Ocean Submersible/Oceanographic Pressure Transducers Model 2000 - Taber Industries - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for Taber Industries

Text version of the page
Bonded Strain Gage Pressure Transducer
0-100 thru 0-10,000 PSI corresponding to an interval between 225 and 22,400 feet of sea water (68 and 6788 meters).
Sea water exposed to 17 -4PH stainless steel. Other media cavity and case materials available upon request.
5.000 ±0.050 Vdc for a 50k ohm load or greater.
Accuracy at any single temperature including linearity, hysteresis, and repeatability via RSS method within ±0.20% FSO.
Pressure Ranges
Pressure Media
Full Scale Output
Accuracy
Triaxial
Mechanical
Shock
Excitation
100 G's applied for 11 milliseconds will not cause change in performance characteristics.
20 to 36 Vdc unregulated. Reverse polarity protected.
Current Drain 20 mAdc typical.
Signal
Conditioning
Integrated circuit DC isolated voltage regulator and DC amplifier providing high level-low output impedance signal electrically isolated from power source.
Greater than 1000 megohms at 50 Vdc between all terminals in parallel and case at +70°F (+21°C).
Greater than 1000 megohms at 50 Vdc from excitation to signal output leads at +70°F
(+21°C).
V NPT female. Options available.
Submersible bulkhead connector receptacle type XSJ-5BCR with type XSJ-5CCP cable connector plug and 2 ft. cable pigtail. (Right angle CCP cable connector and special cable lengths available as options). Standard wiring:
Excitation +1, -3; Signal +4, -5; No Connection 2.
Approximately 45 ounces (1.3 Kg).
Insulation
Resolution
Infinite.
Resistance
Natural
Range
Frequency
Range
Frequency
Frequency
(kHz)
(PSI)
(kHz)
DC Isolation
0-100
8
0-1000
39
0-150
11
0-1500
48
0-200
13
0-2000
50
Pressure Fitting
0-250
14
0-2500
62
0-300
15
0-3000
68
Electrical
0-400
20
0-5000
107
Receptacle
0-500
25
0-7500
132
0-750
31
0-10,000
152
Proof Pressure
Application of 3 times
FS pressure
will not
cause any change in performance characteristics.
Burst Pressure Greater than 4.5 times FS pressure.
Weight
External Case Pressure
Compensated
Temperature
Range
Operating
Temperature
Range
Thermal Sensitivity
Shift
Thermal Zero
Shift
Excitation
15,000 PSI maximum.
-30°F to + 170°F (-34°C to +77°C).
-65°F to +200°F (-54°C to +93°C).
Less than ±0.005% FSO per °F over compensated temperature range (±0.009% FSO per °C).
Less than ±0.010% FSO per °F over compensated temperature range. (±0.018% FSO per °C).
20 to 36 volts dc unregulated. Reverse polarity protected. ±100 volts 10 microsecond spikes will not cause permanent damage.
455 Bryant Street
North Tonawanda, New York 14120 USA
Phone 1.800.333.5300 (U.S.) or 716.694.4000 (outside U.S.)
Fax 716.694.1450
Email transducer@taberindustries.com
Visit us at www.taberindustries.com TK05/02