| | | 4/5 | | |
| | | RELIABILITY DATA | | |
| | | |
| | | |
| | | Specified Value | | |
| | | |
| | | LB3218 LB2518 LB2U16 LB2U12 LB16U8 LBMF16U8 | | |
| | | CBC3225 CBC2518 CBC2016 CBC2012 | | |
| | | Item | | | Test Methods and Remarks | | |
| | | LBC2518 LBC2016 LBC2012 | | CB2518 CB2016 CB2012 | | |
| | | | |
| | | LBR2518 LBR2012 | | |
| | | LEM2520 | | | CBL2012 | | LBM2016 | | |
| | | CBMF1608 | | |
| | | |
| | | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | 18.Thermalshock | | |
| | | Inductance change :Within±10% No significant abnormality in appearance. | | |
| | | nductance change Within±10% Q- R12~4R7 : 30min. 5R6~330 : 25min. 390~820 : 20min. 101 : 15min. | | |
| | | LEM : Conditions for Icycle | | |
| | | |
| | | |
| | | | | | | | | | | Step | Temperature (C) | Duration (min) | | | | 1 | -40 | 30 | | | | 2 | +85 | 30 | | | | | | | | | | |
| | | |
| | | |
| | | Number of cycle : 100 cycle Recovery : At least 1 hr of recovery the standard condition after the removal from test chamber, followed by measurement within 2 hrs. LB • LBC • LBR • CB • CBC • CBL • LBM ■ LBMF-CBMF : —40—h85°C, maintain times 30min. ,100 cycle Recovery : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. | | |
| | | |
| | | |
| | | 19.Damp heat | | Temperature : 60±2t Humidity : 90~95%RH Duration : 1000 hrs Recovery : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. | | |
| | | Inductance change :Within±10% No significant abnormality in appearance. | | |
| | | nductance change Within±10% Q- R12-4R7 : 30min. 5R6-330 : 25min. 390-820 : 20min. 101 : 15min. | | |
| | | |
| | | |
| | | |
| | | |
| | | 20.Loading under damp heat | | |
| | | Inductance change : Within±10% No significant abnormality in appearance. | | |
| | | nductance change Within±10% Q- R12-4R7 : 30min. 5R6-330 : 25min. 390-820 : 20min. 101 : 15min. | | | LEM • LB • LBC • CB • CBC • CBL • LBM ■ LBMF-CBMF : Temperature : 60±2t Humidity : 90~95°%RH Duration : 1000 hrs Applied current : Rated current Recovery : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. | | |
| | | |
| | | |
| | | |
| | | |
| | | 21.High temperature life test | | Inductance change :Within±10% No significant abnormality in appearance. | | |
| | | nductance change Within±10% Q- R12-4R7 : 30min. 5R6-330 : 25min. 390-820 : 20min. 101 : 15min. | | | LEM • CB • CBC • CBL • LBM • CBMF : Temperature : 85±2C Duration : 1000 hrs Recovery : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. | | |
| | | |
| | | |
| | | |
| | | |
| | | 22.Loading at high temperature | | |
| | | Inductance change :Within±10% No significant abnormality in appearance. | | |
| | | LB-LBC-LBR-LBMF : Temperature : 85±2Ï Duration : 1000 hrs Applied current : Rated current Recovery : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. | | |
| | | |
| | | |
| | | |
| | | 177 | | |
| | | TAIYO YUDEN 200S | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |