -10 °C, max 70 °C* without relay Instruction manual in German + English — 0555 6651 A01 / B01 / C03 / D01 / F01 / G02 / -10 / +70 / H00 / K01 | | |
| | | |
| | | |
| | | C00 C02 C03 C04 C05 C06 C07 | | Without display With display / English With display / German With display / French With display / Spanish With display / Italian With display / Japanese | | |
| | | Clear-text language. |— Operating menu available only with display | | |
| | | |
| | | |
| | | |
| | | |
| | | Cable input M16 (relay: M20) Cable input NPT //" Cable contact via via M plug connection for signal and supply (for optional relays: M20 cable input) | | |
| | | D01 D02 D03 | | |
| | | |
| | | |
| | | | | | | | | | F01 | %RH / min / max | | | | F02 | °C / min / max | | | | F03 | °F / min / max | | | | F04 | °Ctd / min / max | | | | F05 | °Ftd / min / max | | | | | | | | G01 | %RH / min / max | | | | G02 | °C / min / max | | | | G03 | °F / min / max | | | | G04 | °Ctd / min / max | | | | G05 | °Ftd / min / max | | | | | | | | | |
| | | h Channel 1* | | |
| | | |
| | | ' The standard scaling is delivered, as long as "min" and "max" are not specified. | | |
| | | |
| | | Channel 2* | | |
| | | |
| | | |
| | | H00 Without relay not with code "B01" H01 4 relay outputs, limit value monitoring - Relay parameterization when commissioning H02 4 relay outputs, limit values channel 1 + collective alarm _ via operating menu (display) or P2A software | | |
| | | |
| | | K01 IM German-English K02 IM French-English K03 IM Spanish-English K04 IM Italian-English K05 IM Dutch-English K06 IM Japanese-English K07 IM Chinese-English | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |