Catalogue XS, SL-heater
www.taketsuna.com
print switch display
Page / 1
Contact the
Manufacturer
Where to buy
this product ?
Taketsuna - 157483, 208136, 90981, 93487
/ 1
See other catalogues for Taketsuna
Text version of the page
1
XS-2 series
XS-3 series
XS-4 serie
Fixation stand
With nipple RI1/2
With A,B-sensor [K]
Material : Main touching gas department SUS
Material : Main touching gas department SUS
A-sensor (For detecting the outlet hot-air temp.) [K] Incorporated (Compensating wire 5m)
B-sensor(For hot-start and overheat prevention) [K] Incorporated (Compensating wire 5m)
Common specification % Standard Rating - Continuation ©Ambient temp. -10° C - +70° C 0 Ambient humidity Less than 90% R.H. (Non-condensation) % Place where is not exposed to wind and rain. (Indoor specification) • Please designate the model and type at the time of the order.
Material : Main touching gas department SUS
Permission pressure : Please use less thna the pressure that was entered. A little leakage may occur from screw department. But, it has no problem to performance.
Model
XS-2A
XS-2B
XS-2C
XS-3A
XS-3B
XS-3C
XS-4A
XS-4B
XS-4C
Type
1200-1.5
1200-2.4
1200-3.8
3200-3
3200-5
3200-10
3200-4
3200-8
3200-12
Psu 50/60Hz
Single-phase 200V
3-phase 200V
3-phase 200V
Heater capacity
1.5kW
2.4kW 3.8kW
3kW 5kW 10kW
4kW 8kW 12kW
Continuation use max. hot-air temp.
3000
350t
450t
450TJ
Temp. of supply air
Less than 140° C
Less than 300° C
Less than 230 C
Permission pressure
58.84kPa
58.84kPa
39.2kPa
Max usable gas capacity
3mVmin
6mVmin
6mVmin
Bore of the inlet
p 50 (OP : Rl/2 Nipple)
p 50 Inside : RpV2 Socket
065
Bore of the outlet
p50 (OP : Rl/2 Nipple)
<p50 Inside : RpV2 Socket
065
Kind of the power cord * Size * Length
Heatproof electric wire * 2mm2 * 0.5m
Without the power cord. (M5 Terminal)
Without the power cord. (M5 Terminal)
Net weight
1.6kg 1.9kg 2.5kg
6.5kg 8.5kg
9.0kg
7.6kg 8.2kg
9.9kg
Maching auto-temp. controller
TRC201
TR30A
TR50A
TRC303
TRC503
Open price
¥49,700 ¥53.300 ¥55,200
¥90,000 ¥93,800
¥97,400
¥147,000 ¥150,700
¥154,400
Option
Fixation stand (With band : For XS-2A - 3A)
Both sides nipple processing to the outlet and inlet (R1 Nipple)
With A-sensor (For detecting the outlet hot-air temp.) and B-sensor(For hot-start and overheat prevention) Different voltage specification : Single-220V (Only XS-2C)
With A-sensor for detecting the outlet hot-air temp. [K] K600A (Sheath diameter p 3 .2 * Sheath length 200mm * Compensating wire 5m with PTVg C.F.) Different voltage specification : 3-phase 220V 3-phase 380V, 400V, 440V (Only XS-3B and 3C)
Different voltage specification : 3-phase 220V, 380V 3-phase 440V (Only XS-4B and 4C)
Control number (This is the control number for inside the company.)
TIS001S000 TIS001S000 TIS001S000
TISOO l SOOO TISOO1SOOO TISOO1SOOO
TISOO 1 SOOO TISOO 1 SOOO TISOO 1 SOOO
ttention on us
Adiabatic cover DK89
Fixation metal professional fittings SP-030
Common specification
O Standard Rating - Continuation
0 Ambient temp. -10° C - +70° C
0 Ambient humidity Less than 90% R.H. (Non-condensation)
0 Place where is not exposed to wind and rain. (Indoor specification)
• Please designate the model and type at the time of the order.
• Heater snap (smelts) several minutes later by the airless heating if electricity flowed to the heater without supplying air. This time, it may ignite in the case that the combustible was in surroundings because the heater case is a high temp.. Please take the inter-lock circuit with the ventilation resource without
fail.
(We can not guarantee the snapping of a wire by the melting of the heater.)
• Please use the clean air that moisture, oil and dust etc. are not mixing to the ventilation resource.
Insulation of the heater falls off and the life of the heater becomes short if moisture, oil and dust etc. mix to the heater inside. The dust that was heated by the heat of the heater changes into the spark and jump out from the hot-air outlet if dust mixes to the inside. It is very dangerous.
Material : Heateer case SUS, Electrode flange SS (Metallic silver)
Permission pressure : Please use less thna the pressure that was entered. A little leakage may occur from screw department. But, it has no problem to performance.
A-sensor K600A (OP)
MODEUSL-3
MODELSL-6
M0DEUSL-3T
M0DELSL-6T
Model
SL-3
SL-4
SL-6
SL-3T
SL-4T
SL-6T
Type
3200-4
3200-4
3200-5
3200-7
3200-5
3200-7
Power supply 50/60Hz
3-phase 200V
3-phase 200V
Heater capacity
Attachment attitude at usually operation Attachment attitude at hot-start operation
When using more than 400' C (XS-2 with A, B-sensor , and XS-4)
5kW
7kW
4kW
4kW
5kW
7kW
Continuation use max. hot-air temp.
soot:
Less than 70° C
soot
Less than 70 C
Temp. of supply air
^Permission pressure
Impossible
98kPa
490kPa
Max usable gas capacity
2.5nf/min
2.5mVmin
R1V2 Socket
R11/2 Socket
Bore of the inlet
R1V2 Nipple
Bore of the outlet
R11/2 Nipple
2PNCT 4-core * 3.5mm2 * 3m
Heatproof electric wire * 2mm2 * 1m
±20'
Heatproof electric wire * 3.5mm2 * 1m
Kind of the power cord * Size * Length
2PNCT 4-core * 2mm2 * 3m
Net weight
5.0kg
6.2kg
7.5kg
5.5kg
6.7kg
8.0kg
Maching auto-temp. controller
TR30A
TR30A
Impossible
Open price
¥101,100
¥104,800
¥1 10,300
¥1 19,500
¥123,200
¥128,700
Wet felt insulating material (Heatproof 1200° C Refer to the option catalog), Professional hose nipple for p 38 hose connection (Material SS) 32A Plug (Material SS), PTV8 Hose nipple for detecting pressure (Material BsBM), PTV8 plug (Material SUS)
• With A-sensor for detecting the outlet hot-air temp. [K] K600A (Sheath diameter p3 .2 * Sheath length 200mm * Compensating wire 5m with PT1^ C.F.)
• Fixation metal fittings SP-030 (2pcs. lset) „
• Adiabatic cover DK89 Outside diameter pp 1 39 * Length 100mm Heatproof 1300 C (Material : Silica alumina)
• Different voltage specification : 3-phase 220V 3-phase 380V, "400V, 440V (Only SL-4, 6, 4T, and 6T)
Impossible
Accessories
This can use with every attachment attitude in the case that outlet hot-air temp. is used less than 400' C. • Please pay attention so as not to flow backward heat when the supply of air is stopped and hot-start operation even in either attachment attitude. Overheat prevention occurs or the power supply interconnection terminal, inside wiring, and terminal etc. may damage in the case that heat flowed backward. So, please suspend the supply of air after cooling operation is conducted without fail.
Option
Control number (This is the control number for inside the company.)
TISOO 1 SOOO
TISOO 1 SOOO
TISOO 1 SOOO
TISOO 1 SOOO
TISOO 1 SOOO
TISOO 1 SOOO