See other catalogues for
Taber Industries
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | Bonded Strain Gage Pressure Transducer | | |
| | | |
| | | 0-100 thru 0-10,000 PSI corresponding to an interval between 225 and 22,400 feet of sea water (68 and 6788 meters). Sea water exposed to 17 -4PH stainless steel. Other media cavity and case materials available upon request. 5.000 ±0.050 Vdc for a 50k ohm load or greater. Accuracy at any single temperature including linearity, hysteresis, and repeatability via RSS method within ±0.20% FSO. | | |
| | | Pressure Ranges Pressure Media Full Scale Output Accuracy | | |
| | | Triaxial Mechanical Shock Excitation | | 100 G's applied for 11 milliseconds will not cause change in performance characteristics. 20 to 36 Vdc unregulated. Reverse polarity protected. | | |
| | | |
| | | |
| | | Current Drain 20 mAdc typical. | | |
| | | |
| | | Signal Conditioning | | Integrated circuit DC isolated voltage regulator and DC amplifier providing high level-low output impedance signal electrically isolated from power source. Greater than 1000 megohms at 50 Vdc between all terminals in parallel and case at +70°F (+21°C). Greater than 1000 megohms at 50 Vdc from excitation to signal output leads at +70°F (+21°C). V NPT female. Options available. Submersible bulkhead connector receptacle type XSJ-5BCR with type XSJ-5CCP cable connector plug and 2 ft. cable pigtail. (Right angle CCP cable connector and special cable lengths available as options). Standard wiring: Excitation +1, -3; Signal +4, -5; No Connection 2. Approximately 45 ounces (1.3 Kg). | | |
| | | |
| | | |
| | | |
| | | Insulation | | |
| | | |
| | | | | | | | | | | | | | Resolution | Infinite. | | | | Resistance | | | | Natural | Range | Frequency | Range | Frequency | | | | | Frequency | | (kHz) | (PSI) | (kHz) | DC Isolation | | | | | 0-100 | 8 | 0-1000 | 39 | | | | | | 0-150 | 11 | 0-1500 | 48 | | | | | | 0-200 | 13 | 0-2000 | 50 | Pressure Fitting | | | | | 0-250 | 14 | 0-2500 | 62 | | | | | 0-300 | 15 | 0-3000 | 68 | Electrical | | | | | 0-400 | 20 | 0-5000 | 107 | Receptacle | | | | | 0-500 | 25 | 0-7500 | 132 | | | | | 0-750 | 31 | 0-10,000 | 152 | | | | | Proof Pressure | Application of 3 times | FS pressure | will not | | | | | | | | | | | | | | |
| | | |
| | | cause any change in performance characteristics. Burst Pressure Greater than 4.5 times FS pressure. | | |
| | | |
| | | Weight | | |
| | | |
| | | External Case Pressure Compensated Temperature Range Operating Temperature Range Thermal Sensitivity Shift Thermal Zero Shift Excitation | | 15,000 PSI maximum. | | |
| | | |
| | | -30°F to + 170°F (-34°C to +77°C). | | |
| | | |
| | | -65°F to +200°F (-54°C to +93°C). | | |
| | | |
| | | Less than ±0.005% FSO per °F over compensated temperature range (±0.009% FSO per °C). Less than ±0.010% FSO per °F over compensated temperature range. (±0.018% FSO per °C). 20 to 36 volts dc unregulated. Reverse polarity protected. ±100 volts 10 microsecond spikes will not cause permanent damage. | | |
| | | 455 Bryant Street North Tonawanda, New York 14120 USA Phone 1.800.333.5300 (U.S.) or 716.694.4000 (outside U.S.) Fax 716.694.1450 Email transducer@taberindustries.com Visit us at www.taberindustries.com TK05/02 | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |