| | | The truck data logger with 2 probe sockets and event logging | | |
| | | |
| | | testo 177-T3 testo 177-T3 documents 3 temperatures and an event simultaneously providing proof of an uninterrupted cooling chain during transport. For example, complete monitoring of ambient air, intake and outgoing temperature with simultaneous monitoring of the door or the compressor is possible when monitoring transport. The measuring rate of the event can be set completely independently of the measuring rate of the temperature channels. | | |
| | | 'Temperature logging of up to 48000 readings 1 Data is read out without interrupting the measurement series 1 Data analysis as table or graph, with Email function | | |
| | | Collect data on site, read out on your PC and analyse | | |
| | | |
| | | |
| | | testo 177-T3 Internal °C + 2 x external °C + event contact Temperature data logger, 3 channels, with Internal sensor, 2 probe sockets, door contact connection cable, wall holder and calibration protocol Part no. 0563 1773 | | |
| | | Temperature monitoring at different sites e.g. during transport, In warehouses, In containers etc. | | |
| | | |
| | | |
| | | |
| | | See page 38 for Accessories Ordering Data | | |
| | | |
| | | | | | | | | | | | Technical data | | | | Chann. Intern | 1 | Chann. externa | (var.) 2 | | | | Meas. range | -40 to +70 °C | Meas. range | -40 to+120 °C | | | | Accuracy ±1 digit | ±0.4 °C (-25 to +70 °C) ±0.8 °C(-40to -25.1 °C) | Accuracy ±1 digit | ±0.2 °C (-25 to+70 °C) ±0.4 °C (remaining range) | | | | Resolution | 0.1 °C | Resolution | 0.1 °C | | | | Memory | 48000 | Battery type | Lithium battery | | | | Oper. temp. | -40 to +70 °C | | 127 g | | | | Storage temp. | -40 to +85 °C | Dimensions | 103 x 64 x 33 mm | | | | External: Event logging e.g. door contact Battery life: 5 years with meas. rate of 15 min (-10 to +50°C) Measuring rate: 2 s to 24 h Software: Microsoft Windows 95b / 98 /ME / NT4-Sp4 / 2000 / XP | | | | | | | | | | | |
| | | Recommended Set: Temperature monitoring with printout on-site Temperature data logger, 3 channels, with internal sensor, 2 probe sockets, door contact 0563 1773 connection cable, wall holder and calibration protocol | | |
| | | |
| | | | | |
| | | |
| | | Stationary probe with aluminium sleeve, IP 65 | | |
| | | |
| | | Stationary probe with aluminium sleeve, IP 65 | | |
| | | |
| | | Fast testo 575 printer, ind. 1 roll of thermal paper and batteries | | |
| | | |
| | | ComSoft 3 Set - Basic with USB interface, Basic software with diagram and table function, incl. desk-top holders, PC connection cable | | |
| | | |
| | | |
| | | Description | | Illustration | | Meas. range Accuracy | | t99 | | Part no. | | |
| | | | |
| | | |
| | | -20 to +70 °C | | ±0.2 °C (-20 to +40 °C) 1 5 g ±0.4 °C (+40.1 to+70 °C) | | |
| | | 0628 7510 | | |
| | | |
| | | |
| | | Stub probe, IP 54 | | |
| | | |
| | | |
| | | ±o.2°C(oto+70°C) 190 s 0628 7503* | | |
| | | |
| | | ±0.5 °C (remaining range) | | |
| | | Stationary probe with aluminium sleeve, IP 65 , Refrigeration storeroom probe with aluminium sleeve, IP 54, with silicone insulated ribbon cable | | |
| | | Conn.: Fixed cable | | |
| | | |
| | | |
| | | 0 6 mm 40 mm | | |
| | | -40 to +90 °C (Short-term to +105 QC) | | 3.2°C(0 to +70 °C) 3.4 °C (-35 to 0 °C) 3.5 °C (remaining range) | | |
| | | 190 s 0628 0042 | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | -35 to +80 °C | | 0610 1725* Conn.: Fixed cable | | |
| | | 3.2°C(-25to+74.9°C) 5 s 3.4 °C (remaining range) | | |
| | | |
| | | Accurate imm./pen. probe, 6m cable, IP 67 | | |
| | | |
| | | |
| | | |
| | | 0628 0006* | | |
| | | Accurate immersion/penetration probe, cable: 1.5 m long, IP 67 | | |
| | | |
| | | |
| | | 3.2 °C (Oto +70 °C) | | 150 s 0628 7516* Conn.: Fixed cable | | |
| | | |
| | | J3 8X8H | | |
| | | Probe for surface measurement | | |
| | | |
| | | |
| | | |
| | | -50 to+150 °C | | ±0.5% of mv (+100 to +150 °C) ±0.2°C(-25 to+74.9 °C) ±0.4 °C (remaining range) | | 06132211* Conn.: Fixed cable | | |
| | | 8s | | |
| | | |
| | | Stainless steel NTC food probe (IP65) with PUR cable | | |
| | | |
| | | 4J^ | | |
| | | | |
| | | |
| | | |
| | | -25 to+150 °C | | ±0.5% of mv (+100 to +150 °C) ±0.2°C(-25 to +74.9 °C) ±0.4 °C (remaining range) | | 06132411* Conn.: Fixed cable | | |
| | | 7s | | |
| | | |
| | | Robust NTC food penetration probe with special handle, reinforced PUR cable | | |
| | | |
| | | |
| | | |
| | | |
| | | -50 to+140 °C | | ±0.5% of mv (+100 to +140 °C) ±0.2°C(-25 to +74.9 °C) ±0.4 °C (remaining range) | | 20s 06133211* Conn.: Plug-in cable | | |
| | | | Frozen food probe NTC, corkscrew design (Incl. plug-in wire) | | |
| | | |
| | | |
| | | |
| | | |
| | | -50 to+125 °C Long-term meas. range +125 °C, short-term +150 °C | | ±0.2 °C (-25 to +80 °C) 60 S ±0.4 °C (remaining range) | | |
| | | 0613 1712 Conn.: Fixed cable | | |
| | | Efficient, robust NTC air probe | | |
| | | |
| | | |
| | | |
| | | |
| | | D The specified seal class of the data loggers Is achieved with these probes. | | |
| | | * Probe tested to EN 12830 for suitability In the transport and storage sectors | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |