| | | 47 | | |
| | | |
| | | Compact conductivity/°C measuring instrument - With range of probes | | |
| | | |
| | | testo 240 Measurement errors caused by high conductivities and deposits on the electrodes are avoided thanks to the 4 electrode engineering used. The salt level (NaCI) in an aqueous solution can be measured directly. | | |
| | | » Long life of measurement cell thanks to 4 electrode engineering »Extremely wide measurement ranges with only one measurement cell | | |
| | | 7t | | |
| | | |
| | | Conductivity and temperature measurement instrument in one | | |
| | | |
| | | |
| | | Versatile Set 1, Better value in set testo 240 conductivity and temperature measuring instrument, battery, 2 electrode clips, versatile conductivity measurement cell, case (plastic) Part no. 0563 2405 | | |
| | | |
| | | |
| | | Measuring salt level (NaCI) in pickling brine | | |
| | | testo 240 Part no. 0560 2404 | | |
| | | Precision Set 2, Better value in set testo 240 conductivity and temperature measuring instrument, battery, 2 electrode clips, precision conductivity measurement cell, case (plastic) Part no. 0563 2406 | | |
| | | |
| | | | | | | | | | | | Technical data | | | | Probe type | Conductivity measuring cell | NTC | Cale, parameter | | | | Meas. range | 0 to +2000 mS/cm | -50 to +150 °C | +1 to +200000 mg/l NaCI | | | | Accuracy ±1 digit | ±1% of mv (0 to +2000 mS/cm) | ±0.5% of mv ±1.2% of mv (+1 to (+100 to +150 °C) +200000 mg/l NaCI) ±0.2 °C (-25 to +74.9 °C) ±0.4 °C (remaining range) | | | | Resolution | | 0.1 °C | 0.1 mg/l NaCI | | | | Oper. temp. | 0 to +40 °C | Dimensions | 168x72x27 mm | | | | Storage temp. | -20 to +70 °C | Weight | 170 g | | | | Battery life | 60 h | Protection class | IP54 | | | | | | | | | | | |
| | | |
| | | | | | | | | | Accessories Ordering data | Part no. | | | | | 0554 2334 | | | | Set case (plastic) for measuring instrument, probes and accessories, user-friendly arrangement of measuring instrument and accessories | 0516 0230 | | | | ISO calibration certificate/analysis, for conductivity solutions; calibration point 1.413 mS/cm | 0520 0019 | | | | ISO calibration certificate/temperature, for air/immersion probes, calibration points -18°C; 0°C; +60°C | 0520 0001 | | | | ISO calibration certificate/analysis, at 3 conductivity values over the measuring range | 0520 0049 | | | | | | | | | |
| | | |
| | | Resolution max. 0.1 uS/cm; temperature compensation automatic; temperature coefficient: 0 to 5 %/°C linear; compensation in accordance with non-linear function of natural water to DIN 38404 from 0...+50°C; autom. measurement range switchover (conductivity); Auto OFF function; switch between °C/°F | | |
| | | |
| | | |
| | | Other features | | |
| | | Description | | Illustration | | Meas, range | | | Part no. | | |
| | | | |
| | | |
| | | |
| | | 4 electrode 0650 3023 engineering with built-in temperature Conn" Flxed cable sensor | | |
| | | +0.001 to +200 mS/cm 0 to +60 °C | | |
| | | Universal conductivity measuring cell, type 07 mS, highest accuracy up to 200 mS/cm, stainless steel | | |
| | | |
| | | |
| | | |
| | | | | |
| | | +0.001 to +300 mS/cm 0 to +60 °C | | | 0650 3024 Conn.: Fixed cable | | |
| | | Precision conductivity measuring cell, type 10 mS, long-term stable, highest accuracy up to 300 mS/cm, industrial graphite | | |
| | | |
| | | |
| | | |
| | | |
| | | Description Illustration Meas, range Accuracy t99 Part no. | | |
| | | |
| | | | | | | | | | Waterproof NTC ^^^^^^^M immersion/penetration probe | 115mm 50mm -50tO+150°C ±0.5% of mv (+100 to 10s 06131212 r 0 5 mm 0 4 mm +125 °C, short-term ±04 °C (remaining range) oonn.. nxeu Oduie +150 °C (2 minutes) | | | | Laboratory probe, glass-coated, resistant to corrosive substances, *s_|—=i— glass stem can be replaced | ?00mm 30 mm -50tO+150°C ±a5%ofmv(+100to 40 s 0613 7011 -l I ) Long-term meas. range +0.? °c (-P5 to +74.9 °a ._ Conn ■ Trcd cable 0 6 mm 05 mm +125 °C, short-term ±0.4 °C (remaining range) 10 oonn.. Mxea caoie +150 °C (2 minutes) S | | | | Stainless steel NTC food probe (IP65) with PUR cable | 125mm 15mm -50to+150°C ±o|%ofmv(+iooto 8s 06132211 0 4 mm 0 3 mm +125°C, short-term ±04 °C (remaining range) +150°C (2 minutes) | | | | Waterproof NTC surface probe for flat MOT* | 115mm 50mm -50tO+150°C ±0.5% of mv (+100 to 0613 1912 | | | | surfaces | 0 5 mm 0 6 mm +125 °C, short-term ±04 °C (remaining range) OOnn.: MXea caoie +150 °C (2 minutes) | | | | | | | | | |
| | | |
| | | | | * without protective glass | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |