|
|
See other catalogues for Tecpel Co., Ltd.
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | Heavy Duty Clamp-on Meters | | | | | | | | | | | | | | | | | | | SPECIFICATIONS: All at 23±5°C, <75% R.H. | 2600 | 2606 | | | | DC VOLTAGE | Ranges: | 1000V | 400mV, 4V, 40V, 400V, 1000V | | | | Basic Accurancy: | ±(0.5%rdg+1d) | +(0.5%rdg+1d) | | | | Resolution: | 1V | 100nV | | | | Input Impedance: | 10MO | 10MJ2 | | | | OL Protection: | 1000VDC/750V RMS | 1000VDC/750V RMS | | | | AC VOLTAGE | Ranges: | 750V | 400mV, 4V, 40V, 400V, 750V | | | | Basic Accurancy: | ±(1.2%rdg+4d) | ±(1.5%rdg+4d) | | | | Imput Impedance: | 4.5MQ | 10MĪĪ | | | | Resolution: | 1V | 1mV | | | | OL Protection: | 1000VDC/750V RMS | 1000VDC/750V RMS | | | | Conversion Type: | Average sensing RMS indicating | True RMS | | | | AC CURRENT | Ranges: | 200A.1000A | 400A,1000A | | | | Basic Accurancy: at the center of CT | ±(1.5%rdg+5d) | ±(1.5%rdg+5d) | | | | Position Error: | ±1.0% | ±1.0% | | | | Resolution: | 100mA | 100mA | | | | OL Protection: with 60 seconds | 1200A | 1200A | | | | Conversion Type: | Average sensing RMS indicating | True RMS | | | | DC CURRENT | Ranges: | N/A | 400A, 1000A | | | | Basic Accurancy: at the center of CT | ±(1,5%rdg+5d) | | | | Position Error: | ±1.0% | | | | Resolution: | 100mA | | | | OL Protection: | 1200A | | | | RESISTANCE | Ranges: | 200, 20K, 20M, 2000M£i | 400, 4K, 40K, 400K, 4M, 40MU | | | | Basic Accurancy: | ±(1.0%rdg+3d) | +(1.0%rdg+2d) | | | | Resolution: | 100m£! | 100mD | | | | OL Protection: | 500VDC / AC RMS | 500VDC / AC RMS | | | | CONTINUITY | Audible Indication: | 200S2 | 400J2 | | | | Threshold: | <75Q | <40< > | | | | Respone Time: | 500msec | 100msec | | | | Open Circuit Voltage/Test Current: | 3.0V | 0.4VDC | | | | OL Protection: | 500VDC / AC RMS | 500VDC /AC RMS | | | | DIODE | Test Current: | N/A | 0.6mA | | | | Open Circuit Voltage: | 3.2V | | | | Accuracy: | ±(1.5%rdg+2d) | | | | OL Protection: | 500VDC / AC RMS | | | | FREQUENCY | Ranges: | N/A | 100, 1K, 10K, 100K. 400KHz | | | | Accuracy: | ±(0.5%rdg+3d) | | | | Resolution: | 0.01Hz | | | | Sensitivity: | 2V RMS | | | | OL Protection: | 500VDC / AC RMS | | | | CAPACITANCE | Ranges: | N/A | 4nF, 40nF, 400nF, 4uF, 40fiF | | | | Accuracy: | ±(1.0%rdg+4d) | | | | Resolution: | 0.001uF | | | | OL Protection: | 500VDC / AC RMS | | | | GENERAL: | | | | Display: | 2000 counts | 4000 counts | | | | Analog Bar Graph: | N/A | 42 segments, 20 / sec | | | | Overrange Indication: | OL | MSD blinks | | | | Low Battery Indication: | * | * | | | | Display Update Rate: | 2.5 / sec | 2 / sec | | | | Operating Temperature: 0 to 50'C, <70%R.H. | * | * | | | | Storage Temperature: -20 to 60"C, <80%R.H. | * | * | | | | Power: 9V battery, NEDA 1604, JIS 006P, IEC 6F22 | * | * | | | | Auto Power Off: | N/A | 30 minutes | | | | Battery Life: in hours(Alkaline) | 500 | 500 | | | | Jaw Opening Capability: 57mm conductor, 70x18mm busbar | * | * | | | | Dimensions(HxWxD): 10.8x3.6x1.7 inches,275.4x90x43mm | * | * | | | | Weight: in ounces | 17.0 | 18.3 | | | | Accessories: safety test leads, carrying case and manual | | * | | | | Safty: Design to meet IEC 1010-1, UL1244/UL3111, CE | * | * | | | | Auxiliary Feature: DATA HOLD | * | * | | | | MAX HOLD | * | N/A | | | | RANGE HOLD | N/A | * | | | | PEAK HOLD | * | | | | MAX/MIN HOLD | * | | | | ZERO(Relative) | * | | | | | | | | | | | | | | | | | | | 4F-1, No. 225, HePing East Rd. Sec. 3, Taipei 11056, Taiwan, R.O.C. Tel: (02) 2737-5866 Fax: 886-2-2737-3343 E-mail: sales@tecpel.com http://www.tecpel.com | | | | | | TECPEL | | | | | | CO., LTD. | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|