23
Ordering suggestions, testo 177-T4
Set 1:Monitoring temperature distribution in refrigerators
Temperature data logger, 4-channel, with 4 probe inputs, wall-holder and calibration protocol0563 1774 Lock for wall holder for testo 175/177 data loggers0554 1755 Measurement tip with TC plug Type T0628 0023 Measurement tip with TC plug Type T0628 0023 Measurement tip with TC plug Type T0628 0023 Measurement tip with TC plug Type T0628 0023 testo 581 alarm signal output0554 1769 ComSoft 3 Set - Basic with USB interface0554 1767
ComSoft 3 Set - Basic with USB interface0554 1767
ComSoft 3 Set - Basic with USB interface0554 1767 >
Set 2:Monitoring temperature distribution in deep-freezers
Temperature
data logger, 4-channel, with 4 probe inputs, wall-holder and calibration protocol0563 1774 Lock for wall holder for testo 175/177 data loggers0554 1755 Immersion tip, flexible, TC Type K0602 5793 Immersion tip, flexible, TC Type K0602 5793 Immersion tip, flexible, TC Type K0602 5793 Immersion tip, flexible, TC Type K0602 5793 testo 581 alarm signal output0554 1769 >
Set 3:Monitoring temperature distribution in ovens, e.g. mufflekilns
Temperature data logger, 4-channel, with 4 probe inputs, wall-holder and calibration protocol0563 1774 Lock for wall holder for testo 175/177 data loggers0554 1755 Immersion tip, flexible, TC Type K0602 5792 Immersion tip, flexible, TC Type K0602 5792 Immersion tip, flexible, TC Type K0602 5792 Immersion tip, flexible, TC Type K0602 5792 testo 581 alarm signal output0554 1769 >
We recommend: We recommend:
4 x ISO calibration certificate/temperature, temp. data logger;calibration points -18°C; 0°C; +60°C0520 0151 4 x DKD calibration certificate/temperature, temp. datalogger; cal. points -20°C; 0°C; +60°C0520 0261 >
We recommend: We recommend:
4 x ISO calibration certificate/temperature , meas. instr.with air/immersion probe; calibration points 0°C; +300°C;+600°C 0520 0031 4 x DKD calibration certificate/temperature, Meas. instr.with air/immersion probe; cal. points 0°C; +100°C;+200°C0520 0221 >
Technical data Chann. external (var.)4Meas. range-200 to+400 °C-200 to+1000 °C-100 to+750 °C±0.5% of mv(+70.1 to+1000 °C)±1.5% of mv(-200 to-100.1 °C)
±0.3 °C(-100 to+70 °C)Accuracy±1 digitBattery lifeOper. temp.Storage temp.Battery type 2 sto24 hMeasuring rateMemoryAnalysis softwareResolution Probe type Type T (Cu-CuNi) Type K (NiCr-Ni)Type J (Fe-CuNi) Protection class Dimensions103 x 64 x 33 mm129 gWeightIP43 0.1 °C480000 to+70 °C-40 to+85 °CLithium battery5 years at meas. cycle 15 min (-10 to +50 °C)MS Windows 95b / 98 / ME / NT4-Sp4 / 2000 / XP
Temperature