photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors - #1

/ 15


catalogue search
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 01
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 02
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 03
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 04
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 05
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 06
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 07
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 08
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 09
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 10
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 11
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 12
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 13
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 14
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors
P. 15
Pages:
photoelectric sensors_Model_SM 3000-6000-7000-8000 - Telco Sensors


See other catalogues for Telco Sensors

Text version of the page

SpaceMaster™ Series SM 3000

Description

Operation mode and max sensing range: Thru beam : 1-12 m Cable or plug connection Sensitivity adjustment via control input Wide variety of housings Power and output indicator High tolerance to hostile environments 10 – 30 V dc supply voltage 3 wire, NPN or PNP transistor output

The 3000 series consists of a low cost self-contained transmitter SMT,and a receiver SMR, which are to be used in thru beam mode. The complete series is available in a wide range of housings with either cable or plug connection.The SMR is supplied with a 10-30 V dc supply voltage with a 3 wire, NPNor PNP transistor output with a choice between light or dark function.The control input in the SMT may be used for either disabling or enablingthe transmitting power temporarily for test purpose, multiplexing applications or as a gradual regulation of the transmitting power level.Both the transmitter and receiver are protected against reverse polarity of power supplies, control input and output signals. The output is also protected against short circuit and inductive loads. Technical Data

SMT 3000CSMT 3012CSMR 3X06SMR 3X12 Supply voltage 10– 30 V dc Voltage ripple15% Reverse polarity protectedYes Short circuit protected–Yes Power consumptionMax. 30 mAMax. 8 mA Maximum output load–100 mA Maximum residual voltage–2,5 V Maximum operation frequency–> 125 Hz Response time t
ON / t
OFF –

Environmental Data

Vibration10– 55 Hz, 0,5 mm Shock30 g Light immunity, @ 5°incidence–35 000 lux12 000 lux Temperature, operation –20 to +50 C Temperature, storage –40 to +80 C Sealing classIP 67Approvals a