temperature datalogger - Tecpel Co., Ltd. - #1

/ 1


catalogue search
temperature datalogger - Tecpel  Co., Ltd.
P. 01
Page:
temperature datalogger - Tecpel  Co., Ltd.


See other catalogues for Tecpel Co., Ltd.

Text version of the page
Digital Thermometers Data logger
Single Input + Data recorder
□ -200°C~1370°C(-328°F~2498°F)
□ Data Logging capacity 16,000 records
□ 4 Digit LCD, Triple display
□ Timer display
□ Recording interval setup
□ Reading hold °C or °F annunciators
□ Single K-type thermocouple input
□ MAX. MIN. function
□ Auto power off
□ Hold, AREL functions
□ Automatic low battery indication
□ High resolution 0.1 °C, 0.1 T
□ RS-232 Computer interface
□ Real time Display
Measurement range -200°C to 1370"C(-328'F to 2498° F)
Accuracy
-200°Cto1370°C
± (0.5% rdg+1°C) typical
-328°F to 2498T
± (0.5% rdg +1°F) typical
Temperature scale
Celsius or Fahrenheit user-selectable
Resolution
O.fCor 0.1'F(200°C~1370,CI1"C)
Sensor
K-type bead Thermocouple probe
Sampling rate
2.5 times/per second
Input protection
60V DC or 24V rms AC Maximum
General
Power requirement
9V Battery x1
Dimensions
184x64x30mm (7.2"x2.5"x1.2")
Weight
7,4 Oz (21 Og)
Accessories
1 x TPK-01 probe, 9V battery, Deluxe carrying case,
owners manual, RS-232 cable and software program
Dual Input + Data recorder
□ -200°C~1370°C(-328T~2498°F)
□ Data Logging capacity 16,000 records
□ 4 Digit LCD , Triple display
□ Timer display button
□ Recording interval set up
□ Reading hold °C or °F annunciators
□ Dual K-type thermocouple inputs
□ MAX. MIN. function
□ Auto power off
□ Hold functions
□ Automatic low battery indication
□ High resolution 0.1 °C, 0.1 °F
□ RS-232 Computer interface
□ Real time Display
Measurement range -200°C to 1370°C(-328°F to 2498'F)
Accuracy
-200°C to1370°C
± (0.5% rdg +1°C) typical
-328°Fto 2498T
±(0.5% rdg+1°F) typical
Temperature scale
Celsius or Fahrenheit user-selectable
Resolution
0.1 "C or0.rT(200°C~1370°C, fC)
Sensor
K-type bead Thermocouple probe
Sampling rate
2.5 times/per second
Input protection
60V DC or 24V rms AC Maximum
General
Power requirement
9V Battery x1
Dimensions
184x64x30mm (7.2"x2.5"x1.2")
Weight
7.4 Oz (21 Og)
Accessories
2 x TPK-01 probes, 9V battery, Deluxe carrying case,
owners manual, RS-232 cable and software program.
Measurement range | -200°C-1370°C(-328°F~2498°F)
Accuracy
-200°C to 200°C
±(0.2% rdg +1°C)
200°C to 400°C
±(0.5%rdg+1°C)
400°Cto1370°C
± (0.2% rdg +1"C)
-328T to 200°F
± (0.5% rdg +1T)
200°Fto 200°F
± (0.2% rdg +1"F)
200°Fto2498°F
±(0.3% rdg +1°F)
Temperature scale
Celsius or Fahrenheit user-selectable
Resolution
0.1'C or0.1°F(200°C~1370°C, 1"C)
Sensor
K-type bead Thermocouple probe
Sampling rate
3 seconds per testing circle
Input protection
60V DC or 24V rms AC Maximum
General specifications
Power requirement
9V Battery x1
Dimensions
184x64x30mm (7.2"x2.5"x1.2")
Weight
7.4 Oz (21 Og)
Accessories
RS-232 cable and software for WINDOWS, Deluxe
carrying case, owners manual, TPK-01 bead probe x 2 pes
Option Accessory
Adaptor (AC 120V or 220V input, DC 9V output)
Quad Input + Data recorder
□ -200°C~ 1370°C (-328 °F ~ 3498 °F)
□ Data Logging capacity 16,000 records per channel
□ 4 Digit LCD display
□ Timer function
□ Reading hold °C or °F annunicators
□ 4 K-type thermocouple inputs
□ MAX. MIN. function
□ Auto power off
□ HOLD function
□ Automatic low battery indication
□ Overrange indication
□ Real time Display
DTM-319
Real time display (DTM-317,318,319)

pageCatalog pdf di En 2012-02-07-13