Specifications
701 Module
Size (H x W x D): 4.9 x 5.7 x 2.0 inches
(12.4 x 14.5 x 5.1 cm)
Weight: 1.5 lbs (0.7 kg)
Material: Polystyrene
Enclosure: NEMA 4X, 6 (IP67)
Power: 9 to 14V DC (provided by 6700
Series Sampler)
Program Memory: Non-volatile, programmable flash;
can be updated via interrogator
port on 6700 Series Sampler using
a PC
Operating Temperature: 32° to 120°F (0° to 49°C)
Storage Temperature: 0° to 140°F (-18° to 60°C)
Ordering Information
Description Part Number
701 pH and Temperature Module with Stainless
Steel double junction combination pH probe.
Includes 25 ft. cable and instruction manual.
68-6700-052
Stainless Steel double-junction combination pH
probe with 25 ft. cable.
60-9004-126
Probe mounting hardware sold separately.
Teledyne Isco reserves the right to change specifications without notice.
2005 Teledyne Isco, Inc. • L-1130 • Rev 5’05
The 701 and other 700 Series Modules are
also compatible with the AvalancheĆĘ
transportable refrigerated sampler.
pH/Temperature Probe
Description: Submersible vertical or horizontal mounting probe with
combination type porous Teflon® liquid double junction
pH electrode to resist fouling and coating. Steam
sterilized glass hemi-bulb for long term stability. Built-in
amplifier and integral exposed temperature sensor.
Size: 6 inches (15.2 cm) long; 3/4 inch NPT (1.9 cm
diameter)
Body material: 316 Stainless Steel
pH range: 0 to 14 pH
pH accuracy: ±0.1 pH units from 0 to 11.9 pH. ±0.2 pH units from
12.0 to 14.0 pH
Temperature accuracy: ±1.8°F (±1°C)
Temperature range: 32° to 176°F (0° to 80°C). Continuous exposure
to temperatures above 140°F (60°C) may shorten
probe life.
Probe cable length: 25 ft. (7.6 m) standard length; longer lengths available.
|
|