| | | Differential Probes J converts the high voltage differential input signal to a low voltage ground referenced signal for display on any Oscilloscope. □ 3 Range Attenuator. J 1000V Input CAT III. □ Low battery indication, Auto power off. J Meet CE.IEC 1010, EN 61010. UL 3111. | | |
| | | |
| | | | | | | | | | Band width (-3dB, son load) | DC-25MHz.(x20:DC-15MHz) | | | | Accuracy | * 2% at 20-30"C 70% RH after 20 minutes warm up. | | | | Attenuation | x 20, x 50, x 200 (Into 1 MO scope); x 40. x 10, x 400 (Into 50Q load) | | | | Maximum operation Voltage ( DC * peak AC ) | s±140Vatx20 s±350Vatx50 s ± 1300V at x 200 | | | | Maximum input Differential Voltage | 1300V (DC + peak AC) or 1000V RMS | | | | Maximum input Voltage to Ground | 1000V (DC + peak AC) or 600V RMS | | | | | | | | | | | | | | | | Common Mode Rejection Ratio {CMRR) | 60Hz : >10,000 :1 100Hz:>1,000:1 1MHz:> 300:1 Noise: s 2 mV rms (Into 50O load) | | | | Input Impedance | 2MO, 2.3 PF between inputs and ground. 4MO. 1.2 PF between inputs. | | | | Power requirement | One internal 9V alkaline battery or external 6V-9 | | | | Dimensions | 180x50x30mm(7.1,x1.9Mr) | | | | Weight | 250g(9Oz) | | | | | | | | | |
| | | |
| | | High Voltage Probe J Max.Voltage:15KVDC. _l Bandwidth:DC~50MHz. _l Division Ratio:X10O0 _l Signal/Noise :>60dB(1 KHz) □ Connect with PL-10, HVP-15HF can be used for DMM | | |
| | | | | | | | | | Max. Working Voltage | DC: 0- 15KV DC, AC : Pulse s30KV p-p AC: Since WaveslOKV rms | | | | SignaWoise | *60dB (1KHz). ¿50 dB(1MHz) | | | | Bandwidth | DC -50MHz (-3dB) | | | | Division Ration | 1:1000 | | | | Rise Time | *7nS | | | | Input Resistance | 100MO±0.5% | | | | Input Capacitance | 3.0PF±0.5PF | | | | Compensation Coefficient | s200PPM/"C | | | | DC accuracy s 0.7% | | | | Weidht/Dimension 250g (340mmLx75o) | | | | | | | | | |
| | | |
| | | HVP-15HF (1000:1 . 50MHz, low noise HV probe) | | |
| | | |
| | | |
| | | PL-10 | | |
| | | |
| | | High Voltage Meter J DC 40KV CAT II Pollution 2 J 600MQ Impedance J 25KV ± 2%, 40KV ± 3% J T.C. 200 ppm/oC | | |
| | | J Positive Polanty only. J Resolution 1KV □ Need not power. J CE, TUV GS. UL, CUL, IEC1010 | | |
| | | |
| | | |
| | | | | | | | | | SPECIFICATIONS Input impedance Maximum operation voltage | (20±5'C, RH<80%) 600MO. | | | | 40KV DC, CAT II, Pollution 2 | | | | Polarity | Positive on:y | | | | Display | Analog indicate | | | | Accuracy | Factory calibrater 25KV ± 2% | | | | | FULLscale40KV±3% | | | | Temperature Coefficient | s200ppm/*C | | | | Maximum loading Current | s70j>A | | | | | | | | | | | | | | | | Maximum loading power | s 3 watt | | | | Voltage Range | 40KV/1 Range | | | | Voltage resolution | 1KV | | | | Power source | Need no: power | | | | Operating temperature | 0"C~ + 50"C | | | | Storage temperature | •20'C- + 70'C | | | | Ground lead length | 90cm(35-) | | | | Dimensions: | 420 mmL x 80s | | | | Weight | 360g (12.60z) | | | | | | | | | |
| | | HVP-40M | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | |