42 Overview: Pro humidity data logger testostor 171 TypeDescription
Illustration
Measurement value sensorMeas. rangeResolution
Accuracy
MemoryMeasuring rate
Oper. temp.
Storage temp.Battery typeBattery life
Dimensions
Weight testostor 171-1 testostor 171-6 testostor 171-2 testostor 1722 testostor 171-3 Ex 171-3 > Internal °C NTC +external °C NTC or
%RH/°C2 x external %RH / °Cor °C, tdInternal: %RH, °C, tdInternal: %RH, °C, tdwith alarm outputInternal %RH / °C20,000 readingsInternal %RH / °Cwith Ex approval NTC (Temperatureprobe)
NTC (Combi-probe°C/%RH)0 to+100 %RH-35 to+70 °C-50 to+120 °C0.1 %RH0.1 °C0.1 °C
55000Readings2 sto24 h-35 to+70 °C-40 to+85 °C
Lithium batteryup to 5 years131 x 68 x 26 mm 305 gIP65
2 years NTC (temperatureprobe)
NTC (combi-probe°C/%RH)0 to+100 %RH-50 to+120 °C-30 to+50 °Ctd0.1 %RH0.1 °C
55000Readings2 sto24 h-20 to+70 °C-40 to+85 °C
Lithium battery (2032)up to 5 years131 x 68 x 26 mm305 gIP65
2 years (int.)(ext.) (ext.)
0577 1716
NTC0 to+100 %RH-20 to+70 °C-20 to+70 °Ctd0.1 %RH0.1 °C
55000Readings2 sto24 h-20 to+70 °C-40 to+85 °CLithium battery (2032)up to 5 years
131 x 68 x 84 mm320 gIP652 years0577 1712
NTC0 to+100 %RH-20 to+70 °C-20 to+70 °Ctd0.1 %RH0.1 °C
55000Readings2 sto24 h-20 to+70 °C-40 to+85 °C
Lithium battery (2032)up to 5 years131 x 68 x 84 mm320 gIP65
2 years0577 1722Alarm output (relaycontact):1A/42V max. load
NTC0 to+100 %RH-10 to+50 °C0.1 %RH0.1 °C
20000Readings2 sto24 h-20 to+70 °C-40 to+85 °C
Lithium batteryup to 5 years131 x 68 x 84 mm320 gIP65
2 years0577 1713
NTC0 to+100 %RH-10 to+50 °C0.1 %RH0.1 °C
20000Readings2 sto24 h
-10 to+50 °C-40 to+85 °CLithium batteryup to 5 years131 x 72 x 68 mm
320 gIP652 years0577 1733 System±2 %RH(+2 to+98 %RH)(int.)±0.2 °C(-35 to+39.9 °C)±0.4 °C(+40 to+70 °C)(ext.) System±2 %RH(+2 to+98 %RH) System±2 %RH(+2 to+98 %RH)±0.4 °C(-10 to+50 °C)±0.5 °C(-20 to-10.1 °C)±0.5 °C(+50.1 to+70 °C)System±2 %RH(+2 to+98 %RH)±0.4 °C(-10 to+50 °C)±0.5 °C(-20 to-10.1 °C)
±0.5 °C(+50.1 to+70 °C)System±3 %RH(+2 to+98 %RH)±0.5 °C(-10 to+39.9 °C)±0.6 °C(+40 to+50 °C)System±2 %RH(+2 to+98 %RH)±0.4 °C(-10 to+50 °C) ±0.4 °C(-10 to+50 °C)±0.6 °C(-50 to-10.1 °C)±0.6 °C(+50.1 to+120 °C) ±0.2 °C(-34.9 to+39.9 °C)±0.4 °C(+40 to+120 °C)
±0.6 °C(-50 to-35 °C) Protection class Warranty Part no.Other features
±1 digit 0577 1715 Humidity Detailed information on all data loggers can be found in the brochure: “Measurement Solutions for Climate Applications in Industry”
|