Foxy R2 68-2130-006 High Flow Foxy R2 68-2130-007 Foxy R1 68-3870-010 Retriever 500 68-3880-001 Inlet Tubing and Flow Rates 1/8" OD (0.062" ID), 25 – 125 mL/min (up to 25 mL/min optional) 1/4" OD (0.125" ID), up to 1 L/min 1/16” OD (0.031" ID), up to 25 mL/min (25 – 125 mL/min optional) 1/16" OD (0.031" ID), up to 25 mL/min (25 – 125 mL/min optional) Maximum Tube Height 196 mm 180 mm 160 mm 180 mm Racks 2, with RFID 2, with RFID 1, no detection 17, with infrared rack sensor Maximum Tube Qty 288 12/13 mm tubes 144 12/13 mm tubes 102 12/13 mm tubes Max Fraction Volume Unlimited with funnel racks 50 mL with 29 mm centrifuge tubes Construction Materials: Racks Funnel Racks Diverter Valve Construction Drip Tray Drop Former Stainless steel and polypropylene ECTFE (Halar) or ETFE (Tefzel) funnels PEEK and FFKM (fluoroelastomer) Cast Aluminum Polypropylene PEEK Polypropylene n/a PCTFE (Kel-F*) Polypropylene Polypropylene and stainless steel ECTFE (Halar) or ETFE (Tefzel) Solvent Compatibility Aqueous and Organic Aqueous (Organic with optional valve) Test Tube Time Change 0.10 – 0.58 seconds (dependent on collection vessel tube advance speed) 0.35 seconds with 12/13 mm rack, within rack; 0.57 seconds between racks Memory Eight methods Current program Collection Modes: Time 00:00:01 – 99:59:59, 1 second intervals 5 – 999 sec; 0.1 – 99.9 min. in 0.1 min units; 1 – 999 min in 1 min units Drop 1 – 999 drops per fraction 1 – 999 drops per fraction; up to 7 per second Volume Up to 999 units Up to 999 units w/Tris Pump Peak Detection Slope, Threshold, four time windows, Combination of any of the above collection modes External System Control Front panel touch screen, Ethernet or RS-232 Front panel touchkey Inputs Pump counter, external peak, inject, tube advance: +3.3 to 5 VDC or contact closure, active low, 30 ms minimum, 5 VDC max. Analog peak voltage: 0 to 1.0 V nominal, –1.2 to + 1.2 V usuable, –5 to +5 V max. 18 volts, Max. Pump counter: CMOS or TTL logic ”0” for 7.7 ms min, Max rate 60 counts per sec. Tube change: Open collector TTL logic “0” or contact closure. Pause: Selectable; inactive, active TTL logic “1”, or active TTL logic “0” Outputs Pump pause/stop and event (tube change), 300 ms: open collector, active low, 15 VDC/100 mA maximum. Event marks: Open collector active for tube or rack change Automatic Shut-off Rack full, last tube, end of time window or external signal Last tube Security Valve (2-way) n/a Optional Diverter Valve (3-way) Included Optional Valve Pressure Rating 0 – 28 psi 0 – 28 psi Temperature Range 0 – 40 ΊC, 32 – 104 ΊF 0 – 40 ΊC, 32 – 104 ΊF Cold Room Compatible Yes Yes Dimension: WxHxD 12.25 x 14.9 x 21.0 in 31.1 x 37.8 x 53.3 cm 12.25 x 15.5 x 21.0 in 31.1 x 39.4 x 53.3 cm 12.25 x 14.0 x 13.0 in 31.1 x 35.5 x 33.0 cm 8.3 x 7.09 x 11.4 in 21.0 x 18.0 x 29.0 cm Weight 10.3 kg (22.8 lbs) 10.4 kg (22.9 lbs) 7.1 kg (15.6 lbs) 3.0 kg (6.61 lbs) Power Requirements 100 – 240 VAC, 50-60 Hz, 1 ampere max. Includes one IEC power cord supplied for regional AC power (100, 117, 234 VAC) 14 VAC, 50/60 Hz, 150 mA max. from Teledyne Isco 15W wall transformer for regional AC power (100, 117, 234 VAC) Certification CE, CSA CE Fraction Collector Selection Guide * A registered trademark of 3M To order contact Teledyne Isco or your local representative 4700 Superior Street • Lincoln, NE 68504 USA Toll free: (800) 228-4373 (USA & Canada) • Phone: (402) 464-0231 Fax: (402) 465-3022 • iscoinfo@teledyne.com Brochure L-5146 • Printed in the USA • © 2009, all rights reserved • 10/09

pageCatalog pdf di En 2012-05-22-31