Specimen TablesTaber®Abraser MountingOptionsTest MaterialModelSpecimen Holder DescriptionSpecimen SizeTest Conditions Rigid, flatE100-125 Standard – test most rigid or flexible specimens 4” (100mm) square, orDry(use with E100-101 or 102 Hold Down Ring) 41 / 4 ” (108mm) diameter, with 1 / 4 ” (6.5mm) center hole* Rigid, flatE140-75 Rimmed – a 3 / 8 ” (9.5mm) raised rim retains liquids,4” (100mm) square, orWetallowing you to determine the effect of absorbed 5 1 / 2 ” (140mm) diameter, withand / or surface moisture on abrasion resistance 1 / 4 ” (6.5mm) center hole* Rigid, warpedE140-21 NEMA Threaded Ring – incorporates a clamp plate 4” (100mm) square, or 5 3 / 8 ”Dryand flanged clamp ring to test slightly warped (135mm) diameter, with 1 / 4 ” specimens, ring is threaded to the body of the (6.5mm) center hole* holder which secures the outer edges of the specimen Rigid, warpedE140-14 Ring Clamp – eight (8) screws spaced evenly on 5 3 / 8 ” (135mm) diameter, with 1 / 4 ”Wet or Drythe clamp plate allows you to test slightly warped (6.5mm) center hole* specimens; furnished with (S) or without (NS) center screw Rigid, squareE140-19 Drive-Pin Type – used for rigid, square specimens 4” (100mm) squareDrywithout the need for a center hole, attach specimens using S-37 or S-37-1 mounting sheets FlexibleE-3945 Multiple Specimen – divided into eight (8) sections, Cut to templateDryholder permits simultaneous testing of lightweight, flexible specimens FlexibleE140-15 Textile, Tensioning Type – incorporates a raised 5 1 / 4 ” (135mm) diameter, with 1 / 4 ”Drywear track to provide extra tensioning to the (6.5mm) center hole material when the hold down ring is drawn down over the edge of the holder and the clamp plate is mounted. FlexibleE140-18 Textile, Rimmed – provides an initial stretch to 6 1 / 4 ” (160mm) diameter, with 1 / 4 ”Wet or Drywoven fabrics, thereby minimizing the tendency (6.5mm) center hole to wrinkle if tested wet FlexibleE100-10 Transparent Plastic – enables textile specimens 5 1 / 4 ” (135mm) diameter, with 1 / 4 ”Dryto be viewed against a light source to determine (6.5mm) center hole wear characteristics without having to remove the specimen from the holder (use with E100-101 or 102 Hold Down Ring) FlexibleE100-101 Hold Down Ring – ID 4 1 / 4 ” (108mm) – for flexible materials up to 1 / 32 ” (0.8mm) thick FlexibleE100-102 Hold Down Ring – ID 4 5 / 16 ” (110mm) – for flexible materials up to 1 / 16 ” (1.5mm) thick S-21 Extension Nut – use when sample thickness is 1 / 4 ” (6.5mm) to 1 / 2 ” (12.5mm), requires 3 / 8 ” (9.525mm) center hole Notes: Use hold down ring and clamp plate for flexible specimens so vacuum does not lift specimen.* When using S-21 Extension Nut, center hole must be 3 / 8 ” (9.525mm). For more information: Call 1.800.333.5300 (U.S.) or 716.694.4000 (outside U.S.) Fax 716.694.1450 Email us at sales@taberindustries.comVisit us at www.taberindustries.com 455 Bryant StreetNorth Tonawanda, New York 14120 USA02/03 |
|