Catalogue Reference Measurement Technology for Industry
www.testo.com
print switch display
Page / 93
TESTO - 253390, 208352
/ 93
See other catalogues for TESTO
Text version of the page

23

Ordering suggestions, testo 177-T4

Set 1:Monitoring temperature distribution in refrigerators

Temperature data logger, 4-channel, with 4 probe inputs, wall-holder and calibration protocol0563 1774 Lock for wall holder for testo 175/177 data loggers0554 1755 Measurement tip with TC plug Type T0628 0023 Measurement tip with TC plug Type T0628 0023 Measurement tip with TC plug Type T0628 0023 Measurement tip with TC plug Type T0628 0023 testo 581 alarm signal output0554 1769 ComSoft 3 Set - Basic with USB interface0554 1767 ComSoft 3 Set - Basic with USB interface0554 1767 ComSoft 3 Set - Basic with USB interface0554 1767

Set 2:Monitoring temperature distribution in deep-freezers

Temperature data logger, 4-channel, with 4 probe inputs, wall-holder and calibration protocol0563 1774 Lock for wall holder for testo 175/177 data loggers0554 1755 Immersion tip, flexible, TC Type K0602 5793 Immersion tip, flexible, TC Type K0602 5793 Immersion tip, flexible, TC Type K0602 5793 Immersion tip, flexible, TC Type K0602 5793 testo 581 alarm signal output0554 1769

Set 3:Monitoring temperature distribution in ovens, e.g. mufflekilns

Temperature data logger, 4-channel, with 4 probe inputs, wall-holder and calibration protocol0563 1774 Lock for wall holder for testo 175/177 data loggers0554 1755 Immersion tip, flexible, TC Type K0602 5792 Immersion tip, flexible, TC Type K0602 5792 Immersion tip, flexible, TC Type K0602 5792 Immersion tip, flexible, TC Type K0602 5792 testo 581 alarm signal output0554 1769

We recommend: We recommend:

4 x ISO calibration certificate/temperature, temp. data logger;calibration points -18°C; 0°C; +60°C0520 0151 4 x DKD calibration certificate/temperature, temp. datalogger; cal. points -20°C; 0°C; +60°C0520 0261

We recommend: We recommend:

4 x ISO calibration certificate/temperature , meas. instr.with air/immersion probe; calibration points 0°C; +300°C;+600°C 0520 0031 4 x DKD calibration certificate/temperature, Meas. instr.with air/immersion probe; cal. points 0°C; +100°C;+200°C0520 0221

Technical data Chann. external (var.)4Meas. range-200 to+400 °C-200 to+1000 °C-100 to+750 °C±0.5% of mv(+70.1 to+1000 °C)±1.5% of mv(-200 to-100.1 °C) ±0.3 °C(-100 to+70 °C)Accuracy±1 digitBattery lifeOper. temp.Storage temp.Battery type 2 sto24 hMeasuring rateMemoryAnalysis softwareResolution Probe type Type T (Cu-CuNi) Type K (NiCr-Ni)Type J (Fe-CuNi) Protection class Dimensions103 x 64 x 33 mm129 gWeightIP43 0.1 °C480000 to+70 °C-40 to+85 °CLithium battery5 years at meas. cycle 15 min (-10 to +50 °C)MS Windows 95b / 98 / ME / NT4-Sp4 / 2000 / XP

Temperature
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-93