See other catalogues for
T-T ELECTRIC
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | IC06/17/37 | | |
| | | LAK 2112 MA | | |
| | | |
| | | |
| | | Base speed (min-1) at armature voltage (V) | | Armature circuit | | |
| | | |
| | | Max. | | |
| | | |
| | | Rated | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | Cont. | | | | | | armature | | elec. | Effici- | Resist- | Induc- | Code | | | | output | | | | | | current | Torque | speed** | ency | ance | tance | number | | | | (kW) | 260 | 400 | 440 | 460 | 500 | (A) | (Nm) | (min-1) | (%) | (Ohm) | (mH) | FR 154 | | | | 3.2 | | 1000 | | | | 12.2 | 31.0 | 1605 | 61.1 | 9.84 | 120 | 241-AB | | | | 3.7 | | | 1145 | | | 12.2 | 31.0 | 1605 | 64.1 | 9.84 | 120 | 241-AB | | | | 3.9 | | | | 1220 | | 12.2 | 31.0 | 1605 | 65.4 | 9.84 | 120 | 241-AB | | | | 4.4 | | | | | 1365 | 12.0 | 30.8 | 1605 | 67.8 | 9.84 | 120 | 241-AB | | | | 2.0 | 645 | | | | | 13.5 | 29.1 | 1960 | 50.3 | 7.78 | 88 | 241-BB | | | | 3.8 | | 1235 | | | | 13.5 | 29.3 | 1960 | 65.0 | 7.78 | 88 | 241-BB | | | | 4.3 | | | 1400 | | | 13.5 | 29.3 | 1960 | 67.5 | 7.78 | 88 | 241-BB | | | | 4.6 | | | | 1485 | | 13.5 | 29.3 | 1960 | 68.7 | 7.78 | 88 | 241-BB | | | | 5.0 | | | | | 1660 | 13.4 | 29.0 | 1960 | 70.9 | 7.78 | 88 | 241-BB | | | | 2.8 | 860 | | | | | 17.0 | 30.8 | 2480 | 57.4 | 5.14 | 61 | 241-CB | | | | 5.1 | | 1570 | | | | 17.0 | 30.8 | 2480 | 70.0 | 5.14 | 61 | 241-CB | | | | 5.7 | | | 1770 | | | 17.0 | 30.8 | 2480 | 72.2 | 5.14 | 61 | 241-CB | | | | 6.0 | | | | 1870 | | 17.0 | 30.8 | 2480 | 73.6 | 5.14 | 61 | 241-CB | | | | 6.6 | | | | | 2080 | 16.9 | 30.3 | 2480 | 75.0 | 5.14 | 61 | 241-CB | | | | 3.2 | 1010 | | | | | 18.5 | 30.2 | 3060 | 61.1 | 4.21 | 49 | 251-CB | | | | 5.7 | | 1795 | | | | 18.5 | 30.2 | 3060 | 61.1 | 4.21 | 49 | 251-CB | | | | 6.4 | | | 2015 | | | 18.5 | 30.2 | 3060 | 74.5 | 4.21 | 49 | 251-CB | | | | 6.7 | | | | 2130 | | 18.5 | 30.2 | 3060 | 75.3 | 4.21 | 49 | 251-CB | | | | 7.4 | | | | | 2355 | 18.0 | 30.0 | 3060 | 76.9 | 4.21 | 49 | 251-CB | | | | 3.8 | 1185 | | | | | 21.0 | 30.4 | 3250 | 64.4 | 3.33 | 39 | 241-DB | | | | 6.6 | | 2070 | | | | 21.0 | 30.4 | 3250 | 74.8 | 3.33 | 39 | 241-DB | | | | 7.4 | | | 2320 | | | 21.0 | 30.4 | 3250 | 76.5 | 3.33 | 39 | 241-DB | | | | 7.8 | | | | 2445 | | 21.0 | 30.4 | 3250 | 77.3 | 3.33 | 39 | 241-DB | | | | 8.5 | | | | | 2705 | 20.8 | 30.0 | 3250 | 78.8 | 3.33 | 39 | 241-DB | | | | 4.5 | 1445 | | | | | 23.7 | 30.0 | 3835 | 69.1 | 2.42 | 30 | 241-EB | | | | 7.7 | | 2450 | | | | 23.7 | 30.0 | 3835 | 77.9 | 2.42 | 30 | 241-EB | | | | 8.6 | | | 2740 | | | 23.7 | 30.0 | 3835 | 79.4 | 2.42 | 30 | 241-EB | | | | 9.1 | | | | 2885 | | 23.7 | 30.0 | 3835 | 80.1 | 2.42 | 30 | 241-EB | | | | 9.9 | | | | | 3175 | 23.6 | 29.2 | 3835 | 82.6 | 2.42 | 30 | 241-EB | | | | 5.8 | 1740 | | | | | 29.0 | 31.6 | 3595 | 72.3 | 1.75 | 30 | 231-EB | | | | 9.6 | | 2920 | | | | 29.0 | 31.5 | 3595 | 80.1 | 1.75 | 30 | 231-EB | | | | 10.7 | | | 3255 | | | 29.0 | 31.5 | 3595 | 81.4 | 1.75 | 30 | 231-EB | | | | 7.0 | 2175 | | | | | 34.0 | 30.8 | 3835 | 75.7 | 1.25 | 15 | 231-FB | | | | 11.5 | | 3590 | | | | 34.0 | 30.7 | 3835 | 82.3 | 1.25 | 15 | 231-FB | | | | 12.8 | | | 3995 | | | 34.0 | 30.7 | 3835 | 83.4 | 1.25 | 15 | 231-FB | | | | 8.7 | 2820 | | | | | 41.0 | 29.6 | 5000 | 79.0 | 0.85 | 10 | 231-GB1 | | | | 14.2 | | 4590 | | | | 41.0 | 29.6 | 5000 | 84.3 | 0.85 | 10 | 231-GB1 | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | ** Through field control with constant output. Please specify. Field loss (hot) = 420 W 1) Cooling air inlet at N-end. Can be used with cooling air inlet at D-end with 10% reduction of output. | | |
| | | |
| | | Data subject to change without prior notice. | | |
| | | |
| | | | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | |