| | | and Humidity Meter | | |
| | | Temper | | |
| | | |
| | | Dual Input | | |
| | | |
| | | | | | | | | | Measurement range | T1:-20'C~60'C (-4T-140T) | | | | | T2: K-type: -2O0'C~1370'C (-328°F~2498*F) | | | | Humidity | 0~100%RH, Accuracy ±2.5%RH | | | | Accuracy | | | | -20°C~+«)°C | T1:±0.7*C | | | | -4T-140T | T1:±1.4'F | | | | -200°C~1370°C | T2:±(0.3%rdg +1 "C) typical | | | | -328°F~2498°F | T2:± (0.3% rdg+2'F) typical | | | | Temperature scale | Celsius or fahrenheit user-selectable | | | | Resolution | Humidity: 0.1% RH; Temp. T1:0.1'C, 0.1°F T2: -200'C~200'C, 0.1'C; 20O'C~1370'C,1'C. | | | | Sensor | K-type Thermocouple | | | | Response time(T1) | Humidity: 75 sec. in slowly moving air | | | | Temperature | 40 sec. in slowly moving air | | | | Input protection | 60V DC or 24V rms AC maximum | | | | General | | | | Power requirement | 9V Battery x1 | | | | Dimensions | Meter: 186x64x30mm (10.8"x2.5"x1.2") Probe: 190x15mm (7.5"x0.6") Weight: 11.2Oz(320g) | | | | Accessories | 1 x TPK-01 probe, 9V battery, Deluxe carrying case, owners manual | | | | | | | | | |
| | | □ Temp: -20°C ~ 60°C(-4°F~140'F) K-type: -200°C~1370°C(-328°F~2498T) Humidity: 0-100%RH □ 4 Digit, triple display □ K-type termocouple Reading hold, °C or °F annunciators MAX. MIN. function Auto power off AREL function Automatic low battery indication RS-232 computer interface RS-232 cable and software for Windows (Options) | | |
| | | |
| | | DTM-321 | | |
| | | |
| | | |
| | | Real time display | | |
| | | |
| | | | | | | | | | Model | DTM 321 DTM 322 | | | | A REL function | V N/A | | | | Data logging | N/A V | | | | RS-232 cable & software | option V | | | | | | | | | |
| | | |
| | | Dual Input +Data Recorderj | | |
| | | |
| | | | | | | | | | Measurement range | T1:-20°C~60'C (-4T-140T) | | | | | T2: K-type: -200"C~1370'C (-328'F~2498'F) | | | | Humidity | 0~100%RH, Accuracy ±2.5%RH | | | | Accuracy | | | | -20°C~+60°C | T1:±0.7'C | | | | -4°F~140°F | T1:±1.4T | | | | -200°C~1370°C | T2: ± (0.3% rdg +1 °C) typical | | | | -328°F~2498°F | T2:± (0.3% rdg+2'F) typical | | | | Temperature scale | Celsius or Fahrenheit user-selectable | | | | Resolution | Humidity: 0.1% RH; Temp. T1:0.1'C, 0.1'F T2: -200'C~200"C, 0.1'C; 200'C~1370'C,1'C. | | | | Sensor | K-type thermocouple | | | | Response time(T1) | Humidity: 75 sec. in slowly moving air | | | | Temperature | 40 sec. in slowly moving air | | | | Input protection | 60V DC or 24V rms AC maximum | | | | General | | | | Power requirement | 9V Battery x1 | | | | Dimensions | Meter: 186x64x30mm (10.8"x2.5"x1.2") Probe: 190x15mm (7.5"x0.6") Weight: 11.2 Oz(320g) | | | | Accessories | 1 x TPK-01 probe, 9V battery, Deluxe carrying case, owners manual, RS-232 cable & software for Windows | | | | | | | | | |
| | | □ Temp:-20"C~60'C(-4T~140'F) K-type: -200°C~1370°C(-328°F~2498'F) Humidity: 0-100%RH Data Logging capacity 16,000 records 4 Digit, triple display K-type termocouple Reading hold, °C or °F annunciators MAX. MIN. function Auto power off Time function Automatic low battery indication RS-232 computer interface RS-232 cable and software for windows | | |
| | | |
| | | DTM-322 | | |
| | | |
| | | |
| | | Real time display | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | |