Differential pressure transmitter in cleanroom-conform panel design - testo 6383
4Pages

{{requestButtons}}

Catalog excerpts

Differential pressure transmitter in cleanroom-conform panel design - testo 6383 - 1

Differential pressure transmitter in cleanroom-conform panel design Measurement of differential pressure; optional: Automatic zero-point adjustment guarantees high, temperature-independent accuracy and long-term Low measurement range up to 10 Pa ensures highest precision at lowest pressures Flat housing allows flush surface integration in the cleanroom wall Display with multi-language operating menu and optical alarm display Ethernet, relay and analog outputs allow optimum integration into individual automation systems Self-monitoring of the transmitter and early warning function guarantee high system availably The P2A software for parameterization, adjustment and analysis saves time and costs in Scalability of ±50 percent of the measuring range final value and free scalability within the measuring The differential pressure transmitter testo 6383 was developed specially for monitoring low differential pressures in the measuring range from 10 Pa to 10 hPa. In cleanroom technology, the maintenance of positive pressure prevents the entry of contaminated air in critical zones. Thanks to an optional internal or external probe from the probe series 6610, the additional recording of humidity and temperature with one instrument is also possible. The testo 6383 is particularly outstanding thanks to the automatioc zero-point adjustment which ensures high accuracy and long-term stability. The integrated self-monitoring and early warning function also guarantees the operator high system • Monitoring positive and negative pressure in cleanrooms, operating theatres and isolation • Optional monitoring of humidity and temperature Configurable alarm management with adjustable response delay and alarm acknowledgement

Open the catalog to page 1
Differential pressure transmitter in cleanroom-conform panel design - testo 6383 - 2

Differential pressure transmitter in cleanroom-conform panel design Technical data Subject to change without notice. The determination of measurement uncertainty takes place according to GUM (Guide to the Expression of Uncertainty in Measurement): For the determination of measurement uncertainty, the accuracy of the measuring instrument (hysteresis, linearity, reproduceability), the uncertainty contribution of the test site as well as the uncertainty of the adjustment site (works calibration are taken into account. For this purpose, the value of k=2 of the extension factor, which is usual...

Open the catalog to page 2
Differential pressure transmitter in cleanroom-conform panel design - testo 6383 - 3

DataSheet-6383 05.12.2011 10:22 Seite 3 testo 6383 We measure it. Differential pressure transmitter in cleanroom-conform panel design Technical drawings 161 mm 396 mm 161 mm 3 mm 3 mm 78 mm 47 mm 47 mm 246 mm 175 mm 3 mm 396 mm 161 mm 24V + - CH1 + - CH2 + - CH3 + Status 01.08.2011 Connection plan - 20-30 V AC/DC + - 1 Subject to change without notice. 0981 8294/msp/A/08.2011 Page 3/4 0V

Open the catalog to page 3
Differential pressure transmitter in cleanroom-conform panel design - testo 6383 - 4

Differential pressure transmitter in cleanroom-conform panel design The following options can be specified for the testo 6383: BXX Analog display / supply CXX Display / menu language GXX opt. Analog output for humidity probe connection (probe series testo 6610) units G14 mbar/ min / max (water vapour partial G15 inch H20 / min/ max (water vapour partial G16 °Ctm (mixture dewpoint for H202) G17 °Ftm (mixture dewpoint for H202)—I only possible H01 4 relay outputs, limit value monitoring H02 4 relay outputs, channel 1 limit values and collective alarm DXX Integrated humidity probe Order code...

Open the catalog to page 4