HPM-760s Installation
HPM-760s Installation
Figure below shows the Hastings piezo vacuum transducer. A standard 1/8" NPT male stem and evacuation port is provided for system connection. VCR and KF stem terminations are also available
Figure below shows the Hastings piezo vacuum transducer. A standard 1/8" NPT male stem and evacuation port is provided for system connection. VCR and KF stem terminations are also available
When installing industrial transducers with threaded stem, apply an approved vacuum sealant to the stem threads of the transducer. Hand thread
When installing transducers with threaded stem, apply an approved vacuum sealant to the stem threads of the transducer. Hand thread transducer into vacuum system, until joint is finger tight. Tighten transducer module completely using a wrench on the hexagonal portion of the stem.
Do not grip instrument case to tighten; this will result in permanent damage to transducer ^ assembly. When the 760s is purchased indepen- L dently of the power supplyjdisplay, a connector supplier is provided so that the transducer can be connected as detailed in the figure.
TRANSDUCER PIN-OUT
PIN 1................SIGNAL OUTPUT (COM)
PIN 2................SIGNAL OUTPUT (POS)
PIN 3................15-30 VDC INPUT (COM)
PIN 4................15-30 VDC INPUT (POS)
Manual may be obtained at: http://www.teledyne-hi.com
SPAN
Adjustment
ZERO Adjustment
Electronics Module
Stem
Termination
1/8" NPT
(shown)
VCR and
KF also available
SPAN
Adjustment
ZERO
Adjustment
Electronics Module
Stem
Termination
1/8" NPT
(shown)
VCR and
KF also available
transducer into vacuum system, until joint is finger tight. Tighten transducer module completely using a wrench on the hexagonal portion of the stem.
Do not grip instrument case to tighten; this will result in permanent damage to transducer assembly. When the 760s is purchased indepen­dently of the power supplyjdisplay, a connector is provided so that the transducer can be connected as detailed in the figure.
TRANSDUCER PIN-OUT
PIN I................SIGNAL OUTPUT (COM)
PIN 2................SIGNAL OUTPUT (POS)
PIN 3................15-30 VDC INPUT (COM)
PIN 4................15-30 VDC INPUT (POS)
Manual may be obtained at: http://www.teledyne-hi.com
N
Connector Vin I
Pin 1
Control # 166_122003B
Control # 166_122003B
HPM-760s Installation
HPM-760s Installation
Figure below shows the Hastings piezo vacuum transducer. A standard 1/8" NPT male stem and evacuation port is provided for system connection. VCR and KF stem terminations are also available
Figure below shows the Hastings piezo vacuum transducer. A standard 1/8" NPT male stem and evacuation port is provided for system connection. VCR and KF stem terminations are also available
When installing transducers with threaded stem, apply an approved vacuum sealant to the stem threads of the transducer. Hand thread
When installing transducers with threaded stem, apply an approved vacuum sealant to the stem threads of the transducer. Hand thread transducer into vacuum system, until joint is finger tight. Tighten transducer module completely using a wrench on the hexagonal portion of the stem.
Do not grip instrument case to tighten; this will result in permanent damage to transducer assembly. When the 760s is purchased indepen­dently of the power supplyjdisplay, a connector is provided so that the transducer can be connected as detailed in the figure.
\Connector
PIN 1................SIGNAL OUTPUT (COM) Pin 1
PIN 2................SIGNAL OUTPUT (POS)
PIN 3................15-30 VDC INPUT (COM)
PIN 4................15-30 VDC INPUT (POS)
SPAN
Adjustment
ZERO
Adjustment
Electronics Module
Stem
Termination
1/8" NPT
(shown)
VCR and
KF also available
SPAN
Adjustment
ZERO
Adjustment
Electronics Module
Stem
Termination
1/8" NPT
(shown)
VCR and
KF also available
transducer into vacuum system, until joint is finger tight. Tighten transducer module completely using a wrench on the hexagonal portion of the stem.
Do not grip instrument case to tighten; this will result in permanent damage to transducer assembly. When the 760s is purchased indepen­dently of the power supplyjdisplay, a connector is provided so that the transducer can be connected as detailed in the figure.
TRANSDUCER PIN-OUT
PIN 1................SIGNAL OUTPUT (COM)
PIN 2................SIGNAL OUTPUT (POS)
PIN 3................15-30 VDC INPUT (COM)
PIN 4................15-30 VDC INPUT (POS)
Manual may be obtained at: http://www.teledyne-hi.com
Pin 1
Control # 166_122003B
Control # 166_122003B